ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAD6020HH-02 LWAD6020HH-02DC 60 mm 50.4 102 6.72 47 7,000 48 Details
LWAD6020HL-04 LWAD6020HL-04DC 60 mm 36 52 4.8 39.7 5,000 48 Details
LWAD6020HM-03 LWAD6020HM-03DC 60 mm 43.2 75 5.76 43.7 6,000 48 Details
LWAD6020HX-01 LWAD6020HX-01DC 60 mm 57 133 7.68 49.9 8,000 48 Details
LWAD6020LD-05 LWAD6020LD-05DC 60 mm 27 33 2.4 34.8 4,000 12 Details
LWAD6020LH-02 LWAD6020LH-02DC 60 mm 48 102 6 46 6,700 12 Details
LWAD6020LL-04 LWAD6020LL-04DC 60 mm 34.2 52 3.6 39.7 5,000 12 Details
LWAD6020LM-03 LWAD6020LM-03DC 60 mm 43.2 75 4.8 43.7 6,000 12 Details
LWAD6020LX-01 LWAD6020LX-01DC 60 mm 57 133 6.6 49.9 8,000 12 Details
LWAD6020MD-05 LWAD6020MD-05DC 60 mm 28.8 33 2.4 34.8 4,000 24 Details
LWAD6020MH-02 LWAD6020MH-02DC 60 mm 50.4 102 6 47 7,000 24 Details
LWAD6020ML-04 LWAD6020ML-04DC 60 mm 36 52 3.6 39.7 5,000 24 Details
LWAD6020MM-03 LWAD6020MM-03DC 60 mm 43.2 75 4.8 43.7 6,000 24 Details
LWAD6020MX-01 LWAD6020MX-01DC 60 mm 57 133 7.2 49.9 8,000 24 Details
LWAD6025HD-06 LWAD6025HD-06DC 60 mm 34.2 41 4.8 34.6 4,000 48 Details
LWAD6025HH-03 LWAD6025HH-03DC 60 mm 60 125 12 46.8 7,000 48 Details
LWAD6025HL-05 LWAD6025HL-05DC 60 mm 43.2 64 7.2 39.4 5,000 48 Details
LWAD6025HM-04 LWAD6025HM-04DC 60 mm 51.6 92 9.6 43.4 6,000 48 Details
LWAD6025HX-01 LWAD6025HX-01DC 60 mm 85.8 256 19.2 54.5 10,000 48 Details
LWAD6025HX-02 LWAD6025HX-02DC 60 mm 77.4 207 19.2 52.2 9,000 48 Details
LWAD6025HX-03 LWAD6025HX-03DC 60 mm 68.4 164 19.2 49.7 8,000 48 Details
LWAD6025LD-06 LWAD6025LD-06DC 60 mm 34.2 41 3.6 34.6 4,000 12 Details
LWAD6025LH-03 LWAD6025LH-03DC 60 mm 60 125 7.2 46.8 7,000 12 Details
LWAD6025LL-05 LWAD6025LL-05DC 60 mm 43.2 64 4.8 39.4 5,000 12 Details
LWAD6025LM-04 LWAD6025LM-04DC 60 mm 51.6 92 6 43.4 6,000 12 Details
LWAD6025LX-01 LWAD6025LX-01DC 60 mm 85.8 256 14.4 54.5 10,000 12 Details
LWAD6025LX-02 LWAD6025LX-02DC 60 mm 77.4 207 14.4 52.2 9,000 12 Details
LWAD6025LX-03 LWAD6025LX-03DC 60 mm 68.4 164 14.4 49.7 8,000 12 Details
LWAD6025MD-06 LWAD6025MD-06DC 60 mm 34.2 41 4.8 34.6 4,000 24 Details
LWAD6025MH-03 LWAD6025MH-03DC 60 mm 60 125 8.4 46.8 7,000 24 Details
LWAD6025ML-05 LWAD6025ML-05DC 60 mm 43.2 64 6 39.4 5,000 24 Details
LWAD6025MM-04 LWAD6025MM-04DC 60 mm 51.6 92 7.2 43.4 6,000 24 Details
LWAD6025MX-01 LWAD6025MX-01DC 60 mm 85.8 256 14.4 54.5 10,000 24 Details
LWAD6025MX-02 LWAD6025MX-02DC 60 mm 77.4 207 14.4 52.2 9,000 24 Details
LWAD6025MX-03 LWAD6025MX-03DC 60 mm 68.4 164 14.4 49.7 8,000 24 Details
LWAD6038HD-05 LWAD6038HD-05DC 60 mm 51 84 5.76 45.5 5,500 48 Details
LWAD6038HH-02 LWAD6038HH-02DC 60 mm 79.2 200 13.44 54.9 8,500 48 Details
LWAD6038HL-04 LWAD6038HL-04DC 60 mm 60.6 117 7.2 49.1 6,500 48 Details
LWAD6038HM-03 LWAD6038HM-03DC 60 mm 70.2 155 9.6 52.2 7,500 48 Details
LWAD6038HX-01 LWAD6038HX-01DC 60 mm 88.8 249 19.2 57.3 9,500 48 Details

Cooling Fans & Blowers — selection guide

Cooling Fans & Blowers: 879 models, frame sizes 24–254 mm, maximum airflow 2–4,800 m³/h, static pressure to 2,650 Pa, DC, AC and EC motors, across 54 series. 157 of them carry a measured P-Q curve and 864 a dimensional drawing.

This is the compact end of the catalogue: 879 models for cooling electronics, cabinets and equipment. DC axial fans (LWAD) run from 25 × 25 mm to 200 mm frame with thicknesses from 10 to 60 mm, DC centrifugal blowers (LWFD) from Ø40 to Ø120 mm for pushing air through heatsinks and ducts, EC cooling fans (LWAE) from 60 to 254 mm on a 100–240 V universal AC input, and AC air blowers (LWB / LWT) for blow-off and air-knife duties up to 2,650 Pa.

Frames are UL94 V-0 plastic, supply voltages 5 / 12 / 24 / 48 V DC, and the model code carries frame, thickness and speed grade — LWAD8025HL is an 80 × 25 mm fan in the H-speed L-variant. Ball-bearing versions are the standard for continuous duty.

How to select from this range

  1. Estimate airflow from the heat load: Q (m³/h) ≈ 3 × P (W) / ΔT (K), then add the resistance of filters, grilles and heatsinks.
  2. Take the largest frame that fits — a bigger fan at lower speed gives the same airflow at far lower noise and longer life.
  3. Use a DC blower (LWFD) where air must be forced through a narrow channel or dense heatsink; an axial fan where the enclosure is open.
  4. Specify the control interface at the outset: PWM, tacho (FG), alarm (RD) or 0–10 V; it is part of the model code.
  5. Check life at the real ambient: ball-bearing L10 ratings are given at 40 °C and halve for roughly every 10 K above.

Where these fans are used

  • Power supplies, UPS and inverters
  • Telecom and server cabinets
  • EV chargers and battery packs
  • Medical and laboratory devices
  • Displays, projectors and appliances

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cooling Fans & Blowers

How do I decode a cooling fan model such as LWAD8025HL?

LWAD = DC axial cooling fan (LWFD = DC blower, LWAE = EC), 80 = frame in mm, 25 = thickness in mm, H = speed grade (H / M / L), L = variant. Within one frame the speed grades trade airflow against noise; the technical data lists each.

Which frame sizes are in stock as standard?

40, 50, 60, 70, 80, 92 and 120 mm frames carry the most variants (up to 15 per series), which is where samples ship fastest. 25, 30, 172 and 200 mm are also catalogued.

Can you supply PWM control and tacho output?

Yes. Most DC frames are available with PWM speed input, FG tacho signal and RD alarm output; EC models add 0–10 V control. Tell us the required signal when you request the sample.

Do the cooling fans have UL / CE documentation?

Frames are UL94 V-0, CE / RoHS declarations are available per model, and the DC centrifugal blower line is ETL listed (Intertek control no. 5022563).

Related selections

Scroll to Top
RFQ list