| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWAA6D550S-5MEB-08AC | Ø550 mm | 7,210 | see curve | 440 | 66 | 1,090 | 380 | Details |
![]() |
LWAA6D600S-5MEB-04AC | Ø600 mm | 9,785 | see curve | 500 | 67 | 920 | 380 | Details |
![]() |
LWAA6D600S-5MEB-05AC | Ø600 mm | 10,197 | see curve | 650 | 69 | 1,070 | 380 | Details |
![]() |
LWAA6D630B-5MKB-12AC | Ø630 mm | 11,021 | see curve | 520 | 67 | 900 | 380/400 | Details |
![]() |
LWAA6D630B-5MKB-13AC | Ø630 mm | 12,154 | see curve | 740 | 69 | 1,050 | 380/400 | Details |
![]() |
LWAA6D630S-4MKB-10AC | Ø630 mm | 10,815 | see curve | 450 | 68 | 925 | 380 | Details |
![]() |
LWAA6D630S-5MEB-04AC | Ø630 mm | 11,021 | see curve | 520 | 67 | 900 | 380 | Details |
![]() |
LWAA6D630S-5MEB-05AC | Ø630 mm | 10,815 | see curve | 740 | 69 | 1,060 | 380 | Details |
![]() |
LWAA6D710S-5MEW-07AC | Ø710 mm | 17,510 | see curve | 1,200 | — | 920 | 380 | Details |
![]() |
LWAA6D710S-5MKB-06AC | Ø710 mm | 17,510 | see curve | 645 | 72.6 | 960 | 380 | Details |
![]() |
LWAA6D710S-7MEB-01AC | Ø710 mm | 17,510 | see curve | 1,100 | 75 | 900 | 380 | Details |
![]() |
LWAA6D710S-7MGB-03AC | Ø710 mm | 17,510 | see curve | 1,100 | 75 | 900 | 380 | Details |
![]() |
LWAA6D710S-7MKB-03AC | Ø710 mm | 17,510 | see curve | 1,100 | 75 | 900 | 380/400 | Details |
![]() |
LWAA6D800S-5MKB-03AC | Ø800 mm | 17,510 | see curve | 785 | 65 | 710 | 380 | Details |
![]() |
LWAA6D800S-5MKB-04AC | Ø800 mm | 23,999 | see curve | 1,780 | 78.9 | 920 | 380 | Details |
![]() |
LWAA6D800S-7MEB-01AC | Ø800 mm | 24,720 | see curve | 1,600 | 80 | 900 | 380 | Details |
![]() |
LWAA6D800S-7MEB-02AC | Ø800 mm | 25,750 | see curve | 1,850 | 80 | 900 | 380/400 | Details |
![]() |
LWAA6D800S-7MEB-05AC | Ø800 mm | 20,703 | see curve | 1,600 | — | 960 | 380 | Details |
![]() |
LWAA6D800S-7MKB-02AC | Ø800 mm | 25,750 | see curve | 1,850 | 80 | 900 | 380 | Details |
![]() |
LWAA6D900S-5MKB-01AC | Ø900 mm | 31,106 | see curve | 2,600 | 80 | 940 | 380 | Details |
![]() |
LWAA6D910S-5MEB-03AC | Ø910 mm | 26,780 | see curve | 2,450 | — | 920 | 380 | Details |
![]() |
LWAA6E350S-5MEB-05AC | Ø350 mm | 1,607 | see curve | 75 | 53 | 950 | 220/230 | Details |
![]() |
LWAA6E350S-5MEB-06AC | Ø350 mm | 1,854 | see curve | 83 | 54 | 1,100 | 220/230 | Details |
![]() |
LWAA6E400S-5MEB-05AC | Ø400 mm | 2,678 | see curve | 100 | 49 | 1,350 | 220/230 | Details |
![]() |
LWAA6E400S-5MEB-06AC | Ø400 mm | 3,090 | see curve | 120 | 52 | 1,100 | 220/230 | Details |
![]() |
LWAA6E450S-5MEB-05AC | Ø450 mm | 2,987 | see curve | 135 | 56 | 920 | 220/230 | Details |
![]() |
LWAA6E450S-5MEB-06AC | Ø450 mm | 3,899 | see curve | 138 | 55 | 920 | 220/230 | Details |
![]() |
LWAA6E500S-5MEB-05AC | Ø500 mm | 4,450 | see curve | 220 | 65 | 900 | 220/230 | Details |
![]() |
LWAA6E500S-5MEB-06AC | Ø500 mm | 4,944 | see curve | 250 | 66 | 1,020 | 220/230 | Details |
![]() |
LWAA6E550S-5MEB-05AC | Ø550 mm | 6,695 | see curve | 320 | 62 | 900 | 220/230 | Details |
![]() |
LWAA6E550S-5MEB-06AC | Ø550 mm | 7,210 | see curve | 465 | 66 | 1,060 | 220/230 | Details |
![]() |
LWAA6E600B-5MKB-07AC | Ø600 mm | 9,785 | see curve | 500 | 67 | 910 | 220/230 | Details |
![]() |
LWAA6E600B-5MKB-08AC | Ø600 mm | 10,197 | see curve | 640 | 69 | 1,080 | 220/230 | Details |
![]() |
LWAA6E600S-5MEB-02AC | Ø600 mm | 9,785 | see curve | 500 | 67 | 910 | 220/230 | Details |
![]() |
LWAA6E600S-5MEB-03AC | Ø600 mm | 10,197 | see curve | 640 | 69 | 1,080 | 220/230 | Details |
![]() |
LWAA6E630S-4MKB-09AC | Ø630 mm | 10,815 | see curve | 450 | 68 | 925 | 230 | Details |
![]() |
LWAA6E630S-5MEB-02AC | Ø630 mm | 11,021 | see curve | 520 | 67 | 900 | 220/230 | Details |
![]() |
LWAA6E630S-5MEB-03AC | Ø630 mm | 11,536 | see curve | 705 | 69 | 1,050 | 220/230 | Details |
![]() |
LWAA8D630S-5MEB-07AC | Ø630 mm | 7,210 | see curve | 250 | 60 | 680 | 380 | Details |
![]() |
LWAA8D710S-7MEB-02AC | Ø710 mm | 12,360 | see curve | 700 | 67 | 700 | 380 | Details |
AC Axial Fans — selection guide
AC Axial Fans: 203 models, impellers Ø145–910 mm, maximum airflow 268–31,106 m³/h, static pressure to 391 Pa, AC motors, across 54 series. 1 of them carry a measured P-Q curve and 201 a dimensional drawing.
LWAA AC axial fans are external-rotor fans for fixed-speed duties from Ø145 to Ø910 mm. The code tells the configuration: LWAA4E400S-5MEW is a 4-pole single-phase (E; D = three-phase) Ø400 mm fan. Pole count sets the speed and therefore the pressure and noise: 2-pole for the small Ø145–250 mm sizes, 4-pole for Ø250–550 mm, 6- and 8-pole for the large Ø600–910 mm fans. Supply is 220 / 230 V single-phase or 380 / 400 V three-phase, with 60 Hz and 480 V variants on some sizes.
Most models are IP54, rated −30 to +60 °C, with cold-rolled-steel impellers and maintenance-free ball bearings. Because no electronics are involved, these are the fans specified where the duty is constant and first cost decides — condensers, dry coolers and simple ventilation.
How to select from this range
- Pick the diameter for airflow and the pole count for pressure: at the same Ø450 mm a 4-pole fan delivers roughly twice the airflow of a 6-pole fan at about 6 dB(A) more noise.
- Choose single-phase (E) for equipment sold to end users and three-phase (D) for plant with a 380 / 400 V supply.
- Use the coil pressure drop, not free-air airflow, when reading the curve.
- Voltage-controllable versions allow simple step control; for continuous modulation move to the EC line on the same mounting dimensions.
Where these fans are used
- Condensers and dry coolers
- Cold-room evaporators
- Heat-pump outdoor units
- Wall and roof ventilation
Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — AC Axial Fans
What is the difference between E and D in the LWAA code?
E is single-phase 220 / 230 V, D is three-phase 380 / 400 V. Both use the same impeller and mounting, so a unit can be offered in either supply without re-tooling.
Which LWAA sizes have the most variants?
Ø400 and Ø450 mm (LWAA4E400 / 4D400 / 4E450 / 4D450) with 9–13 versions each, followed by Ø250 and Ø350 mm — these are the condenser and heat-pump sizes that ship fastest.
Can AC axial fans be speed-controlled?
Voltage control (transformer or triac) works on many single-phase sizes with reduced airflow; for proportional control, feedback and part-load efficiency use the LWAE3G EC fan of the same diameter.