DC Centrifugal Blowers

DC centrifugal blowers with a concentrated discharge and higher static pressure, for directed cooling in tight spaces. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point179 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWFD12032HH-02 LWFD12032HH-02DC 120 mm 68.4 419 14.4 53.7 3,000 48 Details
LWFD12032HL-04 LWFD12032HL-04DC 120 mm 34.2 105 7.2 38.6 1,500 48 Details
LWFD12032HM-03 LWFD12032HM-03DC 120 mm 57 291 12 49.7 2,500 48 Details
LWFD12032HX-01 LWFD12032HX-01DC 120 mm 79.8 570 24 57 3,500 48 Details
LWFD12032LD-05 LWFD12032LD-05DC 120 mm 34.2 105 3.6 38.6 1,500 12 Details
LWFD12032LH-02 LWFD12032LH-02DC 120 mm 68.4 419 12 53.7 3,000 12 Details
LWFD12032LL-04 LWFD12032LL-04DC 120 mm 45.6 186 6 44.8 2,000 12 Details
LWFD12032LM-03 LWFD12032LM-03DC 120 mm 57 291 8.4 49.7 2,500 12 Details
LWFD12032LX-01 LWFD12032LX-01DC 120 mm 79.8 570 24 57 3,500 12 Details
LWFD12032MD-05 LWFD12032MD-05DC 120 mm 34.2 105 4.8 38.6 1,500 24 Details
LWFD12032MH-02 LWFD12032MH-02DC 120 mm 68.4 419 14.4 53.7 3,000 24 Details
LWFD12032ML-04 LWFD12032ML-04DC 120 mm 45.6 186 8.4 44.8 2,000 24 Details
LWFD12032MM-03 LWFD12032MM-03DC 120 mm 57 291 9.6 49.7 2,500 24 Details
LWFD12032MX-01 LWFD12032MX-01DC 120 mm 79.8 570 24 57 3,500 24 Details
LWFD4010KD-05 LWFD4010KD-05DC 40 mm 2.4 23 1 21.1 5,000 5 Details
LWFD4010KH-02 LWFD4010KH-02DC 40 mm 4.2 58 1.75 31.3 8,000 5 Details
LWFD4010KL-04 LWFD4010KL-04DC 40 mm 3 33 1.25 25.1 6,000 5 Details
LWFD4010KM-03 LWFD4010KM-03DC 40 mm 3.6 44 1.5 28.4 7,000 5 Details
LWFD4010KX-01 LWFD4010KX-01DC 40 mm 4.8 73 2 33.9 9,000 5 Details
LWFD4010LD-05 LWFD4010LD-05DC 40 mm 2.4 23 0.96 22.4 5,000 12 Details
LWFD4010LH-02 LWFD4010LH-02DC 40 mm 4.2 58 1.68 32.6 8,000 12 Details
LWFD4010LL-04 LWFD4010LL-04DC 40 mm 3 33 1.2 26.4 6,000 12 Details
LWFD4010LM-03 LWFD4010LM-03DC 40 mm 3.6 44 1.44 29.7 7,000 12 Details
LWFD4010LX-01 LWFD4010LX-01DC 40 mm 4.8 73 1.92 35.2 9,000 12 Details
LWFD4010MD-05 LWFD4010MD-05DC 40 mm 2.4 23 0.96 22.4 5,000 24 Details
LWFD4010MH-02 LWFD4010MH-02DC 40 mm 4.2 58 1.92 32.6 8,000 24 Details
LWFD4010ML-04 LWFD4010ML-04DC 40 mm 3 33 1.2 26.4 6,000 24 Details
LWFD4010MM-03 LWFD4010MM-03DC 40 mm 3.6 44 1.44 29.7 7,000 24 Details
LWFD4010MX-01 LWFD4010MX-01DC 40 mm 4.8 73 2.4 35.2 9,000 24 Details
LWFD5010KD-05 LWFD5010KD-05DC 50 mm 4.8 52 1 27.9 4,500 5 Details
LWFD5010KH-02 LWFD5010KH-02DC 50 mm 6 93 1.75 34.1 6,000 5 Details
LWFD5010KL-04 LWFD5010KL-04DC 50 mm 5.4 65 1.25 30.2 5,000 5 Details
LWFD5010KM-03 LWFD5010KM-03DC 50 mm 5.4 78 1.5 32.3 5,500 5 Details
LWFD5010KX-01 LWFD5010KX-01DC 50 mm 6.6 103 2 32.5 6,300 5 Details
LWFD5010LD-05 LWFD5010LD-05DC 50 mm 4.8 52 0.96 27.9 4,500 12 Details
LWFD5010LH-02 LWFD5010LH-02DC 50 mm 6 93 1.92 34.1 6,000 12 Details
LWFD5010LL-04 LWFD5010LL-04DC 50 mm 5.4 65 1.2 30.2 5,000 12 Details
LWFD5010LM-03 LWFD5010LM-03DC 50 mm 5.4 78 1.44 32.3 5,500 12 Details
LWFD5010LX-01 LWFD5010LX-01DC 50 mm 6.6 103 2.4 35.2 6,300 12 Details
LWFD5010MD-05 LWFD5010MD-05DC 50 mm 4.8 52 0.96 27.9 4,500 24 Details

DC Centrifugal Blowers — selection guide

DC Centrifugal Blowers: 179 models, frame sizes 40–120 mm, maximum airflow 2–79 m³/h, static pressure to 570 Pa, DC motors, across 12 series. 150 of them carry a measured P-Q curve and 179 a dimensional drawing.

DC centrifugal blowers (LWFD) push air through a narrow outlet at higher static pressure than an axial fan of the same size: frames Ø40, 50, 60, 75, 97 and 120 mm (LWFD4010 to LWFD12032), 2.4–80 m³/h at 23–570 Pa, on 5 / 12 / 24 / 48 V. Each frame has 14–15 variants across voltages and speed grades. They are the fans for ducted cooling paths — heatsinks, battery packs, laser and medical modules, respiratory devices — where the air has to be directed rather than blown across an enclosure.

How to select from this range

  1. Use a blower where the air path has significant resistance (heatsink fins, ducts, filters); an axial fan stalls there.
  2. Match the outlet size and direction to the duct; blowers are handed.
  3. Choose the frame by pressure need: Ø75–120 mm reach 400–570 Pa, Ø40–60 mm 200–400 Pa.

Where these fans are used

  • Heatsink and duct cooling in electronics
  • Battery packs and chargers
  • Medical and respiratory devices
  • Laser and optical modules

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — DC Centrifugal Blowers

When should I use a DC blower instead of an axial fan?

When the air must pass through a channel with resistance — a finned heatsink, a duct, a filter — a blower keeps airflow where an axial fan of the same size would stall. At free air the axial fan moves more.

Which blower frames are ETL listed?

The DC centrifugal blower line is ETL listed (Intertek control no. 5022563) to UL 507 / CSA C22.2 No. 113 for 12 / 24 / 48 V.