EC Axial Fans

Filter by duty point116 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAE3G300ST-5PEW-13 LWAE3G300ST-5PEW-13EC Ø300 mm 1,906 118 100 54 1,600 220/230 Details
LWAE3G300ST-5PGW-06 LWAE3G300ST-5PGW-06EC Ø300 mm 2,575 168 165 64 2,100 220/230 Details
LWAE3G300ST-5PGW-15 LWAE3G300ST-5PGW-15EC Ø300 mm 1,906 118 100 54 1,600 220/230 Details
LWAE3G300ST-5PNW-02 LWAE3G300ST-5PNW-02EC Ø300 mm 2,575 168 165 64 2,100 220/230 Details
LWAE3G300ST-5PNW-11 LWAE3G300ST-5PNW-11EC Ø300 mm 1,906 118 100 54 1,600 220/230 Details
LWAE3G315SS-5PEW-03 LWAE3G315SS-5PEW-03EC Ø315 mm 2,575 164 165 66 2,100 220/230 Details
LWAE3G315SS-5PNW-01 LWAE3G315SS-5PNW-01EC Ø315 mm 2,575 164 165 66 2,100 220/230 Details
LWAE3G315ST-5PEW-04 LWAE3G315ST-5PEW-04EC Ø315 mm 2,575 164 165 66 2,100 220/230 Details
LWAE3G315ST-5PNW-02 LWAE3G315ST-5PNW-02EC Ø315 mm 2,575 164 165 66 2,100 220/230 Details
LWAE3G350SS-5MEW-07 LWAE3G350SS-5MEW-07EC Ø350 mm 2,884 150 150 66 1,600 220/230 Details
LWAE3G350SS-5PEW-03 LWAE3G350SS-5PEW-03EC Ø350 mm 3,451 128 175 65 1,800 220/230 Details
LWAE3G350SS-5PEW-09 LWAE3G350SS-5PEW-09EC Ø350 mm 3,554 144 164 62 1,600 230 Details
LWAE3G350SS-5PGW-05 LWAE3G350SS-5PGW-05EC Ø350 mm 3,451 128 175 65 1,800 220/230 Details
LWAE3G350SS-5PNW-01 LWAE3G350SS-5PNW-01EC Ø350 mm 3,451 128 175 65 1,800 220/230 Details
LWAE3G350ST-5MEW-08 LWAE3G350ST-5MEW-08EC Ø350 mm 2,884 150 150 66 1,600 220/230 Details
LWAE3G350ST-5PEW-04 LWAE3G350ST-5PEW-04EC Ø350 mm 3,451 128 175 65 1,800 220/230 Details
LWAE3G350ST-5PGW-06 LWAE3G350ST-5PGW-06EC Ø350 mm 3,451 128 175 65 1,800 220/230 Details
LWAE3G350ST-5PNW-02 LWAE3G350ST-5PNW-02EC Ø350 mm 3,451 128 175 65 1,800 220/230 Details
LWAE3G400SS-5MEW-03 LWAE3G400SS-5MEW-03EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G400SS-5MEW-07 LWAE3G400SS-5MEW-07EC Ø400 mm 5,562 258 360 67 1,600 220/230 Details
LWAE3G400SS-5MEW-09 LWAE3G400SS-5MEW-09EC Ø400 mm 4,871 190 264 66 1,800 230 Details
LWAE3G400SS-5MGW-05 LWAE3G400SS-5MGW-05EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G400SS-5MNW-01 LWAE3G400SS-5MNW-01EC Ø400 mm 4,944 208 315 69 1,600 220 Details
LWAE3G400ST-5MEW-04 LWAE3G400ST-5MEW-04EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G400ST-5MEW-08 LWAE3G400ST-5MEW-08EC Ø400 mm 5,562 258 360 67 1,600 220/230 Details
LWAE3G400ST-5MGW-06 LWAE3G400ST-5MGW-06EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G400ST-5MNW-02 LWAE3G400ST-5MNW-02EC Ø400 mm 4,944 208 315 69 1,600 220/230 Details
LWAE3G450SS-5MEW-03 LWAE3G450SS-5MEW-03EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450SS-5MEW-07 LWAE3G450SS-5MEW-07EC Ø450 mm 6,386 232 445 68 1,600 220/230 Details
LWAE3G450SS-5MEW-09 LWAE3G450SS-5MEW-09EC Ø450 mm 5,871 163 264 67 1,670 230 Details
LWAE3G450SS-5MGW-05 LWAE3G450SS-5MGW-05EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450SS-5MNW-01 LWAE3G450SS-5MNW-01EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450SS-5PEW-10 LWAE3G450SS-5PEW-10EC Ø450 mm 4,266 80 100 52 1,080 220 Details
LWAE3G450ST-5MEW-04 LWAE3G450ST-5MEW-04EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450ST-5MEW-08 LWAE3G450ST-5MEW-08EC Ø450 mm 6,386 232 445 68 1,600 220/230 Details
LWAE3G450ST-5MGW-06 LWAE3G450ST-5MGW-06EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G450ST-5MNW-02 LWAE3G450ST-5MNW-02EC Ø450 mm 6,695 242 420 68 1,590 220/230 Details
LWAE3G500SS-5MEW-11 LWAE3G500SS-5MEW-11EC Ø500 mm 6,971 176 343 67 1,380 230 Details
LWAE3G500SS-5PKW-12 LWAE3G500SS-5PKW-12EC Ø500 mm 9,122 143 586 78 1,400 230 Details
LWAE3G500SS-5PKW-15 LWAE3G500SS-5PKW-15EC Ø500 mm 5,900 see curve 200 56 900 230 Details
Certifications for this product line
RoHS
View certificates →

EC Axial Fans — selection guide

EC Axial Fans: 116 models, impellers Ø200–900 mm, maximum airflow 886–32,313 m³/h, static pressure to 1,140 Pa, EC motors, across 13 series. 73 of them carry a measured P-Q curve and 116 a dimensional drawing.

LWAE3G EC axial fans are the third-generation platform with a bionic blade profile and integrated EC motor: 0–10 V / PWM speed control, speed or fault feedback and high part-load efficiency, Ø200 to Ø900 mm. Sizes Ø200–450 mm run on 220 / 230 V single-phase (Ø200 alone has 20 variants), sizes Ø500–900 mm on 380 / 400 V three-phase. IP54 is standard, IP55 available, ambient −25 to +60 °C.

The EC line shares mounting dimensions with the AC line, so it is the usual upgrade for condenser pressure control, night set-back and BMS integration, with about 30% lower consumption at part load — more where the duty varies strongly, confirmed against the load profile.

How to select from this range

  1. Select at the maximum duty and let the controller pull speed down: an EC fan sized with 10–25% margin spends most of its life at 60–80% speed where efficiency is highest.
  2. Choose 0–10 V for BMS and condenser-pressure controllers, PWM for equipment controllers; both are on board.
  3. For redundancy in fan arrays use several smaller EC fans rather than one large one; each has its own fault output.
  4. Three-phase 380 / 400 V from Ø500 mm upward; single-phase 230 V below.

Where these fans are used

  • Condenser pressure control on chillers and heat pumps
  • Dry coolers and adiabatic coolers
  • Data-center outdoor units
  • Demand-controlled ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — EC Axial Fans

What control signals do LWAE3G fans accept?

0–10 V and PWM speed input, with tacho or alarm output; Modbus RTU is available on request. The wiring diagram on each model page shows the terminals.

How much energy does an EC axial fan save against AC?

About 30% at part load in typical condenser duty, more where the duty varies strongly; the saving depends on the load profile, so we confirm it against your operating hours.

Which EC axial sizes are three-phase?

Ø500, 550, 630, 710, 800 and 900 mm run on 380 / 400 V three-phase; Ø200–450 mm are 220 / 230 V single-phase.