- ImpellerØ70 mm2.8 in
- Max airflow79,200 m³/h46,616 CFM
- Voltage220 V
- Speed2,000 rpm
- Input power70 W
LWGA70S-01 AC Gas Burner Blower Ø70 mm
Ø70 mm | AC | Max airflow 79,200 m³/h
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Dimensional drawing LWGA70S-01

Files for LWGA70S-01: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWGA70S-01
LWGA70S-01 is a LONGWELL AC Gas Burner Blower, impeller Ø70 mm, rated 220 V AC, maximum airflow 79,200 m³/h, input power 70 W.
Technical data
| Model | LWGA70S-01 |
|---|---|
| Series | LWGA70 |
| Motor type | AC |
| Rated voltage | 220 V |
| Frequency | 50 Hz |
| Current | 585 A |
| Input power | 70 W |
| Speed | 2,000 rpm |
| Max. airflow | 79,200 m³/h |
| Impeller diameter | Ø70 mm |
Nameplate values; final selection is confirmed at the duty point and by project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWGA70S-01
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWGE077S-01Ø77 mm · 87 m³/h · 2,350 Pa · ECadjacent size
LWGA60S-01Ø60 mm · 59,400 m³/h · ACadjacent size
LWGA085S-01Ø85 mm · 103 m³/h · 185 Pa · ACadjacent size
LWGA085S-02Ø85 mm · 101 m³/h · 185 Pa · ACadjacent size
LWGA085S-03Ø85 mm · 100 m³/h · 185 Pa · ACadjacent size
LWGA53S-01Ø53 mm · 66,600 m³/h · ACadjacent sizeSee all Gas Blowers · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for gas blowers — on our main site.