Ø40 mm | AC | Max airflow 272 m³/h | Max static pressure 24 Pa | 38 dB(A)

Need a non-standard size or another format? Ask an engineer or search the download center.
LWCA-40920SN-06 is a LONGWELL AC Cross Flow Fan from the AC Cross Flow Fans range, impeller Ø40 mm, rated 230 V AC, maximum airflow 272 m³/h, maximum static pressure 24 Pa, noise 38 dB(A), input power 25 W. The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.
| Model | LWCA-40920SN-06 |
|---|---|
| Series | LWCA40920 |
| Motor type | AC |
| Phase | 1-phase |
| Inlet | Triple |
| Rated voltage | 230 V |
| Frequency | 50 Hz |
| Input power | 25 W |
| Speed | 2,200 rpm |
| Max. airflow | 272 m³/h |
| Max. static pressure | 24 Pa |
| Noise | 38 dB(A) |
| Ambient temperature | -25 ~ 60 °C |
| Impeller diameter | Ø40 mm |
| Outlet length | 920mm |
| Impeller material | Aluminum alloy |
| Insulation class | B/F/H |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
Series LWCA40920: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWCA-40920SN-06 this model | 272 m³/h | 24 Pa | 2,200 rpm | 25 W | 38 dB(A) | 230 V | |
| LWCA-40250SN-07 | 77 m³/h | 19 Pa | 2,400 rpm | 12 W | 30 dB(A) | 230 V | View |
| LWCA-40250UN-06 | 77 m³/h | 19 Pa | 2,400 rpm | 12 W | 30 dB(A) | 115 V | View |
| LWCA-40290SN-07 | 93 m³/h | 20 Pa | 2,400 rpm | 12 W | 30 dB(A) | 230 V | View |
| LWCA-40290UN-06 | 93 m³/h | 20 Pa | 2,400 rpm | 13 W | 30 dB(A) | 115 V | View |
| LWCA-40350SN-07 | 108 m³/h | 21 Pa | 2,400 rpm | 13 W | 31 dB(A) | 230 V | View |
| LWCA-40350UN-06 | 108 m³/h | 21 Pa | 2,400 rpm | 16 W | 31 dB(A) | 115 V | View |
| LWCA-40420SN-07 | 130 m³/h | 22 Pa | 2,400 rpm | 14 W | 32 dB(A) | 230 V | View |
| LWCA-40420UN-06 | 130 m³/h | 22 Pa | 2,400 rpm | 17 W | 32 dB(A) | 115 V | View |
| LWCA-40530SN-06 | 156 m³/h | 23 Pa | 2,200 rpm | 17 W | 34 dB(A) | 230 V | View |
| LWCA-40610SN-06 | 180 m³/h | 23 Pa | 2,200 rpm | 19 W | 35 dB(A) | 230 V | View |
| LWCA-40700SN-06 | 207 m³/h | 23 Pa | 2,200 rpm | 20 W | 37 dB(A) | 230 V | View |
| LWCA-40800SN-06 | 236 m³/h | 24 Pa | 2,200 rpm | 22 W | 37 dB(A) | 230 V | View |
| LWCA-40854SN-06 | 252 m³/h | 24 Pa | 2,200 rpm | 23 W | 37 dB(A) | 230 V | View |
| LWCA-401055SN-06 | 311 m³/h | 25 Pa | 2,200 rpm | 25 W | 38 dB(A) | 230 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
LWCA-43350SN-07Ø43 mm · 130 m³/h · 15 Pa · ACadjacent size
LWCA-43150UN-06Ø43 mm · 72 m³/h · 22 Pa · ACadjacent size
LWCA-4390SN-07Ø43 mm · 41 m³/h · 18 Pa · ACadjacent size
LWCA-4390UN-06Ø43 mm · 48 m³/h · 22 Pa · ACadjacent size
LWCA-43420SN-07Ø43 mm · 163 m³/h · 21 Pa · ACadjacent size
LWCD-43420MN-07Ø43 mm · 191 m³/h · 16 Pa · DCadjacent size
LWCD-40920MN-06Ø40 mm · 272 m³/h · 26 Pa · DCsimilar duty
LWAD12038LH-13120 mm · 272.4 m³/h · 199 Pa · DCsimilar duty
LWAD12038MH-13120 mm · 272.4 m³/h · 199 Pa · DCsimilar duty
LWAD12038HH-13120 mm · 272.4 m³/h · 199 Pa · DCsimilar duty
LWAD12025LH-08120 mm · 271.2 m³/h · 249 Pa · DCsimilar duty
LWAD12025MH-08120 mm · 271.2 m³/h · 249 Pa · DCsimilar dutySee all AC Cross Flow Fans · select by duty point