• ImpellerØ220 mm8.7 in
  • Max airflow1,185 m³/h697 CFM
  • Max static pressure979 Pa3.93 in. wg
  • Voltage230 V
  • Speed3,250 rpm
  • Input power168 W
  • Noise70 dB(A)

LWBE3G220-072PS-03 EC Backward-Curved Centrifugal Fan With Bracket Ø220 mm

Ø220 mm | EC | Max airflow 1,185 m³/h | Max static pressure 979 Pa | 70 dB(A)

  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · ETL · RoHS
All files for LWBE3G220-072PS-033 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Dimensional drawing LWBE3G220-072PS-03

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWBE3G220-072PS-03 Dimensional drawing

Files for LWBE3G220-072PS-03: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWBE3G220-072PS-03

LWBE3G220-072PS-03 is a LONGWELL EC Backward-Curved Centrifugal Fan With Bracket, impeller Ø220 mm, rated 230 V EC, maximum airflow 1,185 m³/h, maximum static pressure 979 Pa, noise 70 dB(A), input power 168 W.

Technical data

Model LWBE3G220-072PS-03
Series LWBE3G220
Motor type EC
Rated voltage 230 V
Current 1.27 A
Input power 168 W
Speed 3,250 rpm
Max. airflow 1,185 m³/h
Max. static pressure 979 Pa
Noise 70 dB(A)
Impeller diameter Ø220 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Product-line certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO management-system certificate and the certificates whose model list covers this model. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

CE-LVDVoluntary certificates of conformity issued by KTS; the covered models are listed on each certificate.

CE-LVD certificate of conformity KB2206066L01 · LWBE3G — LONGWELL certificatePDFCE-LVD certificate of conformity KB2206066L01 · LWBE3G

ETLIntertek Authorization to Mark, control no. 5022563; the covered model ranges are stated on the document.

ETL Authorization to Mark · report 220400508HAN-001 · LWBE3G / LWDE3G / LWFE3G — LONGWELL certificatePDFETL Authorization to Mark · report 220400508HAN-001 · LWBE3G / LWDE3G / LWFE3G

RoHSVoluntary certificate of conformity issued by KTS; the covered models are listed on the certificate.

RoHS certificate of conformity KB2206068R01 · LWBE3G — LONGWELL certificatePDFRoHS certificate of conformity KB2206068R01 · LWBE3G

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWBE3G220-072PS-03

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same impeller (Ø220 mm · EC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWBE3G220-072PS-03 this model 1,185 m³/h979 Pa 3,250 rpm168 W70 dB(A)230 V
LWBE3G220-072PS-10 886 m³/h433 Pa 2,600 rpm75 W71 dB(A)230 V View
LWBE3G220-072NS-11 886 m³/h433 Pa 2,600 rpm75 W71 dB(A)230 V View
LWBE3G220-072PS-01 937 m³/h721 Pa 2,470 rpm86 W68 dB(A)230 V View
LWBE3G220-072NU-13 937.3 m³/h721 Pa 2,470 rpm86 W68 dB(A)115 V View
LWBE3G220-072NS-07 937.3 m³/h721 Pa 2,470 rpm86 W68 dB(A)230 V View
LWBE3G220-092PS-11 989 m³/h711 Pa 3,310 rpm145 W75 dB(A)230 V View
LWBE3G220-092NS-10 989 m³/h711 Pa 3,310 rpm145 W75 dB(A)230 V View
LWBE3G220-072NU-14 1,019.7 m³/h597.4 Pa 2,800 rpm115 W69 dB(A)115 V View
LWBE3G220-072NS-09 1,019.7 m³/h597.4 Pa 2,800 rpm115 W69 dB(A)230 V View
LWBE3G220-072PS-02 1,020 m³/h597 Pa 2,800 rpm115 W69 dB(A)230 V View
LWBE3G220-072NU-12 1,184.5 m³/h978.5 Pa 3,250 rpm168 W70 dB(A)115 V View
LWBE3G220-072NS-08 1,184.5 m³/h978.5 Pa 3,250 rpm168 W70 dB(A)230 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Other models in the LWBE3G220 seriesSame impeller, different speed grade or wiring

Adjacent sizesOne size up when airflow is short, one size down when it is too much

Alternatives at a similar dutySimilar airflow, different construction or motor platform

See all Backward Curved Centrifugal Fans  ·  select by duty point

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for centrifugal fans — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote