• ImpellerØ560 mm22.0 in
  • Max airflow9,270 m³/h5,456 CFM
  • Max static pressure464 Pa1.86 in. wg
  • Voltage380 V
  • Speed910 rpm
  • Input power900 W1.21 hp
  • Noise73 dB(A)

LWBA6D560-188NT-02 AC Backward Curved Centrifugal Fan Ø560 mm

Ø560 mm | AC | Max airflow 9,270 m³/h | Max static pressure 464 Pa | 73 dB(A)

  • Factory direct
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 18-month warranty
  • CE · RoHS · ETL on request
View RFQ →

Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWBA6D560-188NT-02 Dimensional drawing

Downloads for LWBA6D560-188NT-02

PDFDatasheet · 2.1 MB

Need a non-standard size or another format? Ask an engineer or search the download center.

LWBA6D560-188NT-02 is a LONGWELL AC Backward Curved Centrifugal Fan from the Backward Curved Centrifugal Fans range, impeller Ø560 mm, rated 380 V AC, maximum airflow 9,270 m³/h, maximum static pressure 464 Pa, noise 73 dB(A), input power 900 W. The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.

Technical data

Model LWBA6D560-188NT-02
Series LWBA6D560
Motor type AC
Phase 3-phase
Rated voltage 380 V
Frequency 50 Hz
Current 1.8 A
Input power 900 W
Speed 910 rpm
Max. airflow 9,270 m³/h
Max. static pressure 464 Pa
Noise 73 dB(A)
Ambient temperature -40 ~ 65 °C
Impeller diameter Ø560 mm
Rotor diameter 188
Impeller material Aluminum Alloy
Protection class IP54
Insulation class F
Bearing Maintenance-free ball bearings
Duty S1
Rotation Clockwise,seen on rotor

Typical applications

  • Air handling units (AHU) and rooftop units (RTU)
  • Data-center CRAH / CRAC units and fan walls
  • Dust extraction and process ventilation
  • Fan filter units and air purifiers

Series LWBA6D560: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.

Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.

Alternatives with the same impeller (Ø560 mm · AC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWBA6D560-188NT-02 this model 9,270 m³/h464 Pa 910 rpm900 W73 dB(A)380 V
LWBA6D560-188NT-04 9,270 m³/h464 Pa 910 rpm900 W73 dB(A)380 V View
LWBA4D560-188NT-03 11,330 m³/h948 Pa 1,350 rpm2,500 W85 dB(A)380 V View
LWBA4D560-188NT-05 13,125 m³/h798 Pa 1,350 rpm1,980 W83.9 dB(A)380 V View
LWBA4D560-188NT-01 13,287 m³/h948 Pa 1,340 rpm2,500 W85 dB(A)380 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice