- ImpellerØ120 mm4.7 in
- Max airflow278 m³/h164 CFM
- Max static pressure124 Pa0.50 in. wg
- Voltage220 V
- Speed1,000 rpm
- Input power34 W
LWGE120S-01 EC Gas Burner Blower Ø120 mm
Ø120 mm | EC | Max airflow 278 m³/h | Max static pressure 124 Pa
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Dimensional drawing LWGE120S-01

Files for LWGE120S-01: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWGE120S-01
LWGE120S-01 is a LONGWELL EC Gas Burner Blower, impeller Ø120 mm, rated 220 V EC, maximum airflow 278 m³/h, maximum static pressure 124 Pa, input power 34 W.
Technical data
| Model | LWGE120S-01 |
|---|---|
| Series | LWGE120 |
| Motor type | EC |
| Rated voltage | 220 V |
| Frequency | 50 Hz |
| Current | 0.18 A |
| Input power | 34 W |
| Speed | 1,000 rpm |
| Max. airflow | 278 m³/h |
| Max. static pressure | 124 Pa |
| Impeller diameter | Ø120 mm |
Nameplate values; final selection is confirmed at the duty point and by project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWGE120S-01
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWGE118U-04Ø118 mm · 110 m³/h · 3,500 Pa · ECadjacent size
LWGD118M-01Ø118 mm · 95 m³/h · 2,500 Pa · DCadjacent size
LWGE118S-05Ø118 mm · 105 m³/h · 2,781 Pa · ECadjacent size
LWGE118S-03Ø118 mm · 120 m³/h · 3,800 Pa · ECadjacent size
LWGA117S-01Ø117 mm · 100 m³/h · 309 Pa · ACadjacent size
LWGD130M-01Ø130 mm · 124 m³/h · 2,060 Pa · DCadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWAA2D165S-5MNW-01Ø165 mm · 278 m³/h · ACsimilar duty
LWFA2E120-092DS-02Ø120 mm · 278 m³/h · 350 Pa · ACsimilar duty
LWFA2E133-092SS-02Ø133 mm · 278 m³/h · 464 Pa · ACsimilar duty
LWFA2E133-092NS-02Ø133 mm · 278 m³/h · 464 Pa · ACsimilar duty
LWGE140U-01Ø140 mm · 278 m³/h · 124 Pa · ECsimilar duty
LWCD-301082MN-06Ø30 mm · 279 m³/h · 21 Pa · DCsimilar dutySee all Gas Blowers · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for gas blowers — on our main site.