Impeller Ø178–254 mm
Commercial Centrifugal Blowers — Impeller Ø178–254 mm: 12 models. Filter by airflow, static pressure, voltage and motor platform, compare specifications side by side and add models to your RFQ.
| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWDD10-10-ECEC | Ø254 mm | 2,923 | 608 | — | — | 1,440 | 220 | Details |
![]() |
LWDD10-8-ECEC | Ø254 mm | 785 | 528 | — | — | 1,440 | 220 | Details |
![]() |
LWDD7-5-ECEC | Ø178 mm | 852 | 304 | — | — | 1,440 | 220 | Details |
![]() |
LWDD7-7-ECEC | Ø178 mm | 1,923 | 321 | 350 | — | 1,440 | 220 | Details |
![]() |
LWDD8-7-ECEC | Ø203 mm | 2,734 | 467 | 585 | — | 1,440 | 220 | Details |
![]() |
LWDD8-8-ECEC | Ø203 mm | 898 | 417 | — | — | 1,440 | 220 | Details |
![]() |
LWDD9-7-ECEC | Ø229 mm | 363 | 486 | — | — | 1,440 | 220 | Details |
![]() |
LWDD9-9-ECEC | Ø229 mm | 139 | 587 | — | — | 1,440 | 220 | Details |
![]() |
LWFA-E-200-01AC | Ø200 mm | 1,000 | 305 | — | 58 | — | — | Details |
![]() |
LWFA-E-225-01AC | Ø225 mm | 2,300 | 325 | — | 65 | — | 220 | Details |
![]() |
LWFA-E-250-01AC | Ø250 mm | 2,500 | 380 | — | 70 | — | — | Details |
![]() |
LWFA-E-250-02AC | Ø250 mm | 2,100 | 215 | — | 64 | — | — | Details |
Impeller Ø178–254 mm — selection guide
Impeller Ø178–254 mm: 12 models, impellers Ø178–254 mm, maximum airflow 139–2,923 m³/h, static pressure to 608 Pa, EC and AC motors, across 1 series. 12 of them carry a measured P-Q curve and 12 a dimensional drawing.
The compact commercial blowers — Ø178 to Ø254 mm — are the units in kitchen hoods, small ventilation boxes and ovens: LWFA-E-200 / 225 / 250 EC direct-drive blowers and the LWDD10 AC blower, 139–2,923 m³/h at 215–608 Pa, on 220 V. Eight of the twelve models are EC with 0–10 V speed control.
How to select from this range
- Rate on total pressure at the outlet flange, including hood filters.
- Choose EC for hoods with variable extraction, AC for fixed duty.
Where these fans are used
- Kitchen extraction hoods
- Compact ventilation boxes
- Ovens and warming cabinets
Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — Impeller Ø178–254 mm
Which compact commercial blowers are EC?
LWFA-E-200, 225 and 250 (8 models) with 0–10 V control; the LWDD10 is AC.