EC Axial Fans
EC axial fans integrate an electronically commutated motor and drive: stepless 0–10 V / PWM speed control, speed feedback and high part-load efficiency, ready for BMS / SCADA integration. Ø200–900 mm. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.
Browse by size
Browse by series
| Model | Size | Max airflowm³/h | Max static pressurePa | PowerW | NoisedB(A) | Speedrpm | VoltageV | ||
|---|---|---|---|---|---|---|---|---|---|
![]() |
LWAE3G200SS-5PEW-03EC | Ø200 mm | 886 | see curve | 80 | 54 | 2,600 | 220 | Details |
![]() |
LWAE3G200SS-5PGW-05EC | Ø200 mm | 886 | see curve | 80 | 54 | 2,600 | 220 | Details |
![]() |
LWAE3G200SS-5PNW-01EC | Ø200 mm | 886 | 238 | 80 | 54 | 2,600 | 220/230 | Details |
![]() |
LWAE3G200SS-5PNW-03EC | Ø200 mm | 886 | 238 | 80 | 54 | 2,600 | 230 | Details |
![]() |
LWAE3G200SS-5PNW-05EC | Ø200 mm | 886 | 238 | 80 | 54 | 2,600 | 230 | Details |
![]() |
LWAE3G200SS-7MEW-09EC | Ø200 mm | 1,051 | 247 | 55 | 60 | 3,000 | 220/230 | Details |
![]() |
LWAE3G200SS-7MGW-11EC | Ø200 mm | 958 | see curve | 55 | 60 | 3,300 | 220/230 | Details |
![]() |
LWAE3G200SS-7MNW-07EC | Ø200 mm | 958 | 320 | 55 | 60 | 3,300 | 220/230 | Details |
![]() |
LWAE3G200SS-7PKW-14EC | Ø200 mm | 1,009 | 279 | 55 | 60 | 2,780 | 220/230 | Details |
![]() |
LWAE3G200SS-7PKW-16EC | Ø200 mm | 1,391 | 395 | 115 | 64 | 3,600 | 220/230 | Details |
![]() |
LWAE3G200SS-7PNW-13EC | Ø200 mm | 1,009 | 279 | 55 | 60 | 2,780 | 220/230 | Details |
![]() |
LWAE3G200SS-7PNW-15EC | Ø200 mm | 1,391 | 395 | 115 | 64 | 3,600 | 220/230 | Details |
![]() |
LWAE3G200ST-5PEW-04EC | Ø200 mm | 886 | see curve | 80 | 54 | 2,600 | 220 | Details |
![]() |
LWAE3G200ST-5PGW-06EC | Ø200 mm | 886 | see curve | 80 | 54 | 2,600 | 220 | Details |
![]() |
LWAE3G200ST-5PNW-02EC | Ø200 mm | 886 | 238 | 80 | 54 | 2,600 | 220/230 | Details |
![]() |
LWAE3G200ST-5PNW-04EC | Ø200 mm | 886 | 238 | 80 | 54 | 2,600 | 230 | Details |
![]() |
LWAE3G200ST-5PNW-06EC | Ø200 mm | 886 | 238 | 80 | 54 | 2,600 | 230 | Details |
![]() |
LWAE3G200ST-7MEW-10EC | Ø200 mm | 958 | 320 | 55 | 60 | 3,300 | 220/230 | Details |
![]() |
LWAE3G200ST-7MGW-12EC | Ø200 mm | 958 | 320 | 55 | 60 | 3,300 | 220/230 | Details |
![]() |
LWAE3G200ST-7MNW-08EC | Ø200 mm | 958 | 320 | 55 | 60 | 3,300 | 220/230 | Details |
![]() |
LWAE3G250SS-7MEW-03EC | Ø250 mm | 1,751 | 290 | 170 | 69 | 3,150 | 220/230 | Details |
![]() |
LWAE3G250SS-7MGW-05EC | Ø250 mm | 1,751 | 290 | 135 | 69 | 3,150 | 220/230 | Details |
![]() |
LWAE3G250SS-7MNW-01EC | Ø250 mm | 1,751 | 290 | 135 | 69 | 3,150 | 220/230 | Details |
![]() |
LWAE3G250SS-7PKW-08EC | Ø250 mm | 1,627 | 214 | 85 | 60 | 2,480 | 220/230 | Details |
![]() |
LWAE3G250SS-7PKW-10EC | Ø250 mm | 1,916 | 201 | 115 | 68 | 2,950 | 220/230 | Details |
![]() |
LWAE3G250SS-7PNW-07EC | Ø250 mm | 1,627 | 214 | 85 | 60 | 2,480 | 220/230 | Details |
![]() |
LWAE3G250SS-7PNW-09EC | Ø250 mm | 1,916 | 1,140 | 115 | 60 | 2,950 | 220/230 | Details |
![]() |
LWAE3G250ST-7MEW-04EC | Ø250 mm | 1,751 | 290 | 135 | 69 | 3,150 | 220/230 | Details |
![]() |
LWAE3G250ST-7MGW-06EC | Ø250 mm | 1,751 | 290 | 135 | 69 | 3,150 | 220/230 | Details |
![]() |
LWAE3G250ST-7MNW-02EC | Ø250 mm | 1,751 | 290 | 135 | 69 | 3,150 | 220/230 | Details |
![]() |
LWAE3G300SS-5MEW-07EC | Ø300 mm | 1,751 | 228 | 90 | 59 | 1,600 | 220/230 | Details |
![]() |
LWAE3G300SS-5PEW-03EC | Ø300 mm | 2,575 | 168 | 242 | 64 | 2,100 | 220/230 | Details |
![]() |
LWAE3G300SS-5PEW-09EC | Ø300 mm | 2,781 | 141 | 126 | 65 | 2,100 | 230 | Details |
![]() |
LWAE3G300SS-5PEW-12EC | Ø300 mm | 1,906 | 118 | 100 | 54 | 1,600 | 220/230 | Details |
![]() |
LWAE3G300SS-5PGW-05EC | Ø300 mm | 2,575 | 168 | 165 | 64 | 2,100 | 220/230 | Details |
![]() |
LWAE3G300SS-5PGW-14EC | Ø300 mm | 1,906 | 118 | 100 | 54 | 1,600 | 220/230 | Details |
![]() |
LWAE3G300SS-5PNW-01EC | Ø300 mm | 2,575 | 168 | 165 | 64 | 2,100 | 220/230 | Details |
![]() |
LWAE3G300SS-5PNW-10EC | Ø300 mm | 1,906 | 118 | 100 | 54 | 1,600 | 220/230 | Details |
![]() |
LWAE3G300ST-5MEW-08EC | Ø300 mm | 1,751 | 228 | 90 | 59 | 1,600 | 220/230 | Details |
![]() |
LWAE3G300ST-5PEW-04EC | Ø300 mm | 2,575 | 168 | 165 | 64 | 2,100 | 220/230 | Details |
EC Axial Fans — selection guide
EC Axial Fans: 116 models, impellers Ø200–900 mm, maximum airflow 886–32,313 m³/h, static pressure to 1,140 Pa, EC motors, across 13 series. 73 of them carry a measured P-Q curve and 116 a dimensional drawing.
LWAE3G EC axial fans are the third-generation platform with a bionic blade profile and integrated EC motor: 0–10 V / PWM speed control, speed or fault feedback and high part-load efficiency, Ø200 to Ø900 mm. Sizes Ø200–450 mm run on 220 / 230 V single-phase (Ø200 alone has 20 variants), sizes Ø500–900 mm on 380 / 400 V three-phase. IP54 is standard, IP55 available, ambient −25 to +60 °C.
The EC line shares mounting dimensions with the AC line, so it is the usual upgrade for condenser pressure control, night set-back and BMS integration, with about 30% lower consumption at part load — more where the duty varies strongly, confirmed against the load profile.
How to select from this range
- Select at the maximum duty and let the controller pull speed down: an EC fan sized with 10–25% margin spends most of its life at 60–80% speed where efficiency is highest.
- Choose 0–10 V for BMS and condenser-pressure controllers, PWM for equipment controllers; both are on board.
- For redundancy in fan arrays use several smaller EC fans rather than one large one; each has its own fault output.
- Three-phase 380 / 400 V from Ø500 mm upward; single-phase 230 V below.
Where these fans are used
- Condenser pressure control on chillers and heat pumps
- Dry coolers and adiabatic coolers
- Data-center outdoor units
- Demand-controlled ventilation
Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.
FAQ — EC Axial Fans
What control signals do LWAE3G fans accept?
0–10 V and PWM speed input, with tacho or alarm output; Modbus RTU is available on request. The wiring diagram on each model page shows the terminals.
How much energy does an EC axial fan save against AC?
About 30% at part load in typical condenser duty, more where the duty varies strongly; the saving depends on the load profile, so we confirm it against your operating hours.
Which EC axial sizes are three-phase?
Ø500, 550, 630, 710, 800 and 900 mm run on 380 / 400 V three-phase; Ø200–450 mm are 220 / 230 V single-phase.