Representative image of the series — dimensions and configuration of this model are given in the drawing and data table below.
- ImpellerØ30 mm1.2 in
- Max airflow238 m³/h140 CFM
- Max static pressure16 Pa0.06 in. wg
- Voltage230 V
- Speed2,200 rpm
- Input power16 W
- Noise32 dB(A)
LWCA-30920SN-06 AC Cross Flow Fan Ø30 mm
Ø30 mm | AC | Max airflow 238 m³/h | Max static pressure 16 Pa | 32 dB(A)
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Dimensional drawing LWCA-30920SN-06

Files for LWCA-30920SN-06: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWCA-30920SN-06
LWCA-30920SN-06 is a LONGWELL AC Cross Flow Fan from the AC Cross Flow Fans range, impeller Ø30 mm, rated 230 V AC, maximum airflow 238 m³/h, maximum static pressure 16 Pa, noise 32 dB(A), input power 16 W. The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.
Technical data
| Model | LWCA-30920SN-06 |
|---|---|
| Series | LWCA30920 |
| Motor type | AC |
| Phase | 1-phase |
| Inlet | Triple |
| Rated voltage | 230 V |
| Frequency | 50 Hz |
| Input power | 16 W |
| Speed | 2,200 rpm |
| Max. airflow | 238 m³/h |
| Max. static pressure | 16 Pa |
| Noise | 32 dB(A) |
| Ambient temperature | -25 ~ 60 °C |
| Impeller diameter | Ø30 mm |
| Outlet length | 920mm |
| Impeller material | Aluminum alloy |
| Insulation class | B/F/H |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
Typical applications
- Indoor air-conditioning units
- Air curtains and door air barriers
- Elevator and cabinet ventilation
- Linear air supply in appliances
Series LWCA30920: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWCA-30920SN-06
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Alternatives with the same impeller (Ø30 mm · AC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWCA-30920SN-06 this model | 238 m³/h | 16 Pa | 2,200 rpm | 16 W | 32 dB(A) | 230 V | |
| LWCA-30250SN-07 | 59 m³/h | 11 Pa | 2,400 rpm | 10 W | 26 dB(A) | 230 V | View |
| LWCA-30290SN-07 | 71 m³/h | 12 Pa | 2,400 rpm | 11 W | 27 dB(A) | 230 V | View |
| LWCA-30290UN-06 | 71 m³/h | 12 Pa | 2,400 rpm | 12 W | 27 dB(A) | 115 V | View |
| LWCA-30350SN-07 | 84 m³/h | 13 Pa | 2,400 rpm | 11 W | 27 dB(A) | 230 V | View |
| LWCA-30350UN-06 | 84 m³/h | 13 Pa | 2,400 rpm | 13 W | 27 dB(A) | 115 V | View |
| LWCA-30420SN-07 | 100 m³/h | 14 Pa | 2,400 rpm | 11 W | 28 dB(A) | 230 V | View |
| LWCA-30420UN-06 | 100 m³/h | 14 Pa | 2,400 rpm | 13 W | 28 dB(A) | 115 V | View |
| LWCA-30530SN-06 | 137 m³/h | 13 Pa | 2,200 rpm | 13 W | 29 dB(A) | 230 V | View |
| LWCA-30610SN-06 | 158 m³/h | 13 Pa | 2,200 rpm | 13 W | 29 dB(A) | 230 V | View |
| LWCA-30650SN-06 | 168 m³/h | 14 Pa | 2,200 rpm | 14 W | 29 dB(A) | 230 V | View |
| LWCA-30718SN-06 | 185 m³/h | 14 Pa | 2,200 rpm | 15 W | 30 dB(A) | 230 V | View |
| LWCA-30800SN-06 | 207 m³/h | 15 Pa | 2,200 rpm | 15 W | 31 dB(A) | 230 V | View |
| LWCA-30854SN-06 | 221 m³/h | 16 Pa | 2,200 rpm | 15 W | 31 dB(A) | 230 V | View |
| LWCA-30986SN-06 | 255 m³/h | 17 Pa | 2,200 rpm | 16 W | 33 dB(A) | 230 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWCD-40420MN-07Ø40 mm · 146 m³/h · 25 Pa · DCadjacent size
LWCD-40610MN-06Ø40 mm · 203 m³/h · 26 Pa · DCadjacent size
LWCD-40530MN-06Ø40 mm · 176 m³/h · 25 Pa · DCadjacent size
LWCD-40700MN-06Ø40 mm · 232 m³/h · 26 Pa · DCadjacent size
LWCD-40420LN-06Ø40 mm · 146 m³/h · 25 Pa · DCadjacent size
LWCD-40350MN-07Ø40 mm · 121 m³/h · 24 Pa · DCadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWCD-30920MN-06Ø30 mm · 238 m³/h · 20 Pa · DCsimilar duty
LWAD12038LD-08120 mm · 238.2 m³/h · 127 Pa · DCsimilar duty
LWAD12038MD-08120 mm · 238.2 m³/h · 127 Pa · DCsimilar duty
LWAD12038HD-08120 mm · 238.2 m³/h · 127 Pa · DCsimilar duty
LWAD12038LM-14120 mm · 238.2 m³/h · 152 Pa · DCsimilar duty
LWAD12038MM-14120 mm · 238.2 m³/h · 152 Pa · DCsimilar dutySee all AC Cross Flow Fans · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for cross flow fans — on our main site.
Solutions
- Home appliance coolingHoods, ovens, dryers, air conditioners
- Commercial HVACAHU, rooftop, fan coil, air curtain