• Frame size120 mm4.7 in
  • Max airflow45.5 m³/h27 CFM
  • Max static pressure171.2 Pa0.69 in. wg
  • Voltage48 V
  • Speed2,300 rpm
  • Input power7.2 W
  • Noise48 dB(A)

LWFD12032HM-07 DC Centrifugal Blower 120 mm

120 mm | DC | Max airflow 45.5 m³/h | Max static pressure 171.2 Pa | 48 dB(A)

  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWFD12032HM-072 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Dimensional drawing LWFD12032HM-07

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWFD12032HM-07 Dimensional drawing

Files for LWFD12032HM-07: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWFD12032HM-07

LWFD12032HM-07 is a LONGWELL DC Centrifugal Blower, frame 120 mm, rated 48 V DC, maximum airflow 45.5 m³/h, maximum static pressure 171.2 Pa, noise 48 dB(A), input power 7.2 W.

Technical data

Model LWFD12032HM-07
Series LWFD12032
Motor type DC
Rated voltage 48 V
Current 0.15 A
Input power 7.2 W
Speed 2,300 rpm
Max. airflow 45.5 m³/h
Max. static pressure 171.2 Pa
Noise 48 dB(A)
Frame size 120 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWFD12032HM-07

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same frame size (120 mm · DC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWFD12032HM-07 this model 45.5 m³/h171.2 Pa 2,300 rpm7.2 W48 dB(A)48 V
LWFD12032ML-09 41.9 m³/h137.3 Pa 2,100 rpm5.76 W46 dB(A)24 V View
LWFD12032LL-09 41.9 m³/h137.3 Pa 2,100 rpm5.4 W46 dB(A)12 V View
LWFD12032MM-10 45.5 m³/h171.2 Pa 2,300 rpm7.2 W48 dB(A)24 V View
LWFD12032LM-10 45.5 m³/h171.2 Pa 2,300 rpm7.56 W48 dB(A)12 V View
LWFD12032MH-11 49.2 m³/h206.9 Pa 2,500 rpm8.64 W50.5 dB(A)24 V View
LWFD12032ML-08BB 52.2 m³/h207.9 Pa 2,500 rpm9.6 W45 dB(A)24 V View
LWFD12032LL-08B 52.2 m³/h207.9 Pa 2,500 rpm8.4 W45 dB(A)12 V View
LWFD12032MH-12 55 m³/h264.3 Pa 2,800 rpm12 W53.5 dB(A)24 V View
LWFD12032LH-12 55 m³/h264.3 Pa 2,800 rpm13.2 W53.5 dB(A)12 V View
LWFD12032MM-07B 60 m³/h291.94 Pa 3,000 rpm16.8 W51 dB(A)24 V View
LWFD12032LM-07B 60 m³/h291.94 Pa 3,000 rpm12 W51 dB(A)12 V View
LWFD12032MX-13 61.2 m³/h358.9 Pa 3,100 rpm15.12 W56 dB(A)24 V View
LWFD12032LX-13 61.2 m³/h358.9 Pa 3,100 rpm15 W56 dB(A)12 V View
LWFD12032MH-06B 70.2 m³/h461.99 Pa 3,500 rpm24 W57 dB(A)24 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for cooling fans & blowers — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote