DC Axial Cooling Fans

DC axial cooling fans, frame sizes 25–200 mm, for power supplies, cabinets, telecom and electronic equipment. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point627 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

DC Axial Cooling Fans — selection guide

DC Axial Cooling Fans: 627 models, frame sizes 25–200 mm, maximum airflow 2–1,141 m³/h, static pressure to 672 Pa, DC motors, across 32 series.

DC axial cooling fans are the 627-model core of the compact range: frames 25, 30, 40, 50, 60, 70, 80, 92, 120, 172 and 200 mm, thicknesses 10 to 60 mm, on 5, 12, 24 and 48 V. The busiest series are LWAD8025 (57 variants), LWAD12038 (48), LWAD9225 (42), LWAD8038 (36) and LWAD12025 (33) — the standard frames for power supplies, inverters and cabinets. Frames are UL94 V-0 plastic; ball-bearing versions are standard for continuous duty, sleeve-bearing versions available for cost-sensitive appliances.

The speed grade in the code (H / M / L, e.g. LWAD8025HL) trades airflow against noise within one frame; the technical data lists airflow, static pressure, current, speed and sound pressure for each.

How to select from this range

  1. Estimate airflow from heat load (Q ≈ 3 × W / ΔT), add grille and filter resistance, then choose the largest frame that fits at the lowest speed grade that clears the point.
  2. Use 48 V for telecom and server equipment, 24 V for industrial control, 12 V for appliances and PCs, 5 V for USB-powered devices.
  3. Specify PWM, tacho (FG) or alarm (RD) when ordering; they are part of the model code.
  4. Check L10 life at the real ambient: ratings are at 40 °C.

Where these fans are used

  • Switch-mode power supplies and UPS
  • Inverters and EV chargers
  • Telecom and server cabinets
  • Displays, projectors and appliances

Curves marked “measured” come from our own test rigs per AMCA 210 / ISO 5801 methods; digitised catalogue curves are flagged as such in the selector — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — DC Axial Cooling Fans

Which cooling fan frame is the most common?

80 × 25 mm (LWAD8025, 57 variants) and 120 × 38 mm (LWAD12038, 48 variants) — the standard power-supply and cabinet frames, in stock in all four voltages.

What is the difference between H, M and L speed grades?

Same frame and motor, different winding and speed: H gives the highest airflow and noise, L the lowest. A 92 × 25 mm fan spans roughly 60–200 m³/h across the grades.

Do you offer IP-rated cooling fans?

Yes, IP55 / IP68 versions with potted electronics are available on the 40–120 mm frames for outdoor and wash-down equipment; ask for the variant.

Related selections

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top