AC Axial Fans

Filter by duty point203 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAA4E400S-5MEB-01 LWAA4E400S-5MEB-01AC Ø400 mm 3,811 see curve 180 60 1,350 220/230 Details
LWAA4E400S-5MEB-02 LWAA4E400S-5MEB-02AC Ø400 mm 4,223 see curve 260 62 1,580 220/230 Details
LWAA4E400S-5MEB-09 LWAA4E400S-5MEB-09AC Ø400 mm 4,532 see curve 230 62 1,350 220/230 Details
LWAA4E400S-5MEB-10 LWAA4E400S-5MEB-10AC Ø400 mm 5,150 see curve 280 64 1,600 220/230 Details
LWAA4E400S-5MEB-13 LWAA4E400S-5MEB-13AC Ø400 mm 4,429 see curve 225 58 1,380 220/230 Details
LWAA4E400S-5MEB-14 LWAA4E400S-5MEB-14AC Ø400 mm 4,491 see curve 210 68 1,600 120 Details
LWAA4E400S-5MEB-15 LWAA4E400S-5MEB-15AC Ø400 mm 4,429 see curve 225 58 1,380 380 Details
LWAA4E400S-5MEB-16 LWAA4E400S-5MEB-16AC Ø400 mm 4,893 see curve 310 60 1,400 380 Details
LWAA4E400S-5MEB-21 LWAA4E400S-5MEB-21AC Ø400 mm 4,069 see curve 180 59 1,350 220/230 Details
LWAA4E400S-5MKB-17 LWAA4E400S-5MKB-17AC Ø400 mm 4,429 see curve 225 58 1,380 220/230 Details
LWAA4E400S-5MKB-18 LWAA4E400S-5MKB-18AC Ø400 mm 4,069 see curve 180 68 1,400 220/230 Details
LWAA4E420S-5MEB-01 LWAA4E420S-5MEB-01AC Ø420 mm 5,459 see curve 300 65 1,350 220/230 Details
LWAA4E420S-5MEB-02 LWAA4E420S-5MEB-02AC Ø420 mm 5,974 see curve 400 68 1,580 220/230 Details
LWAA4E450B-5MKB-22 LWAA4E450B-5MKB-22AC Ø450 mm 4,635 see curve 250 62 1,350 220/230 Details
LWAA4E450S-5MEB-01 LWAA4E450S-5MEB-01AC Ø450 mm 4,635 see curve 250 62 1,350 220/230 Details
LWAA4E450S-5MEB-02 LWAA4E450S-5MEB-02AC Ø450 mm 4,944 see curve 280 64 1,600 220/230 Details
LWAA4E450S-5MEB-09 LWAA4E450S-5MEB-09AC Ø450 mm 7,004 see curve 480 66 1,350 230 Details
LWAA4E450S-5MEB-11 LWAA4E450S-5MEB-11AC Ø450 mm 5,768 see curve 380 64 1,350 220/230 Details
LWAA4E450S-5MEB-13 LWAA4E450S-5MEB-13AC Ø450 mm 7,025 see curve 400 72 1,420 230 Details
LWAA4E450S-5MEB-14 LWAA4E450S-5MEB-14AC Ø450 mm 5,150 see curve 270 58 1,350 220/230 Details
LWAA4E450S-5MEB-15 LWAA4E450S-5MEB-15AC Ø450 mm 5,665 see curve 330 60 1,400 220/230 Details
LWAA4E450S-5MEW-22 LWAA4E450S-5MEW-22AC Ø450 mm 5,562 see curve 280 1,350 220 Details
LWAA4E450S-5MKB-18 LWAA4E450S-5MKB-18AC Ø450 mm 5,459 see curve 270 58 1,350 220/230 Details
LWAA4E450S-5MKB-19 LWAA4E450S-5MKB-19AC Ø450 mm 5,665 see curve 330 60 1,400 220/230 Details
LWAA4E500B-5MKB-12 LWAA4E500B-5MKB-12AC Ø500 mm 6,850 see curve 420 69 1,320 220/230 Details
LWAA4E500S-5MEB-01 LWAA4E500S-5MEB-01AC Ø500 mm 6,695 see curve 420 69 1,320 220/230 Details
LWAA4E500S-5MEB-02 LWAA4E500S-5MEB-02AC Ø500 mm 7,004 see curve 500 70 1,450 220/230 Details
LWAA4E500S-5MEB-09 LWAA4E500S-5MEB-09AC Ø500 mm 9,270 see curve 800 80 1,320 220/230 Details
LWAA4E550B-5MKB-09 LWAA4E550B-5MKB-09AC Ø550 mm 8,034 see curve 550 73 1,320 220/230 Details
LWAA4E550S-5MEB-01 LWAA4E550S-5MEB-01AC Ø550 mm 8,034 see curve 550 73 1,320 220/230 Details
LWAA4E550S-5MEB-02 LWAA4E550S-5MEB-02AC Ø550 mm 8,755 see curve 550 74 1,450 220/230 Details
LWAA6D350S-5MEB-07 LWAA6D350S-5MEB-07AC Ø350 mm 1,607 see curve 70 53 920 380 Details
LWAA6D350S-5MEB-08 LWAA6D350S-5MEB-08AC Ø350 mm 1,854 see curve 80 54 1,050 380 Details
LWAA6D400S-5MEB-07 LWAA6D400S-5MEB-07AC Ø400 mm 2,678 see curve 100 49 930 380 Details
LWAA6D400S-5MEB-08 LWAA6D400S-5MEB-08AC Ø400 mm 3,090 see curve 120 52 1,100 380 Details
LWAA6D450S-5MEB-07 LWAA6D450S-5MEB-07AC Ø450 mm 2,987 see curve 135 56 910 380 Details
LWAA6D450S-5MEB-08 LWAA6D450S-5MEB-08AC Ø450 mm 3,502 see curve 140 58 1,030 380 Details
LWAA6D500S-5MEB-07 LWAA6D500S-5MEB-07AC Ø500 mm 4,450 see curve 220 65 900 380 Details
LWAA6D500S-5MEB-08 LWAA6D500S-5MEB-08AC Ø500 mm 4,944 see curve 250 66 1,100 380 Details
LWAA6D550S-5MEB-07 LWAA6D550S-5MEB-07AC Ø550 mm 6,695 see curve 320 62 910 380 Details
Certifications for this product line
RoHS
View certificates →

AC Axial Fans — selection guide

AC Axial Fans: 203 models, impellers Ø145–910 mm, maximum airflow 268–31,106 m³/h, static pressure to 391 Pa, AC motors, across 54 series. 1 of them carry a measured P-Q curve and 201 a dimensional drawing.

LWAA AC axial fans are external-rotor fans for fixed-speed duties from Ø145 to Ø910 mm. The code tells the configuration: LWAA4E400S-5MEW is a 4-pole single-phase (E; D = three-phase) Ø400 mm fan. Pole count sets the speed and therefore the pressure and noise: 2-pole for the small Ø145–250 mm sizes, 4-pole for Ø250–550 mm, 6- and 8-pole for the large Ø600–910 mm fans. Supply is 220 / 230 V single-phase or 380 / 400 V three-phase, with 60 Hz and 480 V variants on some sizes.

Most models are IP54, rated −30 to +60 °C, with cold-rolled-steel impellers and maintenance-free ball bearings. Because no electronics are involved, these are the fans specified where the duty is constant and first cost decides — condensers, dry coolers and simple ventilation.

How to select from this range

  1. Pick the diameter for airflow and the pole count for pressure: at the same Ø450 mm a 4-pole fan delivers roughly twice the airflow of a 6-pole fan at about 6 dB(A) more noise.
  2. Choose single-phase (E) for equipment sold to end users and three-phase (D) for plant with a 380 / 400 V supply.
  3. Use the coil pressure drop, not free-air airflow, when reading the curve.
  4. Voltage-controllable versions allow simple step control; for continuous modulation move to the EC line on the same mounting dimensions.

Where these fans are used

  • Condensers and dry coolers
  • Cold-room evaporators
  • Heat-pump outdoor units
  • Wall and roof ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — AC Axial Fans

What is the difference between E and D in the LWAA code?

E is single-phase 220 / 230 V, D is three-phase 380 / 400 V. Both use the same impeller and mounting, so a unit can be offered in either supply without re-tooling.

Which LWAA sizes have the most variants?

Ø400 and Ø450 mm (LWAA4E400 / 4D400 / 4E450 / 4D450) with 9–13 versions each, followed by Ø250 and Ø350 mm — these are the condenser and heat-pump sizes that ship fastest.

Can AC axial fans be speed-controlled?

Voltage control (transformer or triac) works on many single-phase sizes with reduced airflow; for proportional control, feedback and part-load efficiency use the LWAE3G EC fan of the same diameter.

Related selections

Scroll to Top
RFQ list