ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAA4E400S-5MKB-17 LWAA4E400S-5MKB-17AC Ø400 mm 4,429 see curve 225 58 1,380 220/230 Details
LWAA4E400S-5MKB-18 LWAA4E400S-5MKB-18AC Ø400 mm 4,069 see curve 180 68 1,400 220/230 Details
LWAA4E420S-5MEB-01 LWAA4E420S-5MEB-01AC Ø420 mm 5,459 see curve 300 65 1,350 220/230 Details
LWAA4E420S-5MEB-02 LWAA4E420S-5MEB-02AC Ø420 mm 5,974 see curve 400 68 1,580 220/230 Details
LWAA4E450B-5MKB-22 LWAA4E450B-5MKB-22AC Ø450 mm 4,635 see curve 250 62 1,350 220/230 Details
LWAA4E450S-5MEB-01 LWAA4E450S-5MEB-01AC Ø450 mm 4,635 see curve 250 62 1,350 220/230 Details
LWAA4E450S-5MEB-02 LWAA4E450S-5MEB-02AC Ø450 mm 4,944 see curve 280 64 1,600 220/230 Details
LWAA4E450S-5MEB-09 LWAA4E450S-5MEB-09AC Ø450 mm 7,004 see curve 480 66 1,350 230 Details
LWAA4E450S-5MEB-11 LWAA4E450S-5MEB-11AC Ø450 mm 5,768 see curve 380 64 1,350 220/230 Details
LWAA4E450S-5MEB-13 LWAA4E450S-5MEB-13AC Ø450 mm 7,025 see curve 400 72 1,420 230 Details
LWAA4E450S-5MEB-14 LWAA4E450S-5MEB-14AC Ø450 mm 5,150 see curve 270 58 1,350 220/230 Details
LWAA4E450S-5MEB-15 LWAA4E450S-5MEB-15AC Ø450 mm 5,665 see curve 330 60 1,400 220/230 Details
LWAA4E450S-5MEW-22 LWAA4E450S-5MEW-22AC Ø450 mm 5,562 see curve 280 1,350 220 Details
LWAA4E450S-5MKB-18 LWAA4E450S-5MKB-18AC Ø450 mm 5,459 see curve 270 58 1,350 220/230 Details
LWAA4E450S-5MKB-19 LWAA4E450S-5MKB-19AC Ø450 mm 5,665 see curve 330 60 1,400 220/230 Details
LWAA4E500B-5MKB-12 LWAA4E500B-5MKB-12AC Ø500 mm 6,850 see curve 420 69 1,320 220/230 Details
LWAA4E500S-5MEB-01 LWAA4E500S-5MEB-01AC Ø500 mm 6,695 see curve 420 69 1,320 220/230 Details
LWAA4E500S-5MEB-02 LWAA4E500S-5MEB-02AC Ø500 mm 7,004 see curve 500 70 1,450 220/230 Details
LWAA4E500S-5MEB-09 LWAA4E500S-5MEB-09AC Ø500 mm 9,270 see curve 800 80 1,320 220/230 Details
LWAA4E550B-5MKB-09 LWAA4E550B-5MKB-09AC Ø550 mm 8,034 see curve 550 73 1,320 220/230 Details
LWAA4E550S-5MEB-01 LWAA4E550S-5MEB-01AC Ø550 mm 8,034 see curve 550 73 1,320 220/230 Details
LWAA4E550S-5MEB-02 LWAA4E550S-5MEB-02AC Ø550 mm 8,755 see curve 550 74 1,450 220/230 Details
LWAA6D350S-5MEB-07 LWAA6D350S-5MEB-07AC Ø350 mm 1,607 see curve 70 53 920 380 Details
LWAA6D350S-5MEB-08 LWAA6D350S-5MEB-08AC Ø350 mm 1,854 see curve 80 54 1,050 380 Details
LWAA6D400S-5MEB-07 LWAA6D400S-5MEB-07AC Ø400 mm 2,678 see curve 100 49 930 380 Details
LWAA6D400S-5MEB-08 LWAA6D400S-5MEB-08AC Ø400 mm 3,090 see curve 120 52 1,100 380 Details
LWAA6D450S-5MEB-07 LWAA6D450S-5MEB-07AC Ø450 mm 2,987 see curve 135 56 910 380 Details
LWAA6D450S-5MEB-08 LWAA6D450S-5MEB-08AC Ø450 mm 3,502 see curve 140 58 1,030 380 Details
LWAA6D500S-5MEB-07 LWAA6D500S-5MEB-07AC Ø500 mm 4,450 see curve 220 65 900 380 Details
LWAA6D500S-5MEB-08 LWAA6D500S-5MEB-08AC Ø500 mm 4,944 see curve 250 66 1,100 380 Details
LWAA6D550S-5MEB-07 LWAA6D550S-5MEB-07AC Ø550 mm 6,695 see curve 320 62 910 380 Details
LWAA6D550S-5MEB-08 LWAA6D550S-5MEB-08AC Ø550 mm 7,210 see curve 440 66 1,090 380 Details
LWAA6D600S-5MEB-04 LWAA6D600S-5MEB-04AC Ø600 mm 9,785 see curve 500 67 920 380 Details
LWAA6D600S-5MEB-05 LWAA6D600S-5MEB-05AC Ø600 mm 10,197 see curve 650 69 1,070 380 Details
LWAA6D630B-5MKB-12 LWAA6D630B-5MKB-12AC Ø630 mm 11,021 see curve 520 67 900 380/400 Details
LWAA6D630B-5MKB-13 LWAA6D630B-5MKB-13AC Ø630 mm 12,154 see curve 740 69 1,050 380/400 Details
LWAA6D630S-4MKB-10 LWAA6D630S-4MKB-10AC Ø630 mm 10,815 see curve 450 68 925 380 Details
LWAA6D630S-5MEB-04 LWAA6D630S-5MEB-04AC Ø630 mm 11,021 see curve 520 67 900 380 Details
LWAA6D630S-5MEB-05 LWAA6D630S-5MEB-05AC Ø630 mm 10,815 see curve 740 69 1,060 380 Details
LWAA6D710S-5MEW-07 LWAA6D710S-5MEW-07AC Ø710 mm 17,510 see curve 1,200 920 380 Details
Certifications for this product line
RoHS
View certificates →

Axial Fans — selection guide

Axial Fans: 435 models, impellers Ø145–1,000 mm, maximum airflow 23–48,326 m³/h, static pressure to 3,690 Pa, AC, EC and DC motors, across 98 series. 96 of them carry a measured P-Q curve and 395 a dimensional drawing.

The axial range covers Ø145 to Ø1,000 mm in five lines that overlap in diameter but not in job. LWAA AC external-rotor fans (2-, 4-, 6- and 8-pole) are the fixed-speed workhorses for condensers and heat pumps; LWAE3G EC fans add speed control and part-load efficiency on the same mounting dimensions; LWAD3G DC fans serve 24 / 48 V and 310 V DC-bus equipment; LWWAF and LWEA industrial fans move very large volumes at low pressure in wall rings and casings; and LWMFAF / LWEAF tube axial fans handle higher pressures inside a duct.

Most models are IP54 with cold-rolled-steel or PA66 impellers, rated for −30 to +60 °C ambient (EC: −25 to +60 °C), on maintenance-free ball bearings. Three-phase 380 V and single-phase 220 / 230 V versions exist for nearly every size, and the largest EC fans (Ø500–900 mm) are three-phase.

How to select from this range

  1. Use the airflow at the coil or grille and the resistance it creates — a condenser coil and guard grille cost 30–80 Pa, which is a large share of an axial fan's pressure capability.
  2. Choose diameter for airflow and speed grade (pole count or EC speed setting) for pressure and noise; two adjacent diameters usually cover the same duty with 3–6 dB(A) difference.
  3. Stay on the falling, right-hand part of the curve. Left of the pressure peak an axial fan stalls and the noise rises sharply.
  4. For condenser pressure control, night set-back or redundancy choose EC (LWAE3G); for constant duty at lowest cost choose AC (LWAA).
  5. Match the mounting format — wall ring, guard grille, short case or long case — to the drawing before ordering; the same impeller is offered in several formats.

Where these fans are used

  • Condensers, evaporators and dry coolers
  • Heat-pump and chiller outdoor units
  • Cooling towers and transformer cooling
  • Factory and warehouse ventilation
  • Tunnel and agricultural ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Axial Fans

What static pressure can LONGWELL axial fans handle?

The LWAA / LWAE3G external-rotor fans are selected up to about 100–400 Pa depending on diameter and speed; the tube axial LWMFAF / LWEAF line reaches 750–3,690 Pa total pressure at the cost of noise. Above the external-rotor range the selector will usually offer a mixed flow or centrifugal alternative.

How do I read the LWAA model code?

LWAA4E400S-5MEW: 4 = poles, E = single-phase (D = three-phase), 400 = impeller diameter in mm, then the mounting and impeller code. So a 4-pole single-phase Ø400 mm fan. LWAE3G is the EC platform, LWAD3G the DC platform on the same numbering.

Which axial sizes are offered in EC?

LWAE3G runs from Ø200 to Ø900 mm: Ø200–450 mm on 220 / 230 V single-phase, Ø500–900 mm on 380 / 400 V three-phase, all with 0–10 V / PWM control and feedback, IP54 or IP55.

Do you have 60 Hz or 115 V axial fans?

The AC line is built for 50 Hz 230 / 380 V as standard and many sizes are available for 60 Hz; the industrial LWEA line is offered in 110–120 V. EC fans accept 50 / 60 Hz on the same model. Filter the category by voltage or ask for the variant you need.

Related selections

Scroll to Top
RFQ list