• Frame size60 mm2.4 in
  • Max airflow8.4 m³/h5 CFM
  • Max static pressure104.54 Pa0.42 in. wg
  • Voltage24 V
  • Speed4,500 rpm
  • Input power2.88 W
  • Noise39 dB(A)

LWFD6018MM-02B.S DC Centrifugal Blower 60 mm

60 mm | DC | Max airflow 8.4 m³/h | Max static pressure 104.54 Pa | 39 dB(A)

SKU: LWFD6018MM-02B.S Categories: , ,
  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWFD6018MM-02B.S2 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Dimensional drawing LWFD6018MM-02B.S

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWFD6018MM-02B.S Dimensional drawing

Files for LWFD6018MM-02B.S: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWFD6018MM-02B.S

LWFD6018MM-02B.S is a LONGWELL DC Centrifugal Blower, frame 60 mm, rated 24 V DC, maximum airflow 8.4 m³/h, maximum static pressure 104.54 Pa, noise 39 dB(A), input power 2.88 W.

Technical data

Model LWFD6018MM-02B.S
Series LWFD6018
Motor type DC
Rated voltage 24 V
Current 0.12 A
Input power 2.88 W
Speed 4,500 rpm
Max. airflow 8.4 m³/h
Max. static pressure 104.54 Pa
Noise 39 dB(A)
Frame size 60 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWFD6018MM-02B.S

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same frame size (60 mm · DC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWFD6018MM-02B.S this model 8.4 m³/h104.54 Pa 4,500 rpm2.88 W39 dB(A)24 V
LWFD6015ML-06 5.3 m³/h63.5 Pa 3,000 rpm2.4 W26.5 dB(A)24 V View
LWFD6015LL-06 5.3 m³/h63.5 Pa 3,000 rpm1.8 W26.5 dB(A)12 V View
LWFD6015MM-07 5.9 m³/h88.4 Pa 3,600 rpm3.12 W29.8 dB(A)24 V View
LWFD6015LM-07 5.9 m³/h88.4 Pa 3,600 rpm2.16 W29.8 dB(A)12 V View
LWFD6018ML-03B.S 6.6 m³/h62.37 Pa 3,500 rpm1.92 W34 dB(A)24 V View
LWFD6018LL-03B.S 6.6 m³/h62.37 Pa 3,500 rpm1.8 W34 dB(A)12 V View
LWFD6018KL-02B.S 6.6 m³/h62.37 Pa 3,500 rpm1.2 W34 dB(A)5 V View
LWFD6015MH-08 6.9 m³/h118.5 Pa 4,200 rpm3.6 W32.5 dB(A)24 V View
LWFD6015MH-09 8.3 m³/h176 Pa 5,000 rpm4.8 W38 dB(A)24 V View
LWFD6015LH-09 8.3 m³/h176 Pa 5,000 rpm3.6 W38 dB(A)12 V View
LWFD6018LM-02B.S 8.4 m³/h104.54 Pa 4,500 rpm2.4 W39 dB(A)12 V View
LWFD6018KM-01B.S 8.4 m³/h104.54 Pa 4,500 rpm1.8 W39 dB(A)5 V View
LWFD6018MH-01B.S 10.2 m³/h176.81 Pa 5,500 rpm4.8 W43 dB(A)24 V View
LWFD6018LH-01B.S 10.2 m³/h176.81 Pa 5,500 rpm3.6 W43 dB(A)12 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for cooling fans & blowers — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote