Fan Coil Units
Metal fan coil units (FCU) for chilled / hot water terminal systems: horizontal and vertical, exposed and concealed, plus cassette types. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.
Browse by size
Browse by series
| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWFC-1020KMAC | — | 1,020 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-1020LAAC | — | 1,020 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-1020LMAC | — | 1,020 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-1020WAAC | — | 1,020 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-1020WMAC | — | 1,020 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-1360KMAC | — | 1,360 | see curve | 134 | — | — | 220 | Details |
![]() |
LWFC-1360LAAC | — | 1,360 | see curve | 134 | — | — | 220 | Details |
![]() |
LWFC-1360LMAC | — | 1,360 | see curve | 134 | — | — | 220 | Details |
![]() |
LWFC-1360WAAC | — | 1,360 | see curve | 134 | — | — | 220 | Details |
![]() |
LWFC-1360WMAC | — | 1,360 | see curve | 134 | — | — | 220 | Details |
![]() |
LWFC-1700KMAC | — | 1,700 | see curve | 152 | — | — | 220 | Details |
![]() |
LWFC-1700LAAC | — | 1,700 | see curve | 152 | — | — | 220 | Details |
![]() |
LWFC-1700LMAC | — | 1,700 | see curve | 152 | — | — | 220 | Details |
![]() |
LWFC-1700WAAC | — | 1,700 | see curve | 152 | — | — | 220 | Details |
![]() |
LWFC-1700WMAC | — | 1,700 | see curve | 152 | — | — | 220 | Details |
![]() |
LWFC-2040KMAC | — | 2,040 | see curve | 189 | — | — | 220 | Details |
![]() |
LWFC-2040LAAC | — | 2,040 | see curve | 189 | — | — | 220 | Details |
![]() |
LWFC-2040LMAC | — | 2,040 | see curve | 189 | — | — | 220 | Details |
![]() |
LWFC-2040WAAC | — | 2,040 | see curve | 189 | — | — | 220 | Details |
![]() |
LWFC-2040WMAC | — | 2,040 | see curve | 189 | — | — | 220 | Details |
![]() |
LWFC-2380KMAC | — | 2,380 | see curve | 228 | — | — | 220 | Details |
![]() |
LWFC-2380LAAC | — | 2,380 | see curve | 228 | — | — | 220 | Details |
![]() |
LWFC-2380LMAC | — | 2,380 | see curve | 228 | — | — | 220 | Details |
![]() |
LWFC-2380WAAC | — | 2,380 | see curve | 228 | — | — | 220 | Details |
![]() |
LWFC-2380WMAC | — | 2,380 | see curve | 228 | — | — | 220 | Details |
![]() |
LWFC-340KMAC | — | 340 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-340LAAC | — | 340 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-340LMAC | — | 340 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-340WAAC | — | 340 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-340WMAC | — | 340 | see curve | — | — | — | 220 | Details |
![]() |
LWFC-510KMAC | — | 510 | see curve | 52 | — | — | 220 | Details |
![]() |
LWFC-510LAAC | — | 510 | see curve | 52 | — | — | 220 | Details |
![]() |
LWFC-510LMAC | — | 510 | see curve | 52 | — | — | 220 | Details |
![]() |
LWFC-510WAAC | — | 510 | see curve | 52 | — | — | 220 | Details |
![]() |
LWFC-510WMAC | — | 510 | see curve | 52 | — | — | 220 | Details |
![]() |
LWFC-680LAAC | — | 680 | see curve | 62 | — | — | 220 | Details |
![]() |
LWFC-680LMAC | — | 680 | see curve | 62 | — | — | 220 | Details |
![]() |
LWFC-680WAAC | — | 680 | see curve | 62 | — | — | 220 | Details |
![]() |
LWFC-680WMAC | — | 680 | see curve | 62 | — | — | 220 | Details |
![]() |
LWFC-850KMAC | — | 850 | see curve | 76 | — | — | 220 | Details |
Fan Coil Units — selection guide
Fan Coil Units: 44 models, maximum airflow 340–2,380 m³/h, AC motors, across 9 series.
LONGWELL fan coil units are chilled-water and hot-water terminal units in nine airflow classes from 340 to 2,380 m³/h (LWFC-340 to LWFC-2380), 52–228 W input on 220 V single-phase. The suffix gives the format: WA horizontal concealed, WM horizontal exposed, LA vertical concealed, LM vertical exposed, KM four-way cassette. All nine classes are available in the horizontal and vertical formats; eight in the cassette format.
The units share the same coil and three-speed motor platform, so a project can mix concealed, exposed and cassette units of the same capacity class.
How to select from this range
- Size by room cooling / heating load at the design water temperatures, then check that medium-speed airflow gives acceptable distribution and noise.
- Concealed units (WA / LA) need external static pressure for the duct and grille — check the ESP rating for the run length.
- Cassette units (KM) suit open-plan spaces with a suspended ceiling; exposed units (WM / LM) where there is no ceiling void.
- Specify the control valve and thermostat interface with the order.
Where these fans are used
- Hotel rooms and offices
- Hospitals and schools
- Residential chilled-water systems
Curves marked “measured” come from our own test rigs per AMCA 210 / ISO 5801 methods; digitised catalogue curves are flagged as such in the selector — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — Fan Coil Units
What do the LWFC suffixes WA, WM, LA, LM and KM mean?
W = horizontal, L = vertical, K = cassette; A = concealed, M = exposed. LWFC-850WA is the 850 m³/h horizontal concealed unit, LWFC-850KM the 850 m³/h cassette.
Which capacity classes are available?
Nine airflow classes: 340, 510, 680, 850, 1,020, 1,360, 1,700, 2,040 and 2,380 m³/h. Capacity tables at your water temperatures are provided by our engineers.
Are EC-motor fan coil units available?
EC versions with 0–10 V control are offered on request for projects that need lower consumption and finer room control.