- ImpellerØ600 mm23.6 in
- Max airflow4,100 m³/h2,413 CFM
- Max static pressure500 Pa2.01 in. wg
- Voltage220-50/380-50 V
- Speed1,420 rpm
- Input power780 W1.05 hp
- Noise71 dB(A)
LWDA600S(T)-B05 Rectangular Inline Centrifugal Duct Fan Ø600 mm
Ø600 mm | AC | Max airflow 4,100 m³/h | Max static pressure 500 Pa | 71 dB(A)
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Dimensional drawing LWDA600S(T)-B05

Files for LWDA600S(T)-B05: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWDA600S(T)-B05
LWDA600S(T)-B05 is a LONGWELL Rectangular Inline Centrifugal Duct Fan, impeller Ø600 mm, rated 220-50/380-50 V AC, maximum airflow 4,100 m³/h, maximum static pressure 500 Pa, noise 71 dB(A), input power 780 W.
Technical data
| Model | LWDA600S(T)-B05 |
|---|---|
| Series | LWDA600 |
| Motor type | AC |
| Rated voltage | 220-50/380-50 V |
| Current | 3.6 A |
| Input power | 780 W |
| Speed | 1,420 rpm |
| Max. airflow | 4,100 m³/h |
| Max. static pressure | 500 Pa |
| Noise | 71 dB(A) |
| Impeller diameter | Ø600 mm |
Nameplate values; final selection is confirmed at the duty point and by project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWDA600S(T)-B05
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Alternatives with the same impeller (Ø600 mm · AC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWDA600S(T)-B05 this model | 4,100 m³/h | 500 Pa | 1,420 rpm | 780 W | 71 dB(A) | 220-50/380-50 V | |
| LWDA600S(T)-B03 | 2,150 m³/h | 230 Pa | 950 rpm | 328 W | 60 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-B06 | 2,600 m³/h | 255 Pa | 950 rpm | 328 W | 60 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-D04 | 2,880 m³/h | 220 Pa | 930 rpm | 656 W | 65 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-B01 | 2,950 m³/h | 500 Pa | 1,390 rpm | 634 W | 68 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-D02 | 3,200 m³/h | 180 Pa | 960 rpm | 360 W | 60 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-B04 | 3,400 m³/h | 580 Pa | 1,390 rpm | 714 W | 70 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-D03 | 3,840 m³/h | 500 Pa | 1,410 rpm | 1,428 W | 70 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-B02 | 4,000 m³/h | 480 Pa | 1,420 rpm | 714 W | 69 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-D06 | 4,300 m³/h | 230 Pa | 950 rpm | 656 W | 62 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-D01 | 4,600 m³/h | 380 Pa | 1,380 rpm | 740 W | 68 dB(A) | 220-50/380-50 V | View |
| LWDA600S(T)-D05 | 5,900 m³/h | 500 Pa | 1,380 rpm | 1,268 W | 71 dB(A) | 220-50/380-50 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWDA600 seriesSame impeller, different speed grade or wiring
LWDA600S(T)-B01Ø600 mm · 2,950 m³/h · 500 Pa · ACsame series
LWDA600S(T)-B02Ø600 mm · 4,000 m³/h · 480 Pa · ACsame series
LWDA600S(T)-B03Ø600 mm · 2,150 m³/h · 230 Pa · ACsame series
LWDA600S(T)-B04Ø600 mm · 3,400 m³/h · 580 Pa · ACsame series
LWDA600S(T)-B06Ø600 mm · 2,600 m³/h · 255 Pa · ACsame series
LWDA600S(T)-D01Ø600 mm · 4,600 m³/h · 380 Pa · ACsame seriesAdjacent sizesOne size up when airflow is short, one size down when it is too much
LWDA500S(T)-D01Ø500 mm · 4,400 m³/h · 300 Pa · ACadjacent size
LWDA500S(T)-D04Ø500 mm · 2,300 m³/h · 180 Pa · ACadjacent size
LWDA500S(T)-D03Ø500 mm · 3,240 m³/h · 450 Pa · ACadjacent size
LWDA500S(T)-D02Ø500 mm · 2,800 m³/h · 170 Pa · ACadjacent size
LWDA500S(T)-B04Ø500 mm · 3,400 m³/h · 400 Pa · ACadjacent size
LWDA500S(T)-B03Ø500 mm · 2,300 m³/h · 380 Pa · ACadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWT-1125-014,100 m³/h · 1,700 Pa · ACsimilar duty
LWT-1125-024,100 m³/h · 1,700 Pa · ACsimilar duty
LWDD10-10-ECØ254 mm · 4,102 m³/h · 608 Pa · ECsimilar duty
LWBA2D315-188NT-17Ø315 mm · 4,120 m³/h · 1,082 Pa · ACsimilar duty
LWBA4E400-138NS-09Ø400 mm · 4,120 m³/h · 494 Pa · ACsimilar duty
LWBA4D400-138NT-10Ø400 mm · 4,120 m³/h · 494 Pa · ACsimilar dutySee all Inline Duct Fans · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for inline duct fans — on our main site.
Solutions
- Residential ventilationERV / HRV, bathroom and duct fans
- Commercial HVACAHU, rooftop, fan coil, air curtain