Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.
- ImpellerØ250 mm9.8 in
- Max airflow1,421 m³/h836 CFM
- Max static pressure618 Pa2.48 in. wg
- Voltage380 V
- Speed2,450 rpm
- Input power150 W
- Noise76 dB(A)
LWBA2D250-092NT-15 AC Backward Curved Centrifugal Fan Ø250 mm
Ø250 mm | AC | Max airflow 1,421 m³/h | Max static pressure 618 Pa | 76 dB(A)
- Factory direct
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 18-month warranty
- CE · ETL · RoHS



Need a non-standard size or another format? Ask an engineer or search the download center.
LWBA2D250-092NT-15 is a LONGWELL AC Backward Curved Centrifugal Fan from the Backward Curved Centrifugal Fans range, impeller Ø250 mm, rated 380 V AC, maximum airflow 1,421 m³/h, maximum static pressure 618 Pa, noise 76 dB(A), input power 150 W. The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.
Technical data
| Model | LWBA2D250-092NT-15 |
|---|---|
| Series | LWBA2D250 |
| Motor type | AC |
| Phase | 3-phase |
| Rated voltage | 380 V |
| Frequency | 50 Hz |
| Current | 0.31 A |
| Input power | 150 W |
| Speed | 2,450 rpm |
| Max. airflow | 1,421 m³/h |
| Max. static pressure | 618 Pa |
| Noise | 76 dB(A) |
| Ambient temperature | -40 ~ 65 °C |
| Storage temperature | -10 ~ 40℃ |
| Humidity | 0 ~ 95 % RH |
| Altitude | < 1000m |
| Impeller diameter | Ø250 mm |
| Rotor diameter | 92 |
| Impeller material | Galvanised sheet steel |
| Protection class | IP44 |
| Insulation class | F |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
| Vibration standard | JB/T 8689 |
| Service life | 30,000Hours(L10), At 40 °Croom, humidity 15%~65%RH. Balancing According to JB/T 9101-1999 requirements G6.3 Vibration of the fan Test method accord with JB/T 8689 Installation method Horizontal or vertical installation Mate |
| Rotation | Clockwise,seen on rotor |
Typical applications
- Air handling units (AHU) and rooftop units (RTU)
- Data-center CRAH / CRAC units and fan walls
- Dust extraction and process ventilation
- Fan filter units and air purifiers
Series LWBA2D250: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Alternatives with the same impeller (Ø250 mm · AC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWBA2D250-092NT-15 this model | 1,421 m³/h | 618 Pa | 2,450 rpm | 150 W | 76 dB(A) | 380 V | |
| LWA-250(10")U(S)M-01 | 28 m³/h | see curve | 1,350 rpm | 80 W | — | 110-120 V | View |
| LWA-250(10")U(S)M-02 | 48 m³/h | see curve | 2,800 rpm | 230 W | — | 110-120 V | View |
| LWDA-250S-MBN-10 | 1,034 m³/h | 515 Pa | 2,615 rpm | 165 W | 71 dB(A) | 230 V | View |
| LWDA-250 (10")U-MWN-01 | 1,219 m³/h | see curve | 3,000 rpm | 228 W | 69 dB(A) | 110-120 V | View |
| LWDA-250 (10")U-MWN-03 | 1,219 m³/h | see curve | 3,000 rpm | 228 W | 62 dB(A) | 110-120 V | View |
| LWDA-250(8'')S-PWN-05 | 1,600 m³/h | 420 Pa | 2,500 rpm | 175 W | 50 dB(A) | 230 V | View |
| LWFA6E250-102NS-04 | 1,751 m³/h | 164.8 Pa | 900 rpm | 320 W | 62 dB(A) | 220 V | View |
| LWFA6D250-102NT-03 | 1,751 m³/h | 164.8 Pa | 910 rpm | 320 W | 62 dB(A) | 380 V | View |
| LWDA-250 (10")S-MWN-02 | 1,900 m³/h | see curve | 2,750 rpm | 162 W | 68 dB(A) | 220-240 V | View |
| LWDA-250 (10")S-MWN-04 | 1,900 m³/h | see curve | 2,750 rpm | 162 W | 60 dB(A) | 220-240 V | View |
| LWFA-E-250-02 | 2,100 m³/h | 215 Pa | — | — | 64 dB(A) | — | View |
| LWA-250(10")U(S)M-03 | 2,100 m³/h | 215 Pa | 2,800 rpm | 250 W | — | 110-120 V | View |
| LWDA-250(10")S-MWN-06 | 2,100 m³/h | 215 Pa | 2,800 rpm | 100 W | 65 dB(A) | 220 V | View |
| LWFA-E-250-01 | 2,500 m³/h | 380 Pa | — | — | 70 dB(A) | — | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWBA2D250 seriesSame impeller, different speed grade or wiring
Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWBE3G270-092NS-02Ø270 mm · 1,545 m³/h · 332 Pa · ECadjacent size
LWBE3G270-092NU-01Ø270 mm · 1,545 m³/h · 332 Pa · ECadjacent size
LWBA2E225-092NS-01Ø225 mm · 618 m³/h · 165 Pa · ACadjacent size
LWFA4D225-138ST-02Ø225 mm · 1,442 m³/h · 288.4 Pa · ACadjacent size
LWBA4E225-092NS-02Ø225 mm · 690 m³/h · 216 Pa · ACadjacent size
LWFA4D225-138NT-01Ø225 mm · 1,648 m³/h · 288.4 Pa · ACadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWBA2E250-092NS-13Ø250 mm · 1,421 m³/h · 618 Pa · ACsimilar duty
LWBE3G250-072NS-21Ø250 mm · 1,421 m³/h · 639 Pa · ECsimilar duty
LWBE3G250-092NS-23Ø250 mm · 1,421 m³/h · 556 Pa · ECsimilar duty
LWBE3G250-072PS-17Ø250 mm · 1,421 m³/h · 639 Pa · ECsimilar duty
LWBE3G250-092PS-21Ø250 mm · 1,421 m³/h · 556 Pa · ECsimilar duty
LWCD-110620MN-06Ø110 mm · 1,437 m³/h · 244 Pa · DCsimilar dutySee all Backward Curved Centrifugal Fans · select by duty point