Select the right fan by duty point — from 2,600 LONGWELL models

Enter airflow and static pressure and get every model whose measured P-Q curve covers your operating point, ranked by pressure margin. Then download the drawing, curve and datasheet, and send an RFQ straight to the factory.

Measured wind-tunnel curvesDrawings, curves & datasheets per modelFactory RFQ, reply within 1 business dayISO 9001 · ETL · CE · RoHS

Know your airflow and static pressure? Get matching models instantly from 2,397 fans.

Every model with a measured P-Q curve is checked at your duty point: is the point under the curve, and how much static pressure margin remains? The ideal margin is 10–25% — too little and a dirty filter stalls the fan; too much and the fan runs off its efficient range.

9 models meet 15,000 m³/h @ 300 Pa Air power at this point 1250 WQ × Δp — no fan can draw less than this
00 4221245 8441491 12662736 16882982 211031227 Airflow m³/hStatic pressure Pa 15000 m³/h / 300 Pa
LWBE3G630-188PT-01LWBE3G630-188NT-06LWBE3G630-188NT-09LWBE3G630-188NT-07LWBE3G630-188PT-05LWBE3G630-188PT-02LWBE3G560-188PT-08LWBE3G560-188NT-14solid = wind-tunnel measured · dashed = digitised catalogue curve
CompareModelMatchSpeed gradePressure at pointPaMarginMax airflowm³/hPowerW · nameplateNoisedB(A)VoltageVSizemmDataActions
LWBE3G630-188PT-01EC 89.9 10 VHighest grade, no reserve 394.3 31% 19,2472,195n/a400630 Digitised Curve Datasheet
LWBE3G630-188NT-06EC 86.5 Grade 1Highest grade, no reserve 315.5 5%tight 19,2472,19566400630 Digitised Curve Datasheet
LWBE3G630-188NT-09EC 78.3 1,400 rpm5 grades · 2 in reserve 303.6 1%tight 21,7425,60075400630 Digitised Curve Datasheet
LWBE3G630-188NT-07EC 66.8 Grade 1Highest grade, no reserve 480.8 60% 21,1002,95585400630 Digitised Curve Datasheet
LWBE3G630-188PT-05EC 64.6 10 VHighest grade, no reserve 489.1 63% 19,1583,60085400630 Digitised Curve Datasheet
LWBE3G630-188PT-02EC 48.7 10 VHighest grade, no reserve 548.6 83% 21,1002,955n/a400630 Digitised Curve Datasheet
LWBE3G560-188PT-08EC 36.2 4 V6 grades · 1 in reserve 656.3 119% 19,7604,70091400560 Digitised Curve Datasheet
LWBE3G560-188NT-14EC 36.2 1,700 rpm6 grades · 1 in reserve 656 119% 19,7604,70091380560 Digitised Curve Datasheet
LWBE3G630-188PT-04EC 35 Grade 1Single grade 899.7 200% 21,7425,600n/a400630 Digitised Curve Datasheet

“Measured” = wind-tunnel test data; “Digitised” = read from the catalogue curve, for pre-selection. Power, noise and max airflow are nameplate values, not values at your duty point. Final selection is subject to duty-point verification and engineering confirmation.

Know the fan type you need? Enter the category and see its full parameter range.

Only know the application? Pick it below — each duty point is pre-verified against the library.

Not sure what airflow and static pressure to enter? Pick the closest application — every duty point below returns matching models from our measured library.

2,616models
Ø24–1,000impeller size, mm
0–61kairflow, m³/h
849measured P-Q curves
2,316dimensional drawings

Browse by product line

Every category page is a selector for that fan type: filter by airflow, static pressure, voltage, size and motor, then compare in the data table.

Axial FansAxial Fans435 models

High airflow, low–medium pressure: condensers, heat pumps, ventilation

Cross Flow FansCross Flow Fans318 models

Even linear discharge, low noise: indoor AC units, air curtains

Commercial Centrifugal BlowersCommercial Centrifugal Blowers26 models

DD direct drive and LWFA series for kitchens and ventilation units

Gas Blowers56 models

Burner and boiler air supply, premix and forced draft

Explosion-Proof Fans31 models

Ex-rated axial and centrifugal fans for hazardous areas

Poultry & Livestock FansPoultry & Livestock Fans30 models

Tunnel and minimum ventilation for barns and greenhouses

Motor Cooling FansMotor Cooling Fans30 models

Forced cooling for VFD-driven motors

Rail Transit FansRail Transit Fans11 models

Vehicle and platform ventilation

Exhaust FansExhaust Fans13 models

Wall and roof exhaust, floor dryers

Anti-Corrosion Fans4 models

PP / FRP fans for corrosive and humid air

How selection works here

Three steps from duty point to quotation — no login, no spreadsheet.

1Enter the duty pointAirflow and static pressure at the design condition. Use the application presets if you only know the use case.
2Check the curveEach result shows the speed grade that meets the point, the available pressure and the margin. 10–25% margin is ideal.
3Get files and quoteDownload the dimensional drawing, P-Q curve and datasheet. Add models to the RFQ list and submit once — an engineer replies within 1 business day.

Why buyers specify LONGWELL

Ningbo Longwell Electric Technology — HVACR fans and motors since 1990, exporting to 30+ countries.

The data is measured, not scaled

Six in-house laboratories produce every curve and noise figure on this site. Third-party test reports on request.

Certificates you can verify by number

Management systems and product compliance per product line; scans of every original are on the certifications page.

Since 1990Ningbo Longwell Electric Technology Co., Ltd. — HVACR fans & motors, 36 years
30+ countriesOEM / ODM partner; offices in Russia (2022), Türkiye (2023) and Poland (2024)
2,616 models849 measured P-Q curves, drawings and datasheets online
Samples 1–3 daysproduction batches 15–30 days ex works Ningbo
Reply in 1 business dayengineer-checked quotation with curve and lead time

See the test labs, core technology and all certificate scans →

Send us the duty point and we do the selection

Airflow, static pressure, voltage, control mode and quantity — that is all our engineers need to propose the best-fit model with curve and lead time.

Ask an engineer   Download center
Scroll to Top
RFQ list