• Frame size92 mm3.6 in
  • Max airflow63.6 m³/h37 CFM
  • Max static pressure31.8 Pa0.13 in. wg
  • Voltage24 V
  • Speed2,850 rpm
  • Input power3.12 W
  • Noise34 dB(A)

LWAD9215MH-03 DC Electronics Cooling Fan 92 mm

92 mm | DC | Max airflow 63.6 m³/h | Max static pressure 31.8 Pa | 34 dB(A)

  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWAD9215MH-032 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Dimensional drawing LWAD9215MH-03

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWAD9215MH-03 Dimensional drawing

Files for LWAD9215MH-03: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWAD9215MH-03

LWAD9215MH-03 is a LONGWELL DC Electronics Cooling Fan, frame 92 mm, rated 24 V DC, maximum airflow 63.6 m³/h, maximum static pressure 31.8 Pa, noise 34 dB(A), input power 3.12 W.

Technical data

Model LWAD9215MH-03
Series LWAD9215
Motor type DC
Rated voltage 24 V
Current 0.13 A
Input power 3.12 W
Speed 2,850 rpm
Max. airflow 63.6 m³/h
Max. static pressure 31.8 Pa
Noise 34 dB(A)
Frame size 92 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWAD9215MH-03

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same frame size (92 mm · DC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWAD9215MH-03 this model 63.6 m³/h31.8 Pa 2,850 rpm3.12 W34 dB(A)24 V
LWAD9225XL-01 63 m³/h24.8 Pa 2,100 rpm0.8 W25 dB(A)5 V View
LWAD9225ML-20 63 m³/h24.8 Pa 2,100 rpm1.44 W25 dB(A)24 V View
LWAD9225XM-02 74.4 m³/h31.9 Pa 2,450 rpm1.3 W30 dB(A)5 V View
LWAD9225MM-21 74.4 m³/h31.9 Pa 2,450 rpm1.92 W30 dB(A)24 V View
LWAD9225LM-23 74.4 m³/h31.9 Pa 2,450 rpm1.32 W30 dB(A)12 V View
LWAD9225MH-22 87 m³/h44.1 Pa 2,850 rpm2.4 W34 dB(A)24 V View
LWAD9225MX-23 98.4 m³/h55.1 Pa 3,200 rpm3.12 W38 dB(A)24 V View
LWAD9225LX-25 98.4 m³/h55.1 Pa 3,200 rpm3 W38 dB(A)12 V View
LWAD9225MX-24 115.2 m³/h75.2 Pa 3,850 rpm5.28 W45 dB(A)24 V View
LWAD9225LX-26 115.2 m³/h75.2 Pa 3,850 rpm4.8 W45 dB(A)12 V View
LWAD9238MX-17 249.8 m³/h387.4 Pa 7,000 rpm24 W65 dB(A)24 V View
LWAD9238LX-18 249.8 m³/h387.4 Pa 7,000 rpm24 W65 dB(A)12 V View
LWAD9238MX-18 285.4 m³/h505 Pa 8,000 rpm48 W69 dB(A)24 V View
LWAD9238LX-19 285.4 m³/h505 Pa 8,000 rpm48 W69 dB(A)12 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for cooling fans & blowers — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote