Cooling Fans & Blowers

Filter by duty point879 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWAD6038LD-05 LWAD6038LD-05DC 60 mm 51 84 3.6 45.5 5,500 12 Details
LWAD6038LH-02 LWAD6038LH-02DC 60 mm 79.2 200 9.6 54.9 8,500 12 Details
LWAD6038LL-04 LWAD6038LL-04DC 60 mm 60.6 117 4.8 49.1 6,500 12 Details
LWAD6038LM-03 LWAD6038LM-03DC 60 mm 70.2 155 7.2 52.2 7,500 12 Details
LWAD6038LX-01 LWAD6038LX-01DC 60 mm 88.8 249 12 57.3 9,500 12 Details
LWAD6038MD-05 LWAD6038MD-05DC 60 mm 51 84 4.8 45.5 5,500 24 Details
LWAD6038MH-02 LWAD6038MH-02DC 60 mm 79.2 200 12 54.9 8,500 24 Details
LWAD6038ML-04 LWAD6038ML-04DC 60 mm 60.6 117 6 49.1 6,500 24 Details
LWAD6038MM-03 LWAD6038MM-03DC 60 mm 70.2 155 9.6 52.2 7,500 24 Details
LWAD6038MX-01 LWAD6038MX-01DC 60 mm 88.8 249 16.8 57.3 9,500 24 Details
LWAD7010KD-05 LWAD7010KD-05DC 70 mm 36.6 15 0.75 29.4 3,000 5 Details
LWAD7010KH-02 LWAD7010KH-02DC 70 mm 55.2 35 2 38.2 4,500 5 Details
LWAD7010KL-04 LWAD7010KL-04DC 70 mm 42.6 21 1.25 32.8 3,500 5 Details
LWAD7010KM-03 LWAD7010KM-03DC 70 mm 48.6 27 1.75 35.7 4,000 5 Details
LWAD7010KX-01 LWAD7010KX-01DC 70 mm 61.2 43 2.25 40.5 5,000 5 Details
LWAD7010LD-05 LWAD7010LD-05DC 70 mm 36.6 15 0.72 29.4 3,000 12 Details
LWAD7010LH-02 LWAD7010LH-02DC 70 mm 55.2 35 2.16 38.2 4,500 12 Details
LWAD7010LL-04 LWAD7010LL-04DC 70 mm 42.6 21 1.2 32.8 3,500 12 Details
LWAD7010LM-03 LWAD7010LM-03DC 70 mm 48.6 27 1.92 35.7 4,000 12 Details
LWAD7010LX-01 LWAD7010LX-01DC 70 mm 61.2 43 2.4 40.5 5,000 12 Details
LWAD7010MD-05 LWAD7010MD-05DC 70 mm 36.6 15 1.44 29.4 3,000 24 Details
LWAD7010MH-02 LWAD7010MH-02DC 70 mm 55.2 35 2.4 38.2 4,500 24 Details
LWAD7010ML-04 LWAD7010ML-04DC 70 mm 42.6 21 1.68 32.8 3,500 24 Details
LWAD7010MM-03 LWAD7010MM-03DC 70 mm 48.6 27 2.16 35.7 4,000 24 Details
LWAD7010MX-01 LWAD7010MX-01DC 70 mm 61.2 43 2.88 40.5 5,000 24 Details
LWAD7015KD-05 LWAD7015KD-05DC 70 mm 31.2 14 1.5 23 2,500 5 Details
LWAD7015KH-02 LWAD7015KH-02DC 70 mm 49.8 36 2.5 33.2 4,000 5 Details
LWAD7015KL-04 LWAD7015KL-04DC 70 mm 37.2 20 2 27 3,000 5 Details
LWAD7015KM-03 LWAD7015KM-03DC 70 mm 43.2 28 2.25 30.3 3,500 5 Details
LWAD7015KX-01 LWAD7015KX-01DC 70 mm 55.8 46 3 35.8 4,500 5 Details
LWAD7015LD-05 LWAD7015LD-05DC 70 mm 31.2 14 1.8 23 2,500 12 Details
LWAD7015LH-02 LWAD7015LH-02DC 70 mm 49.8 36 3.12 33.2 4,000 12 Details
LWAD7015LL-04 LWAD7015LL-04DC 70 mm 37.2 20 2.4 27 3,000 12 Details
LWAD7015LM-03 LWAD7015LM-03DC 70 mm 43.2 28 2.64 30.3 3,500 12 Details
LWAD7015LX-01 LWAD7015LX-01DC 70 mm 55.8 46 3.6 35.8 4,500 12 Details
LWAD7015MD-05 LWAD7015MD-05DC 70 mm 31.2 14 2.4 23 2,500 24 Details
LWAD7015MH-02 LWAD7015MH-02DC 70 mm 49.8 36 3.84 33.2 4,000 24 Details
LWAD7015ML-04 LWAD7015ML-04DC 70 mm 37.2 20 2.88 27 3,000 24 Details
LWAD7015MM-03 LWAD7015MM-03DC 70 mm 43.2 28 3.36 30.3 3,500 24 Details
LWAD7015MX-01 LWAD7015MX-01DC 70 mm 55.8 46 4.8 35.8 4,500 24 Details

Cooling Fans & Blowers — selection guide

Cooling Fans & Blowers: 879 models, frame sizes 24–254 mm, maximum airflow 2–4,800 m³/h, static pressure to 2,650 Pa, DC, AC and EC motors, across 54 series. 157 of them carry a measured P-Q curve and 864 a dimensional drawing.

This is the compact end of the catalogue: 879 models for cooling electronics, cabinets and equipment. DC axial fans (LWAD) run from 25 × 25 mm to 200 mm frame with thicknesses from 10 to 60 mm, DC centrifugal blowers (LWFD) from Ø40 to Ø120 mm for pushing air through heatsinks and ducts, EC cooling fans (LWAE) from 60 to 254 mm on a 100–240 V universal AC input, and AC air blowers (LWB / LWT) for blow-off and air-knife duties up to 2,650 Pa.

Frames are UL94 V-0 plastic, supply voltages 5 / 12 / 24 / 48 V DC, and the model code carries frame, thickness and speed grade — LWAD8025HL is an 80 × 25 mm fan in the H-speed L-variant. Ball-bearing versions are the standard for continuous duty.

How to select from this range

  1. Estimate airflow from the heat load: Q (m³/h) ≈ 3 × P (W) / ΔT (K), then add the resistance of filters, grilles and heatsinks.
  2. Take the largest frame that fits — a bigger fan at lower speed gives the same airflow at far lower noise and longer life.
  3. Use a DC blower (LWFD) where air must be forced through a narrow channel or dense heatsink; an axial fan where the enclosure is open.
  4. Specify the control interface at the outset: PWM, tacho (FG), alarm (RD) or 0–10 V; it is part of the model code.
  5. Check life at the real ambient: ball-bearing L10 ratings are given at 40 °C and halve for roughly every 10 K above.

Where these fans are used

  • Power supplies, UPS and inverters
  • Telecom and server cabinets
  • EV chargers and battery packs
  • Medical and laboratory devices
  • Displays, projectors and appliances

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cooling Fans & Blowers

How do I decode a cooling fan model such as LWAD8025HL?

LWAD = DC axial cooling fan (LWFD = DC blower, LWAE = EC), 80 = frame in mm, 25 = thickness in mm, H = speed grade (H / M / L), L = variant. Within one frame the speed grades trade airflow against noise; the technical data lists each.

Which frame sizes are in stock as standard?

40, 50, 60, 70, 80, 92 and 120 mm frames carry the most variants (up to 15 per series), which is where samples ship fastest. 25, 30, 172 and 200 mm are also catalogued.

Can you supply PWM control and tacho output?

Yes. Most DC frames are available with PWM speed input, FG tacho signal and RD alarm output; EC models add 0–10 V control. Tell us the required signal when you request the sample.

Do the cooling fans have UL / CE documentation?

Frames are UL94 V-0, CE / RoHS declarations are available per model, and the DC centrifugal blower line is ETL listed (Intertek control no. 5022563).

Related selections

Scroll to Top
RFQ list