• ImpellerØ400 mm15.7 in
  • Max airflow1,080 m³/h636 CFM
  • Max static pressure240 Pa0.96 in. wg
  • Voltage220-50/380-50 V
  • Speed1,390 rpm
  • Input power260 W
  • Noise64 dB(A)

LWDA400S(T)-F01 Rectangular Inline Centrifugal Duct Fan Ø400 mm

Ø400 mm | AC | Max airflow 1,080 m³/h | Max static pressure 240 Pa | 64 dB(A)

SKU: LWDA400S(T)-F01 Categories: ,
  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWDA400S(T)-F012 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Dimensional drawing LWDA400S(T)-F01

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWDA400S(T)-F01 Dimensional drawing

Files for LWDA400S(T)-F01: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWDA400S(T)-F01

LWDA400S(T)-F01 is a LONGWELL Rectangular Inline Centrifugal Duct Fan, impeller Ø400 mm, rated 220-50/380-50 V AC, maximum airflow 1,080 m³/h, maximum static pressure 240 Pa, noise 64 dB(A), input power 260 W.

Technical data

Model LWDA400S(T)-F01
Series LWDA400
Motor type AC
Rated voltage 220-50/380-50 V
Current 1.08 A
Input power 260 W
Speed 1,390 rpm
Max. airflow 1,080 m³/h
Max. static pressure 240 Pa
Noise 64 dB(A)
Impeller diameter Ø400 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWDA400S(T)-F01

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same impeller (Ø400 mm · AC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWDA400S(T)-F01 this model 1,080 m³/h240 Pa 1,390 rpm260 W64 dB(A)220-50/380-50 V
LWDA400S(T)-F02 730 m³/h215 Pa 800 rpm147 W61 dB(A)220-50/380-50 V View
LWDA400S(T)-B01 1,250 m³/h245 Pa 1,180 rpm147 W63 dB(A)220-50/380-50 V View
LWDA400S(T)-D03 1,460 m³/h215 Pa 800 rpm294 W62 dB(A)220-50/380-50 V View
LWDA400S(T)-B02 1,600 m³/h300 Pa 1,400 rpm190 W64 dB(A)220-50/380-50 V View
LWDA400S(T)-D02 2,160 m³/h240 Pa 1,390 rpm520 W67 dB(A)220-50/380-50 V View
LWDA400S-D01 2,500 m³/h245 Pa 1,180 rpm294 W66 dB(A)220-50 V View
LWDA-400 (16")U-MWN-01 2,500 m³/hsee curve 1,780 rpm440 W75 dB(A)110-120 V View
LWDA-400 (16")U-MWN-03 2,500 m³/hsee curve 1,780 rpm440 W66 dB(A)110-120 V View
LWDA-400 (16")S-MWN-02 7,100 m³/hsee curve 2,940 rpm1,300 W83 dB(A)220-240 V View
LWDA-400 (16")S-MWN-04 7,100 m³/hsee curve 2,940 rpm1,300 W71 dB(A)220-240 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for inline duct fans — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote