- Frame size80 mm3.1 in
- Max airflow63.6 m³/h37 CFM
- Max static pressure45 Pa0.18 in. wg
- Voltage12 V
- Speed3,250 rpm
- Input power2.4 W
- Noise34 dB(A)
LWAD8025LX-28 DC Electronics Cooling Fan 80 mm
80 mm | DC | Max airflow 63.6 m³/h | Max static pressure 45 Pa | 34 dB(A)
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Dimensional drawing LWAD8025LX-28

Files for LWAD8025LX-28: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWAD8025LX-28
LWAD8025LX-28 is a LONGWELL DC Electronics Cooling Fan, frame 80 mm, rated 12 V DC, maximum airflow 63.6 m³/h, maximum static pressure 45 Pa, noise 34 dB(A), input power 2.4 W.
Technical data
| Model | LWAD8025LX-28 |
|---|---|
| Series | LWAD8025 |
| Motor type | DC |
| Rated voltage | 12 V |
| Current | 0.2 A |
| Input power | 2.4 W |
| Speed | 3,250 rpm |
| Max. airflow | 63.6 m³/h |
| Max. static pressure | 45 Pa |
| Noise | 34 dB(A) |
| Frame size | 80 mm |
Nameplate values; final selection is confirmed at the duty point and by project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWAD8025LX-28
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Alternatives with the same frame size (80 mm · DC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWAD8025LX-28 this model | 63.6 m³/h | 45 Pa | 3,250 rpm | 2.4 W | 34 dB(A) | 12 V | |
| LWAD8025XL-01 | 49.3 m³/h | 27.6 Pa | 2,500 rpm | 1.25 W | 26 dB(A) | 5 V | View |
| LWAD8025ML-27 | 49.3 m³/h | 27.6 Pa | 2,500 rpm | 1.44 W | 26 dB(A) | 24 V | View |
| LWAD8025XM-02 | 53.4 m³/h | 32.2 Pa | 2,700 rpm | 1.65 W | 28 dB(A) | 5 V | View |
| LWAD8025MM-28 | 53.4 m³/h | 32.2 Pa | 2,700 rpm | 1.44 W | 28 dB(A) | 24 V | View |
| LWAD8025XH-03 | 60 m³/h | 39.6 Pa | 3,000 rpm | 2.15 W | 31 dB(A) | 5 V | View |
| LWAD8025MH-29 | 60 m³/h | 39.6 Pa | 3,000 rpm | 1.68 W | 31 dB(A) | 24 V | View |
| LWAD8025MX-30 | 63.6 m³/h | 45 Pa | 3,250 rpm | 2.16 W | 34 dB(A) | 24 V | View |
| LWAD8025MX-32 | 70 m³/h | 47.3 Pa | 3,300 rpm | 1.44 W | 37.5 dB(A) | 24 V | View |
| LWAD8025MX-31 | 71.4 m³/h | 54 Pa | 3,600 rpm | 3.36 W | 38 dB(A) | 24 V | View |
| LWAD8025MX-33 | 73.7 m³/h | 51.3 Pa | 3,500 rpm | 1.8 W | 40.5 dB(A) | 24 V | View |
| LWAD8038ML-17 | 78.6 m³/h | 66.3 Pa | 3,600 rpm | 4.32 W | 48.5 dB(A) | 24 V | View |
| LWAD8038LL-17 | 78.6 m³/h | 66.3 Pa | 3,600 rpm | 4.32 W | 48.5 dB(A) | 12 V | View |
| LWAD8038MH-18 | 113.6 m³/h | 138.3 Pa | 5,200 rpm | 6.48 W | 56.5 dB(A) | 24 V | View |
| LWAD8038LH-18 | 113.6 m³/h | 138.3 Pa | 5,200 rpm | 6.36 W | 56.5 dB(A) | 12 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWAD8025 seriesSame impeller, different speed grade or wiring
LWAD8025LX-0180 mm · 155.4 m³/h · 153 Pa · DCsame series
LWAD8025LX-0280 mm · 143.4 m³/h · 130 Pa · DCsame series
LWAD8025LX-0380 mm · 131.4 m³/h · 109 Pa · DCsame series
LWAD8025LX-0480 mm · 120 m³/h · 90 Pa · DCsame series
LWAD8025LX-0580 mm · 108 m³/h · 73 Pa · DCsame series
LWAD8025LH-0680 mm · 96 m³/h · 58 Pa · DCsame seriesAdjacent sizesOne size up when airflow is short, one size down when it is too much
LWFD7515LL-0475 mm · 7.8 m³/h · 75 Pa · DCadjacent size
LWFD7515MH-0275 mm · 10.8 m³/h · 148 Pa · DCadjacent size
LWFD7515MX-0175 mm · 11.4 m³/h · 165 Pa · DCadjacent size
LWFD7515LD-0575 mm · 6 m³/h · 48 Pa · DCadjacent size
LWFD7515LH-0275 mm · 10.8 m³/h · 148 Pa · DCadjacent size
LWFD7515LX-0175 mm · 11.4 m³/h · 165 Pa · DCadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWAD8025MX-3080 mm · 63.6 m³/h · 45 Pa · DCsimilar duty
LWAD9215LH-0392 mm · 63.6 m³/h · 31.8 Pa · DCsimilar duty
LWAD9215MH-0392 mm · 63.6 m³/h · 31.8 Pa · DCsimilar duty
LWAD8015LX-1180 mm · 63.9 m³/h · 38.7 Pa · DCsimilar duty
LWAD8015MX-1080 mm · 63.9 m³/h · 38.7 Pa · DCsimilar duty
LWAD8020LH-0280 mm · 64.2 m³/h · 49 Pa · DCsimilar dutySee all Cooling Fans & Blowers · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for cooling fans & blowers — on our main site.
Solutions
- Battery energy storageBESS containers and cabinets
- Data center coolingCRAH, FanGrid, server rooms
- Home appliance coolingHoods, ovens, dryers, air conditioners