Select the right fan by duty point — from 2,600 LONGWELL models

Enter airflow and static pressure and get every model whose measured P-Q curve covers your operating point, ranked by pressure margin. Then download the drawing, curve and datasheet, and send an RFQ straight to the factory.

Measured wind-tunnel curvesDrawings, curves & datasheets per modelFactory RFQ, reply within 1 business dayISO 9001 · ETL · CE · RoHS

Know your airflow and static pressure? Get matching models instantly from 2,397 fans.

Every model with a measured P-Q curve is checked at your duty point: is the point under the curve, and how much static pressure margin remains? The ideal margin is 10–25% — too little and a dirty filter stalls the fan; too much and the fan runs off its efficient range.

76 models meet 6,000 m³/h @ 250 Pa (3,531 CFM @ 1.00 in. wg) 63 with a curve in the library · 13 estimated from nameplate data · top 40 shown Air power at this point 417 WQ × Δp — no fan can draw less than this
00 2059309 4118618 6176927 82351236 102941545 Airflow m³/hStatic pressure Pa 6000 m³/h / 250 Pa
LWBE3G560-188PT-08LWBE3G560-188NT-14LWBE3G450-188NT-21LWBE3G630-188NT-07LWBE3G500-138PT-08LWBE3G500-138NT-13LWBE3G355-188NT-26LWBE3G450-102NT-20solid = wind-tunnel measured · dashed = digitised catalogue curve
CompareModelMatchSpeed gradePressure at pointPaMarginMax airflowm³/hPowerW · nameplateNoisedB(A)VoltageVSizemmDataActions
LWBE3G560-188PT-08EC 100 Grade 66 grades · 5 in reserve 273 9% 19,7604,70091400560 Digitised Curve Datasheet
LWBE3G560-188NT-14EC 100 874 rpm6 grades · 5 in reserve 272.8 9% 19,7604,70091380560 Digitised Curve Datasheet
LWBE3G450-188NT-21EC 100 1,560 rpm4 grades · 3 in reserve 277 11% 12,6474,60096380450 Digitised Curve Datasheet
LWBE3G630-188NT-07EC 99.6 Grade 33 grades · 2 in reserve 269.3 8%tight 21,1002,95585400630 Digitised Curve Datasheet
LWBE3G500-138PT-08EC 99.4 Grade 1Highest grade, no reserve 279.6 12% 8,13787071400500 Digitised Curve Datasheet
LWBE3G500-138NT-13EC 99.1 Grade 1Highest grade, no reserve 281.6 13% 8,13787071400500 Digitised Curve
LWBE3G355-188NT-26EC 98.7 Grade 1Highest grade, no reserve 273.8 10% 8,0343,09096400355 Digitised Curve Datasheet
LWBE3G450-102NT-20EC 98.7 1,624 rpmHighest grade, no reserve 284.7 14% 8,6521,10093380450 Digitised Curve Datasheet
LWBE3G400-138NT-12EC 98.2 Grade 1Single grade 288.8 16% 7,4591,48071400400 Digitised Curve Datasheet
LWBE3G400-138PT-04EC 98.1 Grade 1Single grade 289.4 16% 7,4591,10077400400 Digitised Curve Datasheet
LWBE3G450-138NT-08EC 94.3 1,600 rpm9 grades · 1 in reserve 317 27% 7,82891075400450 Digitised Curve Datasheet
LWBE3G630-188PT-05EC 94 Grade 33 grades · 2 in reserve 334.4 34% 19,1583,60085400630 Digitised Curve Datasheet
LWBE3G560-188NT-10EC 88.7 1,000 rpm9 grades · 5 in reserve 343.8 38% 14,8792,42085400560 Digitised Curve Datasheet
LWAE3G800TS-5PKW-03EC 87.8 Grade 1Single grade 335.2 34% 24,8921,58978380/400800 Digitised Curve Datasheet
LWAE3G900TS-5MGW-01EC 87.3 10 VSingle grade 263.6 5%tight 32,3132,78585380900 Digitised Curve Datasheet
LWBA4D500-188NT-01AC 81.4 Grade 1Single grade 355 42% 8,0341,00079380500 Digitised Curve Datasheet
LWBE3G355-138PT-05EC 78 8 VHighest grade, no reserve 365.5 46% 7,0451,70081400355 Digitised Curve Datasheet
LWBA6D630-188NT-01AC 78 Grade 1Single grade 365.6 46% 12,3601,50080380630 Digitised Datasheet
LWBE3G500-188NT-14EC 74.7 1,500 rpm9 grades · 4 in reserve 385.3 54% 10,3051,90072400500 Digitised Curve
LWBE3G500-188NT-10EC 74.7 1,500 rpm9 grades · 4 in reserve 385.3 54% 13,4724,20066400500 Digitised Curve Datasheet
LWBE3G450-188NT-17EC 74.3 2,140 rpm9 grades · 3 in reserve 384.3 54% 8,6612,59585400450 Digitised Curve Datasheet
LWBE3G560-188PT-01EC 72.2 8 V2 grades · 1 in reserve 402.4 61% 16,0393,300n/a400560 Digitised Curve Datasheet
LWBE3G630-188NT-09EC 71.2 1,000 rpm5 grades · 4 in reserve 405.6 62% 21,7425,60075400630 Digitised Curve Datasheet
LWAE3G450ST-5MEW-08EC 66.6 Grade 1Highest grade, no reserve 401.3 61% 6,38644568220/230450 Digitised Curve Datasheet
LWAE3G450SS-5MEW-07EC 66.6 Grade 1Highest grade, no reserve 401.3 61% 6,38644568220/230450 Digitised Curve Datasheet
LWBE3G450-188PT-16EC 65.5 Grade 1Single grade 404.7 62% 8,9852,400n/a400450 Digitised Curve Datasheet
LWBE3G560-188PT-02EC 65.4 Grade 46 grades · 3 in reserve 416.3 67% 16,4802,77081400560 Digitised Curve Datasheet
LWBE3G560-188NT-09EC 65.4 1,026 rpm6 grades · 3 in reserve 416.3 67% 16,4802,77081400560 Digitised Curve Datasheet
LWBE3G450-138PT-04EC 56.7 Grade 22 grades · 1 in reserve 451.1 80% 7,82891079400450 Digitised Curve Datasheet
LWBE3G630-188NT-06EC 56.4 Grade 23 grades · 1 in reserve 442.6 77% 19,2472,19566400630 Digitised Curve Datasheet
LWBA4D500-188NT-02AC 52.4 Grade 1Single grade 445.6 78% 9,7851,50080380500 Digitised Datasheet
LWBE3G500-188PT-04EC 52 Grade 1Highest grade, no reserve 446.9 79% 14,2143,00089400500 Digitised Curve Datasheet
LWBE3G560-188NT-01EC 51.8 Grade 23 grades · 1 in reserve 456.8 83% 16,0393,30063400560 Digitised Curve Datasheet
LWBA4D500-188NT-05AC 50 Grade 1Single grade 453.1 81% 9,3771,30081.9380500 Digitised Curve Datasheet
LWBE3G630-188PT-02EC 47.8 8 V2 grades · 1 in reserve 478.7 91% 21,1002,955n/a400630 Digitised Curve Datasheet
LWFA-E-450-02AC 44.7 Grade 1Single grade 469.5 88% 10,500n/a80n/a450 Digitised Curve
LWBE3G450-188NT-22EC 41.2 Grade 36 grades · 2 in reserve 488.1 95% 10,7522,40092380450 Digitised Curve Datasheet
LWFA-E-500-02AC 41 Grade 22 grades · 1 in reserve 680.4 172% 11,000n/a82n/a500 Digitised
LWFA-E-500-01AC 41 Grade 22 grades · 1 in reserve 635.6 154% 8,380n/a75n/a500 Digitised
LWFE3G355-188DS-01EC 41 Grade 33 grades · 2 in reserve 560.3 124% 8,7991,70081380355 Digitised

“Measured” = wind-tunnel test data; “Digitised” = read from the catalogue curve, for pre-selection; “Estimated” = no curve in the library yet — the pressure at your airflow is estimated from the nameplate maxima with a conservative straight-line curve, so ask for the measured curve before finalising. Power, noise and max airflow are nameplate values, not values at your duty point. Final selection is subject to duty-point verification and engineering confirmation.

Know the fan type you need? Enter the category and see its full parameter range.

Only know the application? Pick it below — each duty point is pre-verified against the library.

Not sure what airflow and static pressure to enter? Pick the closest application — every duty point below returns matching models from our measured library.

2,616models
Ø24–1,000impeller size, mm
0–61kairflow, m³/h
849measured P-Q curves
2,316dimensional drawings

Browse by product line

Every category page is a selector for that fan type: filter by airflow, static pressure, voltage, size and motor, then compare in the data table.

Axial FansAxial Fans435 models

High airflow, low–medium pressure: condensers, heat pumps, ventilation

Cross Flow FansCross Flow Fans318 models

Even linear discharge, low noise: indoor AC units, air curtains

Commercial Centrifugal BlowersCommercial Centrifugal Blowers26 models

DD direct drive and LWFA series for kitchens and ventilation units

Gas BlowersGas Blowers56 models

Burner and boiler air supply, premix and forced draft

Explosion-Proof FansExplosion-Proof Fans31 models

Ex-rated axial and centrifugal fans for hazardous areas

Poultry & Livestock FansPoultry & Livestock Fans30 models

Tunnel and minimum ventilation for barns and greenhouses

Motor Cooling FansMotor Cooling Fans30 models

Forced cooling for VFD-driven motors

Rail Transit FansRail Transit Fans11 models

Vehicle and platform ventilation

Exhaust FansExhaust Fans13 models

Wall and roof exhaust, floor dryers

Anti-Corrosion Fans4 models

PP / FRP fans for corrosive and humid air

How selection works here

Three steps from duty point to quotation — no login, no spreadsheet.

1Enter the duty pointAirflow and static pressure at the design condition. Use the application presets if you only know the use case.
2Check the curveEach result shows the speed grade that meets the point, the available pressure and the margin. 10–25% margin is ideal.
3Get files and quoteDownload the dimensional drawing, P-Q curve and datasheet. Add models to the RFQ list and submit once — an engineer replies within 1 business day.

Why buyers specify LONGWELL

Ningbo Longwell Electric Technology — HVACR fans and motors since 1990, exporting to 30+ countries.

The data is measured, not scaled

Six in-house laboratories produce every curve and noise figure on this site. Third-party test reports on request.

Certificates you can verify by number

Management systems and product compliance per product line; scans of every original are on the certifications page.

Since 1990Ningbo Longwell Electric Technology Co., Ltd. — HVACR fans & motors, 36 years
30+ countriesOEM / ODM partner; offices in Russia (2022), Türkiye (2023) and Poland (2024)
2,616 models849 measured P-Q curves, drawings and datasheets online
Samples 1–3 daysproduction batches 15–30 days ex works Ningbo
Reply in 1 business dayengineer-checked quotation with curve and lead time

See the test labs, core technology and all certificate scans →

Send us the duty point and we do the selection

Airflow, static pressure, voltage, control mode and quantity — that is all our engineers need to propose the best-fit model with curve and lead time.

Ask an engineer   Download center
Scroll to Top
RFQ list