AC Axial Fans

AC external-rotor axial fans for fixed-speed duties where speed control is not required and first cost matters. Single- and three-phase voltages, Ø145–800 mm, metal or plastic impellers, guard / plate / wall-ring mounting options. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point203 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAA2D145S-5MNW-01 LWAA2D145S-5MNW-01AC Ø145 mm 268 see curve 50 46 2,800 380 Details
LWAA2D145S-5MNW-02 LWAA2D145S-5MNW-02AC Ø145 mm 309 see curve 35 49 3,200 380 Details
LWAA2D165S-5MNW-01 LWAA2D165S-5MNW-01AC Ø165 mm 278 see curve 50 47 2,800 380 Details
LWAA2D165S-5MNW-02 LWAA2D165S-5MNW-02AC Ø165 mm 330 see curve 35 50 3,200 380 Details
LWAA2D185S-7MNW-03 LWAA2D185S-7MNW-03AC Ø185 mm 670 see curve 55 51 2,400 380 Details
LWAA2D185S-7MNW-04 LWAA2D185S-7MNW-04AC Ø185 mm 742 see curve 75 52 2,700 380 Details
LWAA2D200S-7MEB-05 LWAA2D200S-7MEB-05AC Ø200 mm 906 see curve 65 53 2,300 380 Details
LWAA2D200S-7MEB-06 LWAA2D200S-7MEB-06AC Ø200 mm 1,009 see curve 70 55 2,400 380 Details
LWAA2D200S-7MKW-09 LWAA2D200S-7MKW-09AC Ø200 mm 906 see curve 65 58 2,300 380/400 Details
LWAA2D200S-7MKW-10 LWAA2D200S-7MKW-10AC Ø200 mm 1,009 see curve 70 60 2,400 380/400 Details
LWAA2D200S-7MNW-01 LWAA2D200S-7MNW-01AC Ø200 mm 906 see curve 65 53 2,300 380 Details
LWAA2D200S-7MNW-02 LWAA2D200S-7MNW-02AC Ø200 mm 1,009 see curve 80 55 2,600 380 Details
LWAA2D230S-5MNW-01 LWAA2D230S-5MNW-01AC Ø230 mm 1,288 see curve 90 59 2,700 380 Details
LWAA2D230S-5MNW-02 LWAA2D230S-5MNW-02AC Ø230 mm 1,391 see curve 120 61 2,950 380 Details
LWAA2D250S-5MEB-03 LWAA2D250S-5MEB-03AC Ø250 mm 1,648 see curve 100 65 2,500 380 Details
LWAA2D250S-5MEB-04 LWAA2D250S-5MEB-04AC Ø250 mm 1,648 see curve 100 65 2,500 380 Details
LWAA2D250S-5MKW-11 LWAA2D250S-5MKW-11AC Ø250 mm 1,648 see curve 100 66 2,500 380 Details
LWAA2D250S-5MKW-12 LWAA2D250S-5MKW-12AC Ø250 mm 1,854 see curve 130 67 2,600 380 Details
LWAA2D300S-5MBW-05 LWAA2D300S-5MBW-05AC Ø300 mm 3,090 see curve 270 72 2,750 380 Details
LWAA2D300S-5MBW-06 LWAA2D300S-5MBW-06AC Ø300 mm 3,296 see curve 400 73 3,100 380 Details
LWAA2D300S-5MEW-05 LWAA2D300S-5MEW-05AC Ø300 mm 3,090 see curve 270 72 2,750 380/400 Details
LWAA2D300S-5MEW-06 LWAA2D300S-5MEW-06AC Ø300 mm 3,296 see curve 400 73 3,100 380/400 Details
LWAA2E185S-7MNW-01 LWAA2E185S-7MNW-01AC Ø185 mm 670 see curve 55 51 2,400 220/230 Details
LWAA2E185S-7MNW-02 LWAA2E185S-7MNW-02AC Ø185 mm 742 see curve 75 52 2,700 220/230 Details
LWAA2E200S-7MEB-03 LWAA2E200S-7MEB-03AC Ø200 mm 906 see curve 65 53 2,300 380/400 Details
LWAA2E200S-7MEB-04 LWAA2E200S-7MEB-04AC Ø200 mm 1,009 see curve 80 55 2,600 230 Details
LWAA2E200S-7MKW-07 LWAA2E200S-7MKW-07AC Ø200 mm 906 see curve 60 58 2,250 230 Details
LWAA2E200S-7MKW-08 LWAA2E200S-7MKW-08AC Ø200 mm 1,009 see curve 75 60 2,800 230 Details
LWAA2E250S-5MEB-01 LWAA2E250S-5MEB-01AC Ø250 mm 1,648 84 110 65 2,500 220/230 Details
LWAA2E250S-5MEB-02 LWAA2E250S-5MEB-02AC Ø250 mm 1,545 see curve 130 65 2,600 220/230 Details
LWAA2E250S-5MEW-22 LWAA2E250S-5MEW-22AC Ø250 mm 1,627 see curve 100 2,550 220 Details
LWAA2E250S-5MKW-09 LWAA2E250S-5MKW-09AC Ø250 mm 1,648 see curve 90 66 2,600 220/230 Details
LWAA2E250S-5MKW-10 LWAA2E250S-5MKW-10AC Ø250 mm 1,854 see curve 115 67 2,900 220/230 Details
LWAA2E250S-7MEB-15 LWAA2E250S-7MEB-15AC Ø250 mm 2,060 see curve 130 67 2,700 220/230 Details
LWAA2E250S-7MEB-16 LWAA2E250S-7MEB-16AC Ø250 mm 2,318 see curve 170 69 2,900 220/230 Details
LWAA2E250S-7MEW-15 LWAA2E250S-7MEW-15AC Ø250 mm 2,060 see curve 130 67 2,700 230 Details
LWAA2E250S-7MEW-16 LWAA2E250S-7MEW-16AC Ø250 mm 2,060 see curve 130 69 2,700 230 Details
LWAA2E300S-5MBW-07 LWAA2E300S-5MBW-07AC Ø300 mm 3,090 see curve 270 72 2,750 230 Details
LWAA2E300S-5MBW-08 LWAA2E300S-5MBW-08AC Ø300 mm 3,502 see curve 400 73 3,000 230 Details
LWAA2E300S-5MEW-07 LWAA2E300S-5MEW-07AC Ø300 mm 3,090 391 270 72 2,750 220 Details
Certifications for this product line
RoHS
View certificates →

AC Axial Fans — selection guide

AC Axial Fans: 203 models, impellers Ø145–910 mm, maximum airflow 268–31,106 m³/h, static pressure to 391 Pa, AC motors, across 54 series. 1 of them carry a measured P-Q curve and 201 a dimensional drawing.

LWAA AC axial fans are external-rotor fans for fixed-speed duties from Ø145 to Ø910 mm. The code tells the configuration: LWAA4E400S-5MEW is a 4-pole single-phase (E; D = three-phase) Ø400 mm fan. Pole count sets the speed and therefore the pressure and noise: 2-pole for the small Ø145–250 mm sizes, 4-pole for Ø250–550 mm, 6- and 8-pole for the large Ø600–910 mm fans. Supply is 220 / 230 V single-phase or 380 / 400 V three-phase, with 60 Hz and 480 V variants on some sizes.

Most models are IP54, rated −30 to +60 °C, with cold-rolled-steel impellers and maintenance-free ball bearings. Because no electronics are involved, these are the fans specified where the duty is constant and first cost decides — condensers, dry coolers and simple ventilation.

How to select from this range

  1. Pick the diameter for airflow and the pole count for pressure: at the same Ø450 mm a 4-pole fan delivers roughly twice the airflow of a 6-pole fan at about 6 dB(A) more noise.
  2. Choose single-phase (E) for equipment sold to end users and three-phase (D) for plant with a 380 / 400 V supply.
  3. Use the coil pressure drop, not free-air airflow, when reading the curve.
  4. Voltage-controllable versions allow simple step control; for continuous modulation move to the EC line on the same mounting dimensions.

Where these fans are used

  • Condensers and dry coolers
  • Cold-room evaporators
  • Heat-pump outdoor units
  • Wall and roof ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — AC Axial Fans

What is the difference between E and D in the LWAA code?

E is single-phase 220 / 230 V, D is three-phase 380 / 400 V. Both use the same impeller and mounting, so a unit can be offered in either supply without re-tooling.

Which LWAA sizes have the most variants?

Ø400 and Ø450 mm (LWAA4E400 / 4D400 / 4E450 / 4D450) with 9–13 versions each, followed by Ø250 and Ø350 mm — these are the condenser and heat-pump sizes that ship fastest.

Can AC axial fans be speed-controlled?

Voltage control (transformer or triac) works on many single-phase sizes with reduced airflow; for proportional control, feedback and part-load efficiency use the LWAE3G EC fan of the same diameter.

Related selections

Scroll to Top
RFQ list