LWBE3G560-188NT-14 product photo
LWBE3G560-188NT-14 product photo
  • ImpellerØ560 mm22.0 in
  • Max airflow19,760 m³/h11,624 CFM
  • Max static pressure1,545 Pa6.20 in. wg
  • Voltage380 V
  • Speed1,850 rpm
  • Input power4,700 W6.30 hp
  • Noise91 dB(A)

LWBE3G560-188NT-14 EC Backward Curved Centrifugal Fan Ø560 mm

Ø560 mm | EC | Max airflow 19,760 m³/h | Max static pressure 1,545 Pa | 91 dB(A)

  • Factory direct
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 18-month warranty
  • CE · RoHS · ETL on request
View RFQ →
Engineering files (on request)

CAD files exist for this model and can be released for assembly checks in SolidWorks / CATIA / Creo / Inventor.

CAD models contain the blade geometry and are not downloadable. Tell us the project; an engineer sends the file after a short check, normally within 1 business day.

Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWBE3G560-188NT-14 Dimensional drawing
Performance curve (P-Q)Static pressure vs. airflow. Curve numbers correspond to supply voltage / speed grades.
LWBE3G560-188NT-14 Performance curve (P-Q)
Wiring diagramLead colours and terminal assignment; TK = motor thermal contact.
LWBE3G560-188NT-14 Wiring diagram

Downloads for LWBE3G560-188NT-14

DOCXDatasheet · 659 KBPDFDatasheet · 710 KB

Need a non-standard size or another format? Ask an engineer or search the download center.

LWBE3G560-188NT-14 is a LONGWELL EC Backward Curved Centrifugal Fan from the Backward Curved Centrifugal Fans range, impeller Ø560 mm, rated 380 V EC, maximum airflow 19,760 m³/h, maximum static pressure 1,545 Pa, noise 91 dB(A), input power 4,700 W. The EC motor integrates the drive electronics: stepless speed control by 0–10 V or PWM signal, speed feedback and high efficiency at part load.

Technical data

Model LWBE3G560-188NT-14
Series LWBE3G560
Motor type EC
Phase 3-phase
Rated voltage 380 V
Frequency 50 Hz
Current 7.9 A
Input power 4,700 W
Speed 1,850 rpm
Max. airflow 19,760 m³/h
Max. airflow (CFM) 11,624 CFM
Max. static pressure 1,545 Pa
Noise 91 dB(A)
Ambient temperature -25 ~ 60 °C
Storage temperature -40 ~ 80℃
Humidity 30 ~ 95% RH
Altitude < 1000m
Impeller diameter Ø560 mm
Rotor diameter 188
Impeller material Aluminum Alloy (Impeller)
Protection class IP54
Insulation class F
Bearing Maintenance-free deep groove ball bearings
Duty S1
Balance grade G6.3
Vibration standard JB/T 8689
Service life 40,000Hours(L10). At 40℃ room, humidity 15%~65%RH
Speed control Control input 0~10VDC / PWM / RS485
Control signal Control signal VSP voltage range1±0.1VDC~9.5±0.2VDC(During normal operation, when the VSP voltage is below 1.0±0.1VDC, the motor switches from operating mode to standby mode)
PWM input PWM signal: frequency 1K–10KHz, amplitude 10–12V,duty cycle 30%–70% .
Speed feedback Tach output:12 Pulse/R; FG internal open circuit output, external pull-up resistor 10KΩ, pull-up voltage +10V
Auxiliary output Output 10VDC, Max Current 10 mA
Communication LWRS485-01
Protection functions Over-temperature protection, Over-current protection, Locked-rotor protection’
Soft start Delay time <30 seconds to full speed
Rotation Clockwise,seen on rotor

Typical applications

  • Air handling units (AHU) and rooftop units (RTU)
  • Data-center CRAH / CRAC units and fan walls
  • Dust extraction and process ventilation
  • Fan filter units and air purifiers

Series LWBE3G560: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.

Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.

Alternatives with the same impeller (Ø560 mm · EC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWBE3G560-188NT-14 this model 19,760 m³/h1,545 Pa 1,850 rpm4,700 W91 dB(A)380 V
LWBE3G560-188PT-03 14,879 m³/h1,013 Pa 1,500 rpm2,420 W400 V View
LWBE3G560-188NT-10 14,879 m³/h1,013 Pa 1,500 rpm2,420 W85 dB(A)400 V View
LWBE3G560-188PT-01 16,039 m³/h1,166 Pa 1,610 rpm3,300 W400 V View
LWBE3G560-188NT-01 16,039 m³/h1,166 Pa 1,610 rpm3,300 W63 dB(A)400 V View
LWBE3G560-188PT-02 16,480 m³/h886 Pa 1,520 rpm2,770 W81 dB(A)400 V View
LWBE3G560-188NT-09 16,480 m³/h886 Pa 1,520 rpm2,770 W81 dB(A)400 V View
LWBE3G560-188PT-08 19,760 m³/h1,545 Pa 1,850 rpm4,700 W91 dB(A)400 V View
LWBE3G560-218PT-06 23,896 m³/h1,442 Pa 1,800 rpm5,600 W92 dB(A)400 V View
LWBE3G560-218NT-13 23,896 m³/h1,442 Pa 1,800 rpm5,600 W85 dB(A)400 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
RFQ list