Exhaust Fans

Exhaust and ventilation fans for bathrooms, kitchens, workshops and basements, including floor dryers and solar roof fans. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point13 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWF-100-01A LWF-100-01AAC Ø29 mm see curve 100 220 Details
LWF-1000-02A LWF-1000-02AAC Ø47 mm see curve 1,000 220 Details
LWF-1000-03A LWF-1000-03AAC Ø40 mm see curve 1,000 220 Details
LWF-1000-04B LWF-1000-04BAC Ø47 mm see curve 1,000 220 Details
LWF-1100-01B LWF-1100-01BAC Ø50 mm see curve 1,100 220 Details
LWF-1300-01B LWF-1300-01BAC see curve 1,000 79 1,480 220 Details
LWF-1300-02B LWF-1300-02BAC see curve 1,000 79 1,480 220 Details
LWF-300-01A LWF-300-01AAC 61,200 see curve 300 62 1,280 220 Details
LWF-300-02A LWF-300-02AAC Ø32 mm see curve 300 220 Details
LWF-3200-01B LWF-3200-01BAC see curve 3,200 80 1,480 220 Details
LWF-3200-02B LWF-3200-02BAC Ø43 mm see curve 3,200 220 Details
LWHB-01 LWHB-01AC see curve 450 2,800 21 Details
LWHB-02 LWHB-02AC 216 see curve 15,000 21 Details

Exhaust Fans — selection guide

The Exhaust Fans category currently lists 13 models, impellers Ø29–50 mm, maximum airflow 216–61,200 m³/h, on AC motors, across 2 series. Common voltages: 220 V, 21 V.

Exhaust fans for bathrooms, kitchens, workshops and warehouses, plus floor dryers and portable blowers: simple, robust axial and centrifugal units for wall, window or roof mounting.

How to select a Exhaust Fan

  1. Size by room volume and air-change rate; add resistance for louvres and ducts.
  2. Choose shutter type and IP rating for outdoor or wet locations.

Typical applications

  • Bathrooms and kitchens
  • Workshops and garages
  • Warehouses and basements

Why specify LONGWELL exhaust fans

Every model here is a current production item with structured data — not a catalogue scan. Curves are tested on our own wind-tunnel rigs per AMCA 210 / ISO 5801 methods, drawings and datasheets download directly, CAD is released on request, and a quotation with the duty-point check comes back within one business day. Samples ship in 1–3 days and production batches in 15–30 days from the factory in Ningbo, with ISO 9001 / 14001 / 45001 management systems and ETL, CE and RoHS documentation per product line.

FAQs — Exhaust Fans

How do I size an exhaust fan?

Multiply room volume by the required air changes per hour to get airflow, then choose a model whose curve covers that airflow at the louvre resistance.

Related selections

Scroll to Top
RFQ list