Cooling Fans & Blowers

Filter by duty point879 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAD12025LL-10 LWAD12025LL-10DC 120 mm 210.6 150 7.2 52.8 3,500 12 Details
LWAD12025LM-04 LWAD12025LM-04DC 120 mm 142.2 47 12 39.7 2,500 12 Details
LWAD12025LM-09 LWAD12025LM-09DC 120 mm 241.2 196 12 55.7 4,000 12 Details
LWAD12025LX-01 LWAD12025LX-01DC 120 mm 255.6 151 24 52.5 4,500 12 Details
LWAD12025LX-02 LWAD12025LX-02DC 120 mm 227.4 119 24 49.9 4,000 12 Details
LWAD12025LX-03 LWAD12025LX-03DC 120 mm 198.6 91 24 47 3,500 12 Details
LWAD12025LX-07 LWAD12025LX-07DC 120 mm 301.2 249 24 60.5 5,000 12 Details
LWAD12025MD-06 LWAD12025MD-06DC 120 mm 85.2 17 4.8 28.6 1,500 24 Details
LWAD12025MH-03 LWAD12025MH-03DC 120 mm 170.4 67 19.2 43.7 3,000 24 Details
LWAD12025MH-08 LWAD12025MH-08DC 120 mm 271.2 249 19.2 58.2 4,500 24 Details
LWAD12025ML-05 LWAD12025ML-05DC 120 mm 113.4 30 12 34.8 2,000 24 Details
LWAD12025ML-10 LWAD12025ML-10DC 120 mm 210.6 150 12 52.8 3,500 24 Details
LWAD12025MM-04 LWAD12025MM-04DC 120 mm 142.2 47 14.4 39.7 2,500 24 Details
LWAD12025MM-09 LWAD12025MM-09DC 120 mm 241.2 196 14.4 55.7 4,000 24 Details
LWAD12025MX-01 LWAD12025MX-01DC 120 mm 255.6 151 24 52.5 4,500 24 Details
LWAD12025MX-02 LWAD12025MX-02DC 120 mm 227.4 119 24 49.9 4,000 24 Details
LWAD12025MX-03 LWAD12025MX-03DC 120 mm 198.6 91 24 47 3,500 24 Details
LWAD12025MX-07 LWAD12025MX-07DC 120 mm 301.2 249 24 60.5 5,000 24 Details
LWAD12038HD-08 LWAD12038HD-08DC 120 mm 238.2 127 9.6 55.2 4,000 48 Details
LWAD12038HD-16 LWAD12038HD-16DC 120 mm 170.4 78 7.2 44.5 2,500 48 Details
LWAD12038HH-02 LWAD12038HH-02DC 120 mm 331.8 181 24 55.7 4,200 48 Details
LWAD12038HH-05 LWAD12038HH-05DC 120 mm 327.6 240 28.8 62.1 5,500 48 Details
LWAD12038HH-13 LWAD12038HH-13DC 120 mm 272.4 199 16.8 54.7 4,000 48 Details
LWAD12038HL-07 LWAD12038HL-07DC 120 mm 268.2 161 14.4 57.8 4,500 48 Details
LWAD12038HL-15 LWAD12038HL-15DC 120 mm 204.6 112 9.6 48.5 3,000 48 Details
LWAD12038HM-03 LWAD12038HM-03DC 120 mm 284.4 133 16.8 52.4 3,600 48 Details
LWAD12038HM-06 LWAD12038HM-06DC 120 mm 297.6 199 24 60 5,000 48 Details
LWAD12038HM-14 LWAD12038HM-14DC 120 mm 238.2 152 12 51.8 3,500 48 Details
LWAD12038HX-01 LWAD12038HX-01DC 120 mm 361.2 210 57.6 58.5 4,600 48 Details
LWAD12038HX-04 LWAD12038HX-04DC 120 mm 357.6 286 38.4 64 6,000 48 Details
LWAD12038HX-09 LWAD12038HX-09DC 120 mm 408.6 448 57.6 63.5 6,000 48 Details
LWAD12038HX-10 LWAD12038HX-10DC 120 mm 374.4 376 57.6 61.6 5,500 48 Details
LWAD12038HX-11 LWAD12038HX-11DC 120 mm 340.8 311 57.6 59.5 5,000 48 Details
LWAD12038HX-12 LWAD12038HX-12DC 120 mm 306.6 252 57.6 57.3 4,500 48 Details
LWAD12038LD-08 LWAD12038LD-08DC 120 mm 238.2 127 9.6 55.2 4,000 12 Details
LWAD12038LD-16 LWAD12038LD-16DC 120 mm 170.4 78 6 44.5 2,500 12 Details
LWAD12038LH-02 LWAD12038LH-02DC 120 mm 331.8 181 18 55.7 4,200 12 Details
LWAD12038LH-05 LWAD12038LH-05DC 120 mm 327.6 240 18 62.1 5,500 12 Details
LWAD12038LH-13 LWAD12038LH-13DC 120 mm 272.4 199 18 54.7 4,000 12 Details
LWAD12038LL-07 LWAD12038LL-07DC 120 mm 268.2 161 12 57.8 4,500 12 Details

Cooling Fans & Blowers — selection guide

Cooling Fans & Blowers: 879 models, frame sizes 24–254 mm, maximum airflow 2–4,800 m³/h, static pressure to 2,650 Pa, DC, AC and EC motors, across 54 series. 157 of them carry a measured P-Q curve and 864 a dimensional drawing.

This is the compact end of the catalogue: 879 models for cooling electronics, cabinets and equipment. DC axial fans (LWAD) run from 25 × 25 mm to 200 mm frame with thicknesses from 10 to 60 mm, DC centrifugal blowers (LWFD) from Ø40 to Ø120 mm for pushing air through heatsinks and ducts, EC cooling fans (LWAE) from 60 to 254 mm on a 100–240 V universal AC input, and AC air blowers (LWB / LWT) for blow-off and air-knife duties up to 2,650 Pa.

Frames are UL94 V-0 plastic, supply voltages 5 / 12 / 24 / 48 V DC, and the model code carries frame, thickness and speed grade — LWAD8025HL is an 80 × 25 mm fan in the H-speed L-variant. Ball-bearing versions are the standard for continuous duty.

How to select from this range

  1. Estimate airflow from the heat load: Q (m³/h) ≈ 3 × P (W) / ΔT (K), then add the resistance of filters, grilles and heatsinks.
  2. Take the largest frame that fits — a bigger fan at lower speed gives the same airflow at far lower noise and longer life.
  3. Use a DC blower (LWFD) where air must be forced through a narrow channel or dense heatsink; an axial fan where the enclosure is open.
  4. Specify the control interface at the outset: PWM, tacho (FG), alarm (RD) or 0–10 V; it is part of the model code.
  5. Check life at the real ambient: ball-bearing L10 ratings are given at 40 °C and halve for roughly every 10 K above.

Where these fans are used

  • Power supplies, UPS and inverters
  • Telecom and server cabinets
  • EV chargers and battery packs
  • Medical and laboratory devices
  • Displays, projectors and appliances

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cooling Fans & Blowers

How do I decode a cooling fan model such as LWAD8025HL?

LWAD = DC axial cooling fan (LWFD = DC blower, LWAE = EC), 80 = frame in mm, 25 = thickness in mm, H = speed grade (H / M / L), L = variant. Within one frame the speed grades trade airflow against noise; the technical data lists each.

Which frame sizes are in stock as standard?

40, 50, 60, 70, 80, 92 and 120 mm frames carry the most variants (up to 15 per series), which is where samples ship fastest. 25, 30, 172 and 200 mm are also catalogued.

Can you supply PWM control and tacho output?

Yes. Most DC frames are available with PWM speed input, FG tacho signal and RD alarm output; EC models add 0–10 V control. Tell us the required signal when you request the sample.

Do the cooling fans have UL / CE documentation?

Frames are UL94 V-0, CE / RoHS declarations are available per model, and the DC centrifugal blower line is ETL listed (Intertek control no. 5022563).

Related selections

Scroll to Top
RFQ list