- ImpellerØ225 mm8.9 in
- Max airflow1,185 m³/h697 CFM
- Max static pressure670 Pa2.69 in. wg
- Voltage230 V
- Speed2,600 rpm
- Input power115 W
- Noise67 dB(A)
LWBE3G225-072PS-02 EC Backward-Curved Centrifugal Fan With Bracket Ø225 mm
Ø225 mm | EC | Max airflow 1,185 m³/h | Max static pressure 670 Pa | 67 dB(A)
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · ETL · RoHS
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Video LWBE3G225-072PS-02
Longwell EC Fan Test | LWBE3G225-072PS-02 · open in video library
LONGWELL 225mm EC Backward-Curved Centrifugal Fan LWBE3G225-072PS-03 | High-Efficiency & Low-Noise HVAC Solution · open in video library
Dimensional drawing LWBE3G225-072PS-02

Files for LWBE3G225-072PS-02: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWBE3G225-072PS-02
LWBE3G225-072PS-02 is a LONGWELL EC Backward-Curved Centrifugal Fan With Bracket, impeller Ø225 mm, rated 230 V EC, maximum airflow 1,185 m³/h, maximum static pressure 670 Pa, noise 67 dB(A), input power 115 W.
Technical data
| Model | LWBE3G225-072PS-02 |
|---|---|
| Series | LWBE3G225 |
| Motor type | EC |
| Rated voltage | 230 V |
| Current | 0.9 A |
| Input power | 115 W |
| Speed | 2,600 rpm |
| Max. airflow | 1,185 m³/h |
| Max. static pressure | 670 Pa |
| Noise | 67 dB(A) |
| Impeller diameter | Ø225 mm |
Nameplate values; final selection is confirmed at the duty point and by project verification.
Product-line certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO management-system certificate and the certificates whose model list covers this model. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateCE-LVDVoluntary certificates of conformity issued by KTS; the covered models are listed on each certificate.
PDFCE-LVD certificate of conformity KB2206066L01 · LWBE3GETLIntertek Authorization to Mark, control no. 5022563; the covered model ranges are stated on the document.
PDFETL Authorization to Mark · report 220400508HAN-001 · LWBE3G / LWDE3G / LWFE3GRoHSVoluntary certificate of conformity issued by KTS; the covered models are listed on the certificate.
PDFRoHS certificate of conformity KB2206068R01 · LWBE3GNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWBE3G225-072PS-02
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Alternatives with the same impeller (Ø225 mm · EC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWBE3G225-072PS-02 this model | 1,185 m³/h | 670 Pa | 2,600 rpm | 115 W | 67 dB(A) | 230 V | |
| LWBE3G225-072PS-01 | 1,009 m³/h | 618 Pa | 2,300 rpm | 85 W | 65 dB(A) | 230 V | View |
| LWBE3G225-072PS-11 | 1,112 m³/h | 433 Pa | 2,500 rpm | 80 W | 69 dB(A) | 230 V | View |
| LWBE3G225-072NS-10 | 1,112 m³/h | 433 Pa | 2,500 rpm | 80 W | 69 dB(A) | 230 V | View |
| LWBE3G225-072PS-03 | 1,313 m³/h | 1,030 Pa | 3,100 rpm | 170 W | 70 dB(A) | 230 V | View |
| LWBE3G225-072NU-16 | 1,313.25 m³/h | 1,030 Pa | 3,100 rpm | 170 W | 70 dB(A) | 115 V | View |
| LWBE3G225-092NS-10 | 1,359.6 m³/h | 906.4 Pa | 3,600 rpm | 230 W | 71 dB(A) | 230 V | View |
| LWBE3G225-092NU-17 | 1,359.6 m³/h | 906.4 Pa | 3,600 rpm | 230 W | 71 dB(A) | 115 V | View |
| LWBE3G225-092PS-04 | 1,360 m³/h | 906 Pa | 3,600 rpm | 230 W | 71 dB(A) | 230 V | View |
| LWBE3G225-092PS-12 | 1,528 m³/h | 683 Pa | 3,060 rpm | 170 W | 71.1 dB(A) | 230 V | View |
| LWBE3G225-092NS-11 | 1,528 m³/h | 683 Pa | 3,060 rpm | 170 W | 71 dB(A) | 230 V | View |
| LWBE3G225-092PS-13 | 1,545 m³/h | 731 Pa | 3,000 rpm | 160 W | 71 dB(A) | 230 V | View |
| LWBE3G225-092NS-12 | 1,545 m³/h | 731 Pa | 3,000 rpm | 160 W | 71 dB(A) | 230 V | View |
| LWBE3G225-092PS-07 | 1,630 m³/h | 839 Pa | 3,500 rpm | 315 W | 71 dB(A) | 230 V | View |
| LWBE3G225-092NS-13 | 1,630 m³/h | 839 Pa | 3,500 rpm | 315 W | 71 dB(A) | 230 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWBE3G225 seriesSame impeller, different speed grade or wiring
LWBE3G225-072NS-11Ø225 mm · 1,009.4 m³/h · 618 Pa · ECsame series
LWBE3G225-072NS-13Ø225 mm · 1,184.5 m³/h · 669.5 Pa · ECsame series
LWBE3G225-072NS-07Ø225 mm · 1,313.25 m³/h · 1,030 Pa · ECsame series
LWBE3G225-072NU-14Ø225 mm · 1,009.4 m³/h · 618 Pa · ECsame series
LWBE3G225-072NU-15Ø225 mm · 1,184.5 m³/h · 669.5 Pa · ECsame series
LWBE3G225-072NU-16Ø225 mm · 1,313.25 m³/h · 1,030 Pa · ECsame seriesAdjacent sizesOne size up when airflow is short, one size down when it is too much
LWBA2E220-092NS-05Ø220 mm · 999 m³/h · 515 Pa · ACadjacent size
LWBE3G220-072PS-10Ø220 mm · 886 m³/h · 433 Pa · ECadjacent size
LWBA2D220-092NT-07Ø220 mm · 999 m³/h · 515 Pa · ACadjacent size
LWBD3G220-092NH-05Ø220 mm · 1,030 m³/h · 577 Pa · DCadjacent size
LWBA2D220-092NT-06Ø220 mm · 937 m³/h · 484 Pa · ACadjacent size
LWBA2E220-092NS-04Ø220 mm · 937 m³/h · 484 Pa · ACadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWBA2E250-092NS-09Ø250 mm · 1,185 m³/h · 773 Pa · ACsimilar duty
LWBA2D250-092NT-11Ø250 mm · 1,185 m³/h · 773 Pa · ACsimilar duty
LWBA2E250-092NS-12Ø250 mm · 1,185 m³/h · 567 Pa · ACsimilar duty
LWBE3G220-072PS-03Ø220 mm · 1,185 m³/h · 979 Pa · ECsimilar duty
LWBE3G250-072PS-01Ø250 mm · 1,185 m³/h · 618 Pa · ECsimilar duty
LWBE3G220-072NS-08Ø220 mm · 1,184.5 m³/h · 978.5 Pa · ECsimilar dutySee all Backward Curved Centrifugal Fans · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for centrifugal fans — on our main site.
Solutions
- Commercial HVACAHU, rooftop, fan coil, air curtain
- FanGridsN+1 fan arrays for AHU retrofit
- Data center coolingCRAH, FanGrid, server rooms