• ImpellerØ450 mm17.7 in
  • Max airflow7,828 m³/h4,607 CFM
  • Voltage220/230 V
  • Speed1,580 rpm
  • Input power750 W1.01 hp
  • Noise72 dB(A)

LWAA4E450S-5MEB-38 AC Axial Fan Ø450 mm

Ø450 mm | AC | Max airflow 7,828 m³/h | 72 dB(A)

SKU: LWAA4E450S-5MEB-38 Categories: , ,
  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWAA4E450S-5MEB-383 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Video LWAA4E450S-5MEB-38

Don’t Let Cooling Hold Your System Back. | LWAA4E450S-5MEB-22 · open in video library

Dimensional drawing LWAA4E450S-5MEB-38

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWAA4E450S-5MEB-38 Dimensional drawing

Files for LWAA4E450S-5MEB-38: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWAA4E450S-5MEB-38

LWAA4E450S-5MEB-38 is a LONGWELL AC Axial Fan, impeller Ø450 mm, rated 220/230 V AC, maximum airflow 7,828 m³/h, noise 72 dB(A), input power 750 W.

Technical data

Model LWAA4E450S-5MEB-38
Series LWAA4E450
Motor type AC
Rated voltage 220/230 V
Frequency 60 Hz
Current 3.45 A
Input power 750 W
Speed 1,580 rpm
Max. airflow 7,828 m³/h
Noise 72 dB(A)
Impeller diameter Ø450 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWAA4E450S-5MEB-38

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same impeller (Ø450 mm · AC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWAA4E450S-5MEB-38 this model 7,828 m³/hsee curve 1,580 rpm750 W72 dB(A)220/230 V
LWAA6E450S-5MEB-05 2,987 m³/hsee curve 920 rpm135 W56 dB(A)220/230 V View
LWAA6D450S-5MEB-08 3,502 m³/hsee curve 1,030 rpm140 W58 dB(A)380 V View
LWAA6E450S-5MEB-06 3,899 m³/hsee curve 920 rpm138 W55 dB(A)220/230 V View
LWAA4E450B-5MKB-22 4,635 m³/hsee curve 1,350 rpm250 W62 dB(A)220/230 V View
LWAA4D450S-5MEW-23 5,562 m³/hsee curve 1,390 rpm280 W—380 V View
LWAA4E450S-5MEW-22 5,562 m³/hsee curve 1,350 rpm280 W—220 V View
LWAA4E450S-5MEB-41 5,974 m³/hsee curve 1,350 rpm400 W62 dB(A)220/230 V View
LWAA4D450S-5MEB-43 5,974 m³/hsee curve 1,350 rpm400 W62 dB(A)380/400 V View
LWEA450S(T)M-163E 6,658 m³/h150 Pa 1,450 rpm550 W—220 V View
LWAA4E450S-5MEB-42 6,901 m³/hsee curve 1,500 rpm500 W64 dB(A)220/230 V View
LWAA4D450S-5MEB-44 6,901 m³/hsee curve 1,500 rpm500 W64 dB(A)380/400 V View
LWAA4D450S-5MEB-39 7,004 m³/hsee curve 1,350 rpm480 W68 dB(A)380/400 V View
LWAA4D450S-5MEB-40 7,725 m³/hsee curve 1,540 rpm730 W72 dB(A)380/400 V View
LWA-450(18")U(S)M-01 12,500 m³/h580 Pa 2,800 rpm1,500 W—110-120 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for axial fans — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote