Select the right fan by duty point — from 2,600 LONGWELL models

Enter airflow and static pressure and get every model whose measured P-Q curve covers your operating point, ranked by pressure margin. Then download the drawing, curve and datasheet, and send an RFQ straight to the factory.

Measured wind-tunnel curvesDrawings, curves & datasheets per modelFactory RFQ, reply within 1 business dayISO 9001 · ETL · CE · RoHS

Know your airflow and static pressure? Get matching models instantly from 2,397 fans.

Every model with a measured P-Q curve is checked at your duty point: is the point under the curve, and how much static pressure margin remains? The ideal margin is 10–25% — too little and a dirty filter stalls the fan; too much and the fan runs off its efficient range.

46 models meet 8,000 m³/h @ 300 Pa (4,709 CFM @ 1.20 in. wg) 39 with a curve in the library · 7 estimated from nameplate data · top 40 shown Air power at this point 667 WQ × Δp — no fan can draw less than this
00 2643232 5287464 7930696 10574928 132171160 Airflow m³/hStatic pressure Pa 8000 m³/h / 300 Pa
LWBE3G560-188PT-01LWBE3G630-188NT-09LWBE3G560-188NT-01LWBE3G500-188NT-14LWBE3G500-188NT-10LWBE3G450-188NT-22LWBE3G560-188PT-08LWBE3G630-188NT-06solid = wind-tunnel measured · dashed = digitised catalogue curve
CompareModelMatchSpeed gradePressure at pointPaMarginMax airflowm³/hPowerW · nameplateNoisedB(A)VoltageVSizemmDataActions
LWBE3G560-188PT-01EC 100 8 V2 grades · 1 in reserve 334.8 12% 16,0393,300n/a400560 Digitised Curve Datasheet
LWBE3G630-188NT-09EC 100 1,000 rpm5 grades · 4 in reserve 325.1 8% 21,7425,60075400630 Digitised Curve Datasheet
LWBE3G560-188NT-01EC 100 Grade 23 grades · 1 in reserve 349.7 17% 16,0393,30063400560 Digitised Curve Datasheet
LWBE3G500-188NT-14EC 100 1,700 rpm9 grades · 3 in reserve 338.7 13% 10,3051,90072400500 Digitised Curve
LWBE3G500-188NT-10EC 100 1,700 rpm9 grades · 3 in reserve 338.7 13% 13,4724,20066400500 Digitised Curve Datasheet
LWBE3G450-188NT-22EC 94.8 Grade 26 grades · 1 in reserve 380.2 27% 10,7522,40092380450 Digitised Curve Datasheet
LWBE3G560-188PT-08EC 92.3 Grade 56 grades · 4 in reserve 403.3 34% 19,7604,70091400560 Digitised Curve Datasheet
LWBE3G630-188NT-06EC 92.1 Grade 23 grades · 1 in reserve 397 32% 19,2472,19566400630 Digitised Curve Datasheet
LWBE3G560-188NT-14EC 92.1 1,090 rpm6 grades · 4 in reserve 403.7 35% 19,7604,70091380560 Digitised Curve Datasheet
LWFA-E-450-02AC 92 Grade 1Single grade 386.2 29% 10,500n/a80n/a450 Digitised Curve
LWBE3G560-188PT-02EC 90.8 Grade 46 grades · 3 in reserve 316.3 5%tight 16,4802,77081400560 Digitised Curve Datasheet
LWBE3G560-188NT-09EC 90.7 1,026 rpm6 grades · 3 in reserve 316.2 5%tight 16,4802,77081400560 Digitised Curve Datasheet
LWFA6D500-188NT-01AC 87.5 Grade 1Single grade 316.6 6%tight 9,0644,40075380500 Digitised Curve
LWFE3G315-188DS-01EC 86.6 Grade 1Highest grade, no reserve 406.6 36% 8,7322,40081380315 Digitised
LWBE3G630-188NT-07EC 86 Grade 23 grades · 1 in reserve 419.9 40% 21,1002,95585400630 Digitised Curve Datasheet
LWBE3G560-188NT-10EC 82.2 1,220 rpm9 grades · 3 in reserve 431.4 44% 14,8792,42085400560 Digitised Curve Datasheet
LWBE3G630-188PT-02EC 81.7 8 V2 grades · 1 in reserve 447.3 49% 21,1002,955n/a400630 Digitised Curve Datasheet
LWBE3G500-188NT-08EC 78.8 Grade 23 grades · 1 in reserve 446.9 49% 14,2143,00089400500 Digitised Curve Datasheet
LWBE3G500-188NT-09EC 78.8 Grade 23 grades · 1 in reserve 446.9 49% 12,2433,16078400500 Digitised Curve
LWBE3G500-188PT-07EC 76.9 10 VSingle grade 442.7 48% 10,3051,900n/a400500 Digitised Curve Datasheet
LWAE3G800TS-5PKW-03EC 76.7 Grade 1Single grade 305 2%tight 24,8921,58978380/400800 Digitised Curve Datasheet
LWFE3G355-188DS-01EC 62.5 Grade 23 grades · 1 in reserve 508 69% 8,7991,70081380355 Digitised
LWBE3G630-188PT-05EC 56.3 Grade 23 grades · 1 in reserve 531.4 77% 19,1583,60085400630 Digitised Curve Datasheet
LWBA4D560-188NT-05AC 49.5 Grade 1Single grade 545.5 82% 13,1251,98083.9380560 Digitised Curve Datasheet
LWBE3G450-188PT-09EC 46.8 Grade 1Single grade 555.7 85% 8,6612,595n/a400450 Digitised Curve Datasheet
LWBE3G450-188NT-17EC 44.4 2,800 rpmHighest grade, no reserve 564.7 88% 8,6612,59585400450 Digitised Curve Datasheet
LWFA-E-500-02AC 41 Grade 22 grades · 1 in reserve 680.4 127% 11,000n/a82n/a500 Digitised
LWFA-E-500-01AC 41 Grade 22 grades · 1 in reserve 635.6 112% 8,380n/a75n/a500 Digitised
LWBE3G500-188PT-04EC 41 Grade 22 grades · 1 in reserve 713.5 138% 14,2143,00089400500 Digitised Curve Datasheet
LWBE3G450-188NT-21EC 39 2,452 rpm4 grades · 2 in reserve 1072.1 257% 12,6474,60096380450 Digitised Curve Datasheet
LWBE3G630-188PT-04EC 35 Grade 1Single grade 1433.9 378% 21,7425,600n/a400630 Digitised Curve Datasheet
LWBE3G630-188PT-01EC 35 10 VHighest grade, no reserve 650.7 117% 19,2472,195n/a400630 Digitised Curve Datasheet
LWBE3G500-188PT-05EC 35 Grade 1Single grade 936.7 212% 13,4724,20088400500 Digitised Curve Datasheet
LWBE3G500-188PT-02EC 35 Grade 1Single grade 869 190% 12,2433,160n/a400500 Digitised Curve Datasheet
LWBE3G400-188PT-07EC 35 Grade 1Highest grade, no reserve 730.2 143% 9,6822,06084400400 Digitised Curve Datasheet
LWBE3G400-188NT-17EC 35 Grade 1Highest grade, no reserve 730.3 143% 9,6822,06084400400 Digitised Curve Datasheet
LWBA4D630-188NT-03AC 35 Grade 1Single grade 620.3 107% 17,9553,32086.9380630 Digitised Curve Datasheet
LWBA4D560-188NT-03AC 35 Grade 1Single grade 651.5 117% 11,3302,50085380560 Digitised Curve Datasheet
LWBA4D560-188NT-01AC 35 Grade 1Single grade 658.2 119% 13,2872,50085380560 Digitised Curve Datasheet
LWEA800TM-169EAC 65.3 Nameplatecurve on request 372.5 24% 37,3704,000n/a380800 Estimated

“Measured” = wind-tunnel test data; “Digitised” = read from the catalogue curve, for pre-selection; “Estimated” = no curve in the library yet — the pressure at your airflow is estimated from the nameplate maxima with a conservative straight-line curve, so ask for the measured curve before finalising. Power, noise and max airflow are nameplate values, not values at your duty point. Final selection is subject to duty-point verification and engineering confirmation.

Know the fan type you need? Enter the category and see its full parameter range.

Only know the application? Pick it below — each duty point is pre-verified against the library.

Not sure what airflow and static pressure to enter? Pick the closest application — every duty point below returns matching models from our measured library.

2,616models
Ø24–1,000impeller size, mm
0–61kairflow, m³/h
849measured P-Q curves
2,316dimensional drawings

Browse by product line

Every category page is a selector for that fan type: filter by airflow, static pressure, voltage, size and motor, then compare in the data table.

Axial FansAxial Fans435 models

High airflow, low–medium pressure: condensers, heat pumps, ventilation

Cross Flow FansCross Flow Fans318 models

Even linear discharge, low noise: indoor AC units, air curtains

Commercial Centrifugal BlowersCommercial Centrifugal Blowers26 models

DD direct drive and LWFA series for kitchens and ventilation units

Gas BlowersGas Blowers56 models

Burner and boiler air supply, premix and forced draft

Explosion-Proof FansExplosion-Proof Fans31 models

Ex-rated axial and centrifugal fans for hazardous areas

Poultry & Livestock FansPoultry & Livestock Fans30 models

Tunnel and minimum ventilation for barns and greenhouses

Motor Cooling FansMotor Cooling Fans30 models

Forced cooling for VFD-driven motors

Rail Transit FansRail Transit Fans11 models

Vehicle and platform ventilation

Exhaust FansExhaust Fans13 models

Wall and roof exhaust, floor dryers

Anti-Corrosion Fans4 models

PP / FRP fans for corrosive and humid air

How selection works here

Three steps from duty point to quotation — no login, no spreadsheet.

1Enter the duty pointAirflow and static pressure at the design condition. Use the application presets if you only know the use case.
2Check the curveEach result shows the speed grade that meets the point, the available pressure and the margin. 10–25% margin is ideal.
3Get files and quoteDownload the dimensional drawing, P-Q curve and datasheet. Add models to the RFQ list and submit once — an engineer replies within 1 business day.

Why buyers specify LONGWELL

Ningbo Longwell Electric Technology — HVACR fans and motors since 1990, exporting to 30+ countries.

The data is measured, not scaled

Six in-house laboratories produce every curve and noise figure on this site. Third-party test reports on request.

Certificates you can verify by number

Management systems and product compliance per product line; scans of every original are on the certifications page.

Since 1990Ningbo Longwell Electric Technology Co., Ltd. — HVACR fans & motors, 36 years
30+ countriesOEM / ODM partner; offices in Russia (2022), Türkiye (2023) and Poland (2024)
2,616 models849 measured P-Q curves, drawings and datasheets online
Samples 1–3 daysproduction batches 15–30 days ex works Ningbo
Reply in 1 business dayengineer-checked quotation with curve and lead time

See the test labs, core technology and all certificate scans →

Send us the duty point and we do the selection

Airflow, static pressure, voltage, control mode and quantity — that is all our engineers need to propose the best-fit model with curve and lead time.

Ask an engineer   Download center
Scroll to Top
RFQ list