  • ImpellerØ630 mm24.8 in
  • Max airflow21,100 m³/h12,419 CFM
  • Max static pressure1,071 Pa4.30 in. wg
  • Voltage400 V
  • Speed1,380 rpm
  • Input power2,955 W3.96 hp

LWBE3G630-188PT-02 EC Plug Fan Ø630 mm

Ø630 mm | EC | Max airflow 21,100 m³/h | Max static pressure 1,071 Pa

  • Factory direct
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 18-month warranty
  • CE · ETL · RoHS
View RFQ →
Engineering files (on request)

CAD files exist for this model and can be released for assembly checks in SolidWorks / CATIA / Creo / Inventor.

CAD models contain the blade geometry and are not downloadable. Tell us the project; an engineer sends the file after a short check, normally within 1 business day.

Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWBE3G630-188PT-02 Dimensional drawing
Performance curve (P-Q)Static pressure vs. airflow. Curve numbers correspond to supply voltage / speed grades.
LWBE3G630-188PT-02 Performance curve (P-Q)
Wiring diagramLead colours and terminal assignment; TK = motor thermal contact.
LWBE3G630-188PT-02 Wiring diagram

Downloads for LWBE3G630-188PT-02

PDFDatasheetDOCXDatasheet · 622 KB

Need a non-standard size or another format? Ask an engineer or search the download center.

LWBE3G630-188PT-02 is a LONGWELL EC Plug Fan from the Plug Fans (RLM Plenum Fans) range, impeller Ø630 mm, rated 400 V EC, maximum airflow 21,100 m³/h, maximum static pressure 1,071 Pa, input power 2,955 W. The EC motor integrates the drive electronics: stepless speed control by 0–10 V or PWM signal, speed feedback and high efficiency at part load.

Technical data

Model LWBE3G630-188PT-02
Series LWBE3G630
Motor type EC
Phase 3-phase
Rated voltage 400 V
Frequency 50 Hz
Current 6.5 A
Input power 2,955 W
Speed 1,380 rpm
Max. airflow 21,100 m³/h
Max. airflow (CFM) 12,411 CFM
Max. static pressure 1,071 Pa
Ambient temperature -25 ~ 60 °C
Storage temperature -25 ~ 70℃
Humidity 0 ~ 85% RH
Altitude < 1000m
Impeller diameter Ø630 mm
Rotor diameter 188
Impeller material Aluminum Alloy (Impeller)
Protection class IP54
Insulation class F
Bearing Maintenance-free deep groove ball bearings
Duty S1
Balance grade G6.3
Vibration standard JB/T 8689
Service life 40,000Hours(L10). At 40℃room, humidity 15%~65%RH
Speed control Control input 0~10VDC(RS485 external control box can be connected)
Control signal Control signal VSP voltage range 1.5±0.1VDC~9.5±0.2VDC(During normal operation, when the VSP voltage is below 0.9±0.1VDC, the motor switches from operating mode to standby mode)
Speed feedback Tach output: 15Pulse/R; FG internal open circuit output, external pull-up resistor R, pull-up voltage V+
Auxiliary output Output 10±0.3VDC, Max Current: 22mA
Communication LWRS485-04
Protection functions Current limiting protection, Over-temperature protection, Over-current protectionLocked-rotor protection, Input power supply lacks phase protection
Soft start Delay time <35 seconds to full speed

Typical applications

  • Air handling units (AHU) and rooftop units (RTU)
  • Data-center CRAH / CRAC units and fan walls
  • Dust extraction and process ventilation
  • Fan filter units and air purifiers

Series LWBE3G630: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.

Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.

Alternatives with the same impeller (Ø630 mm · EC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWBE3G630-188PT-02 this model 21,100 m³/h1,071 Pa 1,380 rpm2,955 W400 V
LWAE3G630TS-5MKW-09 12,566 m³/h258 Pa 930 rpm580 W75 dB(A)3 V View
LWAE3G630TS-5PEW-11 13,670 m³/h224 Pa 1,200 rpm887 W74 dB(A)380/400 V View
LWAE3G630TS-5MKW-08 13,905 m³/h256 Pa 1,020 rpm780 W74 dB(A)3 V View
LWAE3G630TT-5MNW-02 14,935 m³/h238 Pa 1,150 rpm800 W69 dB(A)380 V View
LWAE3G630TT-5MKW-06 14,935 m³/h238 Pa 1,250 rpm800 W69 dB(A)380 V View
LWAE3G630TT-5MEW-04 14,935 m³/h238 Pa 1,150 rpm800 W69 dB(A)380 V View
LWAE3G630TS-5MNW-01 14,935 m³/h238 Pa 1,150 rpm800 W69 dB(A)380 V View
LWAE3G630TS-5MKW-05 14,935 m³/h238 Pa 1,150 rpm800 W69 dB(A)380 V View
LWBE3G630-188PT-05 19,158 m³/h968 Pa 1,250 rpm3,600 W85 dB(A)400 V View
LWBE3G630-188PT-01 19,247 m³/h887 Pa 1,300 rpm2,195 W400 V View
LWBE3G630-188NT-06 19,247 m³/h887 Pa 1,300 rpm2,195 W66 dB(A)400 V View
LWBE3G630-188NT-07 21,100 m³/h1,071 Pa 1,380 rpm2,955 W85 dB(A)400 V View
LWBE3G630-188PT-04 21,742 m³/h1,677 Pa 1,780 rpm5,600 W400 V View
LWBE3G630-188NT-09 21,742 m³/h1,677 Pa 1,780 rpm5,600 W75 dB(A)400 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.