DC Centrifugal Blowers

Filter by duty point179 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWFD7530MH-02 LWFD7530MH-02DC 75 mm 24 242 8.4 48 4,000 24 Details
LWFD7530ML-04 LWFD7530ML-04DC 75 mm 18 136 6 41.8 3,000 24 Details
LWFD7530MM-03 LWFD7530MM-03DC 75 mm 21 185 7.2 45.1 3,500 24 Details
LWFD7530MX-01 LWFD7530MX-01DC 75 mm 27 306 9.6 50.6 4,500 24 Details
LWFD9733HD-05 LWFD9733HD-05DC 97 mm 21.6 53 4.8 32.4 1,500 48 Details
LWFD9733HH-02 LWFD9733HH-02DC 97 mm 43.8 212 14.4 47.5 3,000 48 Details
LWFD9733HL-04 LWFD9733HL-04DC 97 mm 29.4 94 7.2 38.7 2,000 48 Details
LWFD9733HM-03 LWFD9733HM-03DC 97 mm 36.6 147 9.6 43.5 2,500 48 Details
LWFD9733HX-01 LWFD9733HX-01DC 97 mm 51 288 19.2 50.8 3,500 48 Details
LWFD9733LD-05 LWFD9733LD-05DC 97 mm 21.6 53 3.6 32.4 1,500 12 Details
LWFD9733LH-02 LWFD9733LH-02DC 97 mm 43.8 212 9.6 47.5 3,000 12 Details
LWFD9733LL-04 LWFD9733LL-04DC 97 mm 29.4 94 4.8 38.7 2,000 12 Details
LWFD9733LM-03 LWFD9733LM-03DC 97 mm 36.6 147 7.2 43.5 2,500 12 Details
LWFD9733LX-01 LWFD9733LX-01DC 97 mm 51 288 12 50.8 3,500 12 Details
LWFD9733MD-05 LWFD9733MD-05DC 97 mm 21.6 53 4.8 32.4 1,500 24 Details
LWFD9733MH-02 LWFD9733MH-02DC 97 mm 43.8 212 12 47.5 3,000 24 Details
LWFD9733ML-04 LWFD9733ML-04DC 97 mm 29.4 94 7.2 38.7 2,000 24 Details
LWFD9733MM-03 LWFD9733MM-03DC 97 mm 36.6 147 9.6 43.5 2,500 24 Details
LWFD9733MX-01 LWFD9733MX-01DC 97 mm 51 288 14.4 50.8 3,500 24 Details

DC Centrifugal Blowers — selection guide

DC Centrifugal Blowers: 179 models, frame sizes 40–120 mm, maximum airflow 2–79 m³/h, static pressure to 570 Pa, DC motors, across 12 series. 150 of them carry a measured P-Q curve and 179 a dimensional drawing.

DC centrifugal blowers (LWFD) push air through a narrow outlet at higher static pressure than an axial fan of the same size: frames Ø40, 50, 60, 75, 97 and 120 mm (LWFD4010 to LWFD12032), 2.4–80 m³/h at 23–570 Pa, on 5 / 12 / 24 / 48 V. Each frame has 14–15 variants across voltages and speed grades. They are the fans for ducted cooling paths — heatsinks, battery packs, laser and medical modules, respiratory devices — where the air has to be directed rather than blown across an enclosure.

How to select from this range

  1. Use a blower where the air path has significant resistance (heatsink fins, ducts, filters); an axial fan stalls there.
  2. Match the outlet size and direction to the duct; blowers are handed.
  3. Choose the frame by pressure need: Ø75–120 mm reach 400–570 Pa, Ø40–60 mm 200–400 Pa.

Where these fans are used

  • Heatsink and duct cooling in electronics
  • Battery packs and chargers
  • Medical and respiratory devices
  • Laser and optical modules

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — DC Centrifugal Blowers

When should I use a DC blower instead of an axial fan?

When the air must pass through a channel with resistance — a finned heatsink, a duct, a filter — a blower keeps airflow where an axial fan of the same size would stall. At free air the axial fan moves more.

Which blower frames are ETL listed?

The DC centrifugal blower line is ETL listed (Intertek control no. 5022563) to UL 507 / CSA C22.2 No. 113 for 12 / 24 / 48 V.