ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWFD7515KH-02 LWFD7515KH-02DC 75 mm 10.8 148 2.5 40.7 3,500 5 Details
LWFD7515KL-04 LWFD7515KL-04DC 75 mm 7.8 75 2 33.4 2,500 5 Details
LWFD7515KM-03 LWFD7515KM-03DC 75 mm 9 109 2.25 37.3 3,000 5 Details
LWFD7515KX-01 LWFD7515KX-01DC 75 mm 11.4 165 3 41.9 3,700 5 Details
LWFD7515LD-05 LWFD7515LD-05DC 75 mm 6 48 1.8 28.5 2,000 12 Details
LWFD7515LH-02 LWFD7515LH-02DC 75 mm 10.8 148 3.12 40.7 3,500 12 Details
LWFD7515LL-04 LWFD7515LL-04DC 75 mm 7.8 75 2.4 33.4 2,500 12 Details
LWFD7515LM-03 LWFD7515LM-03DC 75 mm 9 109 2.64 37.3 3,000 12 Details
LWFD7515LX-01 LWFD7515LX-01DC 75 mm 11.4 165 3.6 41.9 3,700 12 Details
LWFD7515MD-05 LWFD7515MD-05DC 75 mm 6 48 2.4 28.5 2,000 24 Details
LWFD7515MH-02 LWFD7515MH-02DC 75 mm 10.8 148 3.84 40.7 3,500 24 Details
LWFD7515ML-04 LWFD7515ML-04DC 75 mm 7.8 75 2.88 33.4 2,500 24 Details
LWFD7515MM-03 LWFD7515MM-03DC 75 mm 9 109 3.36 37.3 3,000 24 Details
LWFD7515MX-01 LWFD7515MX-01DC 75 mm 11.4 165 4.8 41.9 3,700 24 Details
LWFD7525HD-05 LWFD7525HD-05DC 75 mm 13.2 84 4.8 37.9 2,500 48 Details
LWFD7525HH-02 LWFD7525HH-02DC 75 mm 21.6 215 12 48.1 4,000 48 Details
LWFD7525HL-04 LWFD7525HL-04DC 75 mm 16.2 121 7.2 41.9 3,000 48 Details
LWFD7525HM-03 LWFD7525HM-03DC 75 mm 18.6 164 9.6 45.2 3,500 48 Details
LWFD7525HX-01 LWFD7525HX-01DC 75 mm 24 272 14.4 50.7 4,500 48 Details
LWFD7525LD-05 LWFD7525LD-05DC 75 mm 13.2 84 3.6 37.9 2,500 12 Details
LWFD7525LH-02 LWFD7525LH-02DC 75 mm 21.6 215 7.2 48.1 4,000 12 Details
LWFD7525LL-04 LWFD7525LL-04DC 75 mm 16.2 121 4.8 41.9 3,000 12 Details
LWFD7525LM-03 LWFD7525LM-03DC 75 mm 18.6 164 6 45.2 3,500 12 Details
LWFD7525LX-01 LWFD7525LX-01DC 75 mm 24 272 8.4 50.7 4,500 12 Details
LWFD7525MD-05 LWFD7525MD-05DC 75 mm 13.2 84 4.8 37.9 2,500 24 Details
LWFD7525MH-02 LWFD7525MH-02DC 75 mm 21.6 215 8.4 48.1 4,000 24 Details
LWFD7525ML-04 LWFD7525ML-04DC 75 mm 16.2 121 6 41.9 3,000 24 Details
LWFD7525MM-03 LWFD7525MM-03DC 75 mm 18.6 164 7.2 45.2 3,500 24 Details
LWFD7525MX-01 LWFD7525MX-01DC 75 mm 24 272 9.6 50.7 4,500 24 Details
LWFD7530HD-05 LWFD7530HD-05DC 75 mm 15 95 4.8 37.8 2,500 48 Details
LWFD7530HH-02 LWFD7530HH-02DC 75 mm 24 242 12 48 4,000 48 Details
LWFD7530HL-04 LWFD7530HL-04DC 75 mm 18 136 7.2 41.8 3,000 48 Details
LWFD7530HM-03 LWFD7530HM-03DC 75 mm 21 185 9.6 45.1 3,500 48 Details
LWFD7530HX-01 LWFD7530HX-01DC 75 mm 27 306 14.4 50.6 4,500 48 Details
LWFD7530LD-05 LWFD7530LD-05DC 75 mm 15 95 3.6 37.8 2,500 12 Details
LWFD7530LH-02 LWFD7530LH-02DC 75 mm 24 242 7.2 48 4,000 12 Details
LWFD7530LL-04 LWFD7530LL-04DC 75 mm 18 136 4.8 41.8 3,000 12 Details
LWFD7530LM-03 LWFD7530LM-03DC 75 mm 21 185 6 45.1 3,500 12 Details
LWFD7530LX-01 LWFD7530LX-01DC 75 mm 27 306 8.4 50.6 4,500 12 Details
LWFD7530MD-05 LWFD7530MD-05DC 75 mm 15 95 4.8 37.8 2,500 24 Details

DC Centrifugal Blowers — selection guide

DC Centrifugal Blowers: 179 models, frame sizes 40–120 mm, maximum airflow 2–79 m³/h, static pressure to 570 Pa, DC motors, across 12 series. 150 of them carry a measured P-Q curve and 179 a dimensional drawing.

DC centrifugal blowers (LWFD) push air through a narrow outlet at higher static pressure than an axial fan of the same size: frames Ø40, 50, 60, 75, 97 and 120 mm (LWFD4010 to LWFD12032), 2.4–80 m³/h at 23–570 Pa, on 5 / 12 / 24 / 48 V. Each frame has 14–15 variants across voltages and speed grades. They are the fans for ducted cooling paths — heatsinks, battery packs, laser and medical modules, respiratory devices — where the air has to be directed rather than blown across an enclosure.

How to select from this range

  1. Use a blower where the air path has significant resistance (heatsink fins, ducts, filters); an axial fan stalls there.
  2. Match the outlet size and direction to the duct; blowers are handed.
  3. Choose the frame by pressure need: Ø75–120 mm reach 400–570 Pa, Ø40–60 mm 200–400 Pa.

Where these fans are used

  • Heatsink and duct cooling in electronics
  • Battery packs and chargers
  • Medical and respiratory devices
  • Laser and optical modules

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — DC Centrifugal Blowers

When should I use a DC blower instead of an axial fan?

When the air must pass through a channel with resistance — a finned heatsink, a duct, a filter — a blower keeps airflow where an axial fan of the same size would stall. At free air the axial fan moves more.

Which blower frames are ETL listed?

The DC centrifugal blower line is ETL listed (Intertek control no. 5022563) to UL 507 / CSA C22.2 No. 113 for 12 / 24 / 48 V.

Related selections

Scroll to Top
RFQ list