- Frame size20 mm0.8 in
- Max airflow1.8 m³/h1 CFM
- Max static pressure21.2 Pa0.09 in. wg
- Voltage12 V
- Speed10,000 rpm
- Input power0.36 W
- Noise20.8 dB(A)
LWAD2010LL-05 DC Electronics Cooling Fan 20 mm
20 mm | DC | Max airflow 1.8 m³/h | Max static pressure 21.2 Pa | 20.8 dB(A)
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Dimensional drawing LWAD2010LL-05

Files for LWAD2010LL-05: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWAD2010LL-05
LWAD2010LL-05 is a LONGWELL DC Electronics Cooling Fan, frame 20 mm, rated 12 V DC, maximum airflow 1.8 m³/h, maximum static pressure 21.2 Pa, noise 20.8 dB(A), input power 0.36 W.
Technical data
| Model | LWAD2010LL-05 |
|---|---|
| Series | LWAD2010 |
| Motor type | DC |
| Rated voltage | 12 V |
| Current | 0.03 A |
| Input power | 0.36 W |
| Speed | 10,000 rpm |
| Max. airflow | 1.8 m³/h |
| Max. static pressure | 21.2 Pa |
| Noise | 20.8 dB(A) |
| Frame size | 20 mm |
Nameplate values; final selection is confirmed at the duty point and by project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWAD2010LL-05
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Alternatives with the same frame size (20 mm · DC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWAD2010LL-05 this model | 1.8 m³/h | 21.2 Pa | 10,000 rpm | 0.36 W | 20.8 dB(A) | 12 V | |
| LWAD2010LL-04 | 1.3 m³/h | 10.4 Pa | 7,000 rpm | 0.24 W | 20 dB(A) | 12 V | View |
| LWAD2010KL-04 | 1.3 m³/h | 10.4 Pa | 7,000 rpm | 0.2 W | 20 dB(A) | 5 V | View |
| LWAD2010KL-05 | 1.8 m³/h | 21.2 Pa | 10,000 rpm | 0.3 W | 20.8 dB(A) | 5 V | View |
| LWAD2010LM-06 | 1.9 m³/h | 26 Pa | 12,000 rpm | 0.6 W | 21.3 dB(A) | 12 V | View |
| LWAD2010KM-06 | 1.9 m³/h | 26 Pa | 12,000 rpm | 0.4 W | 21.3 dB(A) | 5 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWAD2010 seriesSame impeller, different speed grade or wiring
Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWAD2510LL-1125 mm · 2.1 m³/h · 21.4 Pa · DCadjacent size
LWAD2510KM-1125 mm · 3.4 m³/h · 43.9 Pa · DCadjacent size
LWAD2510KX-1325 mm · 5.1 m³/h · 78.3 Pa · DCadjacent size
LWAD2510LH-1325 mm · 4 m³/h · 72.3 Pa · DCadjacent size
LWAD2510KL-1025 mm · 2.1 m³/h · 21.4 Pa · DCadjacent size
LWAD2510LM-1225 mm · 3.4 m³/h · 43.9 Pa · DCadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
See all Cooling Fans & Blowers · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for cooling fans & blowers — on our main site.
Solutions
- Battery energy storageBESS containers and cabinets
- Data center coolingCRAH, FanGrid, server rooms
- Home appliance coolingHoods, ovens, dryers, air conditioners