Cooling Fans & Blowers

Filter by duty point879 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAD8010MD-05 LWAD8010MD-05DC 80 mm 39.6 10 1.44 24.9 2,000 24 Details
LWAD8010MH-02 LWAD8010MH-02DC 80 mm 69.6 32 2.4 37.1 3,500 24 Details
LWAD8010ML-04 LWAD8010ML-04DC 80 mm 49.8 16 1.68 29.8 2,500 24 Details
LWAD8010MM-03 LWAD8010MM-03DC 80 mm 59.4 23 2.16 33.8 3,000 24 Details
LWAD8010MX-01 LWAD8010MX-01DC 80 mm 79.2 41 2.88 40 4,000 24 Details
LWAD8015KD-05 LWAD8015KD-05DC 80 mm 29.4 7 1 17.7 1,500 5 Details
LWAD8015KH-02 LWAD8015KH-02DC 80 mm 59.4 27 2.5 32.8 3,000 5 Details
LWAD8015KL-04 LWAD8015KL-04DC 80 mm 39.6 12 1.5 23.9 2,000 5 Details
LWAD8015KM-03 LWAD8015KM-03DC 80 mm 49.2 18 2 28.8 2,500 5 Details
LWAD8015KX-01 LWAD8015KX-01DC 80 mm 69 36 3.25 36.1 3,500 5 Details
LWAD8015LD-05 LWAD8015LD-05DC 80 mm 29.4 7 1.2 17.7 1,500 12 Details
LWAD8015LH-02 LWAD8015LH-02DC 80 mm 59.4 27 3 32.8 3,000 12 Details
LWAD8015LL-04 LWAD8015LL-04DC 80 mm 39.6 12 1.8 23.9 2,000 12 Details
LWAD8015LM-03 LWAD8015LM-03DC 80 mm 49.2 18 2.4 28.8 2,500 12 Details
LWAD8015LX-01 LWAD8015LX-01DC 80 mm 69 36 3.6 36.1 3,500 12 Details
LWAD8015MD-05 LWAD8015MD-05DC 80 mm 29.4 7 1.44 17.7 1,500 24 Details
LWAD8015MH-02 LWAD8015MH-02DC 80 mm 59.4 27 3.12 32.8 3,000 24 Details
LWAD8015ML-04 LWAD8015ML-04DC 80 mm 39.6 12 1.92 23.9 2,000 24 Details
LWAD8015MM-03 LWAD8015MM-03DC 80 mm 49.2 18 2.4 28.8 2,500 24 Details
LWAD8015MX-01 LWAD8015MX-01DC 80 mm 69 36 3.6 36.1 3,500 24 Details
LWAD8020HD-05 LWAD8020HD-05DC 80 mm 40.2 19 3.84 30.6 2,500 48 Details
LWAD8020HH-02 LWAD8020HH-02DC 80 mm 64.2 49 7.2 40.8 4,000 48 Details
LWAD8020HL-04 LWAD8020HL-04DC 80 mm 48 27 4.8 34.6 3,000 48 Details
LWAD8020HM-03 LWAD8020HM-03DC 80 mm 56.4 37 6.24 37.9 3,500 48 Details
LWAD8020HX-01 LWAD8020HX-01DC 80 mm 72.6 62 8.64 43.4 4,500 48 Details
LWAD8020LD-05 LWAD8020LD-05DC 80 mm 40.2 19 1.8 30.6 2,500 12 Details
LWAD8020LH-02 LWAD8020LH-02DC 80 mm 64.2 49 3.6 40.8 4,000 12 Details
LWAD8020LL-04 LWAD8020LL-04DC 80 mm 48 27 2.4 34.6 3,000 12 Details
LWAD8020LM-03 LWAD8020LM-03DC 80 mm 56.4 37 3 37.9 3,500 12 Details
LWAD8020LX-01 LWAD8020LX-01DC 80 mm 72.6 62 4.2 43.4 4,500 12 Details
LWAD8020MD-05 LWAD8020MD-05DC 80 mm 40.2 19 2.4 30.6 2,500 24 Details
LWAD8020MH-02 LWAD8020MH-02DC 80 mm 64.2 49 5.28 40.8 4,000 24 Details
LWAD8020ML-04 LWAD8020ML-04DC 80 mm 48 27 3.6 34.6 3,000 24 Details
LWAD8020MM-03 LWAD8020MM-03DC 80 mm 56.4 37 4.08 37.9 3,500 24 Details
LWAD8020MX-01 LWAD8020MX-01DC 80 mm 72.6 62 6 43.4 4,500 24 Details
LWAD8025HD-09 LWAD8025HD-09DC 80 mm 60 23 7.2 30.5 2,500 48 Details
LWAD8025HD-14 LWAD8025HD-14DC 80 mm 115.2 113 7.2 51.6 6,000 48 Details
LWAD8025HD-19 LWAD8025HD-19DC 80 mm 76.2 41 7.2 39.5 3,000 48 Details
LWAD8025HH-06 LWAD8025HH-06DC 80 mm 96 58 19.2 40.7 4,000 48 Details
LWAD8025HH-11 LWAD8025HH-11DC 80 mm 173.4 254 19.2 60.4 9,000 48 Details

Cooling Fans & Blowers — selection guide

Cooling Fans & Blowers: 879 models, frame sizes 24–254 mm, maximum airflow 2–4,800 m³/h, static pressure to 2,650 Pa, DC, AC and EC motors, across 54 series. 157 of them carry a measured P-Q curve and 864 a dimensional drawing.

This is the compact end of the catalogue: 879 models for cooling electronics, cabinets and equipment. DC axial fans (LWAD) run from 25 × 25 mm to 200 mm frame with thicknesses from 10 to 60 mm, DC centrifugal blowers (LWFD) from Ø40 to Ø120 mm for pushing air through heatsinks and ducts, EC cooling fans (LWAE) from 60 to 254 mm on a 100–240 V universal AC input, and AC air blowers (LWB / LWT) for blow-off and air-knife duties up to 2,650 Pa.

Frames are UL94 V-0 plastic, supply voltages 5 / 12 / 24 / 48 V DC, and the model code carries frame, thickness and speed grade — LWAD8025HL is an 80 × 25 mm fan in the H-speed L-variant. Ball-bearing versions are the standard for continuous duty.

How to select from this range

  1. Estimate airflow from the heat load: Q (m³/h) ≈ 3 × P (W) / ΔT (K), then add the resistance of filters, grilles and heatsinks.
  2. Take the largest frame that fits — a bigger fan at lower speed gives the same airflow at far lower noise and longer life.
  3. Use a DC blower (LWFD) where air must be forced through a narrow channel or dense heatsink; an axial fan where the enclosure is open.
  4. Specify the control interface at the outset: PWM, tacho (FG), alarm (RD) or 0–10 V; it is part of the model code.
  5. Check life at the real ambient: ball-bearing L10 ratings are given at 40 °C and halve for roughly every 10 K above.

Where these fans are used

  • Power supplies, UPS and inverters
  • Telecom and server cabinets
  • EV chargers and battery packs
  • Medical and laboratory devices
  • Displays, projectors and appliances

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cooling Fans & Blowers

How do I decode a cooling fan model such as LWAD8025HL?

LWAD = DC axial cooling fan (LWFD = DC blower, LWAE = EC), 80 = frame in mm, 25 = thickness in mm, H = speed grade (H / M / L), L = variant. Within one frame the speed grades trade airflow against noise; the technical data lists each.

Which frame sizes are in stock as standard?

40, 50, 60, 70, 80, 92 and 120 mm frames carry the most variants (up to 15 per series), which is where samples ship fastest. 25, 30, 172 and 200 mm are also catalogued.

Can you supply PWM control and tacho output?

Yes. Most DC frames are available with PWM speed input, FG tacho signal and RD alarm output; EC models add 0–10 V control. Tell us the required signal when you request the sample.

Do the cooling fans have UL / CE documentation?

Frames are UL94 V-0, CE / RoHS declarations are available per model, and the DC centrifugal blower line is ETL listed (Intertek control no. 5022563).

Related selections

Scroll to Top
RFQ list