Cooling Fans & Blowers

Filter by duty point879 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAD12025LL-10 LWAD12025LL-10DC 120 mm 210.6 150 7.2 52.8 3,500 12 Details
LWAD12025LM-04 LWAD12025LM-04DC 120 mm 142.2 47 12 39.7 2,500 12 Details
LWAD12025LM-09 LWAD12025LM-09DC 120 mm 241.2 196 12 55.7 4,000 12 Details
LWAD12025LX-01 LWAD12025LX-01DC 120 mm 255.6 151 24 52.5 4,500 12 Details
LWAD12025LX-02 LWAD12025LX-02DC 120 mm 227.4 119 24 49.9 4,000 12 Details
LWAD12025LX-03 LWAD12025LX-03DC 120 mm 198.6 91 24 47 3,500 12 Details
LWAD12025LX-07 LWAD12025LX-07DC 120 mm 301.2 249 24 60.5 5,000 12 Details
LWAD12025MD-06 LWAD12025MD-06DC 120 mm 85.2 17 4.8 28.6 1,500 24 Details
LWAD12025MH-03 LWAD12025MH-03DC 120 mm 170.4 67 19.2 43.7 3,000 24 Details
LWAD12025MH-08 LWAD12025MH-08DC 120 mm 271.2 249 19.2 58.2 4,500 24 Details
LWAD12025ML-05 LWAD12025ML-05DC 120 mm 113.4 30 12 34.8 2,000 24 Details
LWAD12025ML-10 LWAD12025ML-10DC 120 mm 210.6 150 12 52.8 3,500 24 Details
LWAD12025MM-04 LWAD12025MM-04DC 120 mm 142.2 47 14.4 39.7 2,500 24 Details
LWAD12025MM-09 LWAD12025MM-09DC 120 mm 241.2 196 14.4 55.7 4,000 24 Details
LWAD12025MX-01 LWAD12025MX-01DC 120 mm 255.6 151 24 52.5 4,500 24 Details
LWAD12025MX-02 LWAD12025MX-02DC 120 mm 227.4 119 24 49.9 4,000 24 Details
LWAD12025MX-03 LWAD12025MX-03DC 120 mm 198.6 91 24 47 3,500 24 Details
LWAD12025MX-07 LWAD12025MX-07DC 120 mm 301.2 249 24 60.5 5,000 24 Details
LWAD12038HD-08 LWAD12038HD-08DC 120 mm 238.2 127 9.6 55.2 4,000 48 Details
LWAD12038HD-16 LWAD12038HD-16DC 120 mm 170.4 78 7.2 44.5 2,500 48 Details
LWAD12038HH-02 LWAD12038HH-02DC 120 mm 331.8 181 24 55.7 4,200 48 Details
LWAD12038HH-05 LWAD12038HH-05DC 120 mm 327.6 240 28.8 62.1 5,500 48 Details
LWAD12038HH-13 LWAD12038HH-13DC 120 mm 272.4 199 16.8 54.7 4,000 48 Details
LWAD12038HL-07 LWAD12038HL-07DC 120 mm 268.2 161 14.4 57.8 4,500 48 Details
LWAD12038HL-15 LWAD12038HL-15DC 120 mm 204.6 112 9.6 48.5 3,000 48 Details
LWAD12038HM-03 LWAD12038HM-03DC 120 mm 284.4 133 16.8 52.4 3,600 48 Details
LWAD12038HM-06 LWAD12038HM-06DC 120 mm 297.6 199 24 60 5,000 48 Details
LWAD12038HM-14 LWAD12038HM-14DC 120 mm 238.2 152 12 51.8 3,500 48 Details
LWAD12038HX-01 LWAD12038HX-01DC 120 mm 361.2 210 57.6 58.5 4,600 48 Details
LWAD12038HX-04 LWAD12038HX-04DC 120 mm 357.6 286 38.4 64 6,000 48 Details
LWAD12038HX-09 LWAD12038HX-09DC 120 mm 408.6 448 57.6 63.5 6,000 48 Details
LWAD12038HX-10 LWAD12038HX-10DC 120 mm 374.4 376 57.6 61.6 5,500 48 Details
LWAD12038HX-11 LWAD12038HX-11DC 120 mm 340.8 311 57.6 59.5 5,000 48 Details
LWAD12038HX-12 LWAD12038HX-12DC 120 mm 306.6 252 57.6 57.3 4,500 48 Details
LWAD12038LD-08 LWAD12038LD-08DC 120 mm 238.2 127 9.6 55.2 4,000 12 Details
LWAD12038LD-16 LWAD12038LD-16DC 120 mm 170.4 78 6 44.5 2,500 12 Details
LWAD12038LH-02 LWAD12038LH-02DC 120 mm 331.8 181 18 55.7 4,200 12 Details
LWAD12038LH-05 LWAD12038LH-05DC 120 mm 327.6 240 18 62.1 5,500 12 Details
LWAD12038LH-13 LWAD12038LH-13DC 120 mm 272.4 199 18 54.7 4,000 12 Details
LWAD12038LL-07 LWAD12038LL-07DC 120 mm 268.2 161 12 57.8 4,500 12 Details

Cooling Fans & Blowers — selection guide

The Cooling Fans & Blowers category currently lists 879 models, frame sizes 24–254 mm, maximum airflow 2–4,800 m³/h, static pressure up to 2,650 Pa, on DC / AC / EC motors, across 54 series. 157 models carry a measured P-Q curve for duty-point selection and 864 a dimensional drawing. Common voltages: 12 V, 24 V, 48 V, 5 V, 100-240 V.

Compact cooling fans and blowers keep electronics, power supplies, cabinets, chargers and battery packs within temperature limits. Frame sizes run from 25 to 200 mm for axial fans and Ø40–120 mm for DC centrifugal blowers, on 5 / 12 / 24 / 48 V DC, EC or AC platforms, with ball bearings for long life and options for PWM control, tacho signal and IP protection.

How to select a Cooling Fans & Blower

  1. Calculate the airflow from the heat load: Q (m³/h) ≈ 3 × heat (W) / ΔT (K) for air, then add resistance for filters and grilles.
  2. Pick the largest frame size that fits: a larger, slower fan moves the same air at much lower noise and higher service life.
  3. Use DC blowers where the air has to be pushed through a narrow channel or heatsink with high resistance; axial fans for open cabinets and panels.
  4. Specify the control interface — PWM, tacho, 0–10 V or alarm output — at the outset; it defines the motor electronics.
  5. Check service life at the real ambient temperature: L10 life halves for roughly every 10 K above the rated temperature.

Typical applications

  • Power supplies and inverters
  • Telecom and server cabinets
  • EV chargers and battery packs
  • Medical and laboratory devices
  • Displays, projectors and appliances

Why specify LONGWELL cooling fans & blowers

Every model here is a current production item with structured data — not a catalogue scan. Curves are tested on our own wind-tunnel rigs per AMCA 210 / ISO 5801 methods, drawings and datasheets download directly, CAD is released on request, and a quotation with the duty-point check comes back within one business day. Samples ship in 1–3 days and production batches in 15–30 days from the factory in Ningbo, with ISO 9001 / 14001 / 45001 management systems and ETL, CE and RoHS documentation per product line.

FAQs — Cooling Fans & Blowers

How do I calculate the cooling fan airflow I need?

A practical estimate for air cooling is Q (m³/h) ≈ 3 × P (W) / ΔT (K), where P is the heat to remove and ΔT the allowed air temperature rise. Then add the resistance of filters, grilles and heatsinks and choose a fan whose curve covers that point.

Which frame sizes are available?

Axial cooling fans from 25 × 25 mm up to 200 mm, DC centrifugal blowers Ø40–120 mm and EC cooling fans Ø60–254 mm. Use the size buckets in this category to browse by frame size.

Are PWM control and tacho output available?

Yes. Most DC models can be supplied with PWM speed control, tacho (FG) signal or alarm (RD) output; EC models add 0–10 V control and fault feedback. The option is part of the model code — ask if the variant you need is not listed.

What is the service life of your cooling fans?

Ball-bearing models are rated 30,000–40,000 hours L10 at 40 °C depending on the series; the value is shown in the technical data of each model. Life shortens with temperature and dust load.

Do you support UL / CE requirements for equipment approval?

Fans are built with UL94 V-0 materials and CE / RoHS documentation; ETL-listed families are marked on the certifications page. Declarations for a specific model are issued on request.