Cooling Fans & Blowers

Filter by duty point879 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAD12038LL-15 LWAD12038LL-15DC 120 mm 204.6 112 8.4 48.5 3,000 12 Details
LWAD12038LM-03 LWAD12038LM-03DC 120 mm 284.4 133 12 52.4 3,600 12 Details
LWAD12038LM-06 LWAD12038LM-06DC 120 mm 297.6 199 14.4 60 5,000 12 Details
LWAD12038LM-14 LWAD12038LM-14DC 120 mm 238.2 152 8.4 51.8 3,500 12 Details
LWAD12038LX-01 LWAD12038LX-01DC 120 mm 361.2 210 42 58.5 4,600 12 Details
LWAD12038LX-04 LWAD12038LX-04DC 120 mm 357.6 286 42 64 6,000 12 Details
LWAD12038LX-09 LWAD12038LX-09DC 120 mm 408.6 448 42 63.5 6,000 12 Details
LWAD12038LX-10 LWAD12038LX-10DC 120 mm 374.4 376 42 61.6 5,500 12 Details
LWAD12038LX-11 LWAD12038LX-11DC 120 mm 340.8 311 42 59.5 5,000 12 Details
LWAD12038LX-12 LWAD12038LX-12DC 120 mm 306.6 252 42 57.3 4,500 12 Details
LWAD12038MD-08 LWAD12038MD-08DC 120 mm 238.2 127 12 55.2 4,000 24 Details
LWAD12038MD-16 LWAD12038MD-16DC 120 mm 170.4 78 4.8 44.5 2,500 24 Details
LWAD12038MH-02 LWAD12038MH-02DC 120 mm 331.8 181 24 55.7 4,200 24 Details
LWAD12038MH-05 LWAD12038MH-05DC 120 mm 327.6 240 24 62.1 5,500 24 Details
LWAD12038MH-13 LWAD12038MH-13DC 120 mm 272.4 199 14.4 54.7 4,000 24 Details
LWAD12038ML-07 LWAD12038ML-07DC 120 mm 268.2 161 14.4 57.8 4,500 24 Details
LWAD12038ML-15 LWAD12038ML-15DC 120 mm 204.6 112 7.2 48.5 3,000 24 Details
LWAD12038MM-03 LWAD12038MM-03DC 120 mm 284.4 133 14.4 52.4 3,600 24 Details
LWAD12038MM-06 LWAD12038MM-06DC 120 mm 297.6 199 19.2 60 5,000 24 Details
LWAD12038MM-14 LWAD12038MM-14DC 120 mm 238.2 152 10.8 51.8 3,500 24 Details
LWAD12038MX-01 LWAD12038MX-01DC 120 mm 361.2 210 48 58.5 4,600 24 Details
LWAD12038MX-04 LWAD12038MX-04DC 120 mm 357.6 286 28.8 64 6,000 24 Details
LWAD12038MX-09 LWAD12038MX-09DC 120 mm 408.6 448 48 63.5 6,000 24 Details
LWAD12038MX-10 LWAD12038MX-10DC 120 mm 374.4 376 48 61.6 5,500 24 Details
LWAD12038MX-11 LWAD12038MX-11DC 120 mm 340.8 311 48 59.5 5,000 24 Details
LWAD12038MX-12 LWAD12038MX-12DC 120 mm 306.6 252 48 57.3 4,500 24 Details
LWAD17238HX-01 LWAD17238HX-01DC 172 mm 508.8 186 38.4 57.4 3,000 48 Details
LWAD17238HX-02 LWAD17238HX-02DC 172 mm 424.2 129 19.2 53.4 2,500 48 Details
LWAD17238HX-03 LWAD17238HX-03DC 172 mm 339.6 83 14.4 48.6 2,000 48 Details
LWAD17238MX-01 LWAD17238MX-01DC 172 mm 508.8 186 36 57.4 3,000 24 Details
LWAD17238MX-02 LWAD17238MX-02DC 172 mm 424.2 129 19.2 53.4 2,500 24 Details
LWAD17238MX-03 LWAD17238MX-03DC 172 mm 339.6 83 12 48.6 2,000 24 Details
LWAD17251HH-03 LWAD17251HH-03DC 172 mm 436.2 206 57.6 58.2 3,500 48 Details
LWAD17251HH-08 LWAD17251HH-08DC 172 mm 645.6 387 57.6 71 5,000 48 Details
LWAD17251HL-05 LWAD17251HL-05DC 172 mm 311.4 105 28.8 50.9 2,500 48 Details
LWAD17251HL-10 LWAD17251HL-10DC 172 mm 516.6 248 28.8 66.2 4,000 48 Details
LWAD17251HM-04 LWAD17251HM-04DC 172 mm 373.8 151 48 54.9 3,000 48 Details
LWAD17251HM-09 LWAD17251HM-09DC 172 mm 580.8 314 48 68.8 4,500 48 Details
LWAD17251HX-01 LWAD17251HX-01DC 172 mm 560.4 340 96 63.7 4,500 48 Details
LWAD17251HX-02 LWAD17251HX-02DC 172 mm 498 269 76.8 61.1 4,000 48 Details

Cooling Fans & Blowers — selection guide

Cooling Fans & Blowers: 879 models, frame sizes 24–254 mm, maximum airflow 2–4,800 m³/h, static pressure to 2,650 Pa, DC, AC and EC motors, across 54 series. 157 of them carry a measured P-Q curve and 864 a dimensional drawing.

This is the compact end of the catalogue: 879 models for cooling electronics, cabinets and equipment. DC axial fans (LWAD) run from 25 × 25 mm to 200 mm frame with thicknesses from 10 to 60 mm, DC centrifugal blowers (LWFD) from Ø40 to Ø120 mm for pushing air through heatsinks and ducts, EC cooling fans (LWAE) from 60 to 254 mm on a 100–240 V universal AC input, and AC air blowers (LWB / LWT) for blow-off and air-knife duties up to 2,650 Pa.

Frames are UL94 V-0 plastic, supply voltages 5 / 12 / 24 / 48 V DC, and the model code carries frame, thickness and speed grade — LWAD8025HL is an 80 × 25 mm fan in the H-speed L-variant. Ball-bearing versions are the standard for continuous duty.

How to select from this range

  1. Estimate airflow from the heat load: Q (m³/h) ≈ 3 × P (W) / ΔT (K), then add the resistance of filters, grilles and heatsinks.
  2. Take the largest frame that fits — a bigger fan at lower speed gives the same airflow at far lower noise and longer life.
  3. Use a DC blower (LWFD) where air must be forced through a narrow channel or dense heatsink; an axial fan where the enclosure is open.
  4. Specify the control interface at the outset: PWM, tacho (FG), alarm (RD) or 0–10 V; it is part of the model code.
  5. Check life at the real ambient: ball-bearing L10 ratings are given at 40 °C and halve for roughly every 10 K above.

Where these fans are used

  • Power supplies, UPS and inverters
  • Telecom and server cabinets
  • EV chargers and battery packs
  • Medical and laboratory devices
  • Displays, projectors and appliances

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cooling Fans & Blowers

How do I decode a cooling fan model such as LWAD8025HL?

LWAD = DC axial cooling fan (LWFD = DC blower, LWAE = EC), 80 = frame in mm, 25 = thickness in mm, H = speed grade (H / M / L), L = variant. Within one frame the speed grades trade airflow against noise; the technical data lists each.

Which frame sizes are in stock as standard?

40, 50, 60, 70, 80, 92 and 120 mm frames carry the most variants (up to 15 per series), which is where samples ship fastest. 25, 30, 172 and 200 mm are also catalogued.

Can you supply PWM control and tacho output?

Yes. Most DC frames are available with PWM speed input, FG tacho signal and RD alarm output; EC models add 0–10 V control. Tell us the required signal when you request the sample.

Do the cooling fans have UL / CE documentation?

Frames are UL94 V-0, CE / RoHS declarations are available per model, and the DC centrifugal blower line is ETL listed (Intertek control no. 5022563).

Related selections

Scroll to Top
RFQ list