Representative image of the series — dimensions and configuration of this model are given in the drawing and data table below.
- ImpellerØ180 mm7.1 in
- Max airflow742 m³/h437 CFM
- Max static pressure670 Pa2.69 in. wg
- Voltage230 V
- Speed2,000 rpm
- Input power300 W
- Noise73 dB(A)
LWFA2E180-092SS-03 AC Single Inlet Forward Centrifugal Blower Ø180 mm
Ø180 mm | AC | Max airflow 742 m³/h | Max static pressure 670 Pa | 73 dB(A)
- Direct from LONGWELL
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 12-month warranty
- CE · RoHS · ETL on request
CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center
Performance curve (P-Q) LWFA2E180-092SS-03
Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade (1 here, rated 230 V). Data version: catalogue curve re-digitised 2026-09-20 (axis-calibrated, cross-checked). The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.
Drawing, Curve & Wiring LWFA2E180-092SS-03



Files for LWFA2E180-092SS-03: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.
Technical description LWFA2E180-092SS-03
LWFA2E180-092SS-03 is a LONGWELL AC Single Inlet Forward Centrifugal Blower from the Single Inlet Forward Curved Blowers range, impeller Ø180 mm, rated 230 V AC, maximum airflow 742 m³/h, maximum static pressure 670 Pa, noise 73 dB(A), input power 300 W. The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.
Technical data
| Model | LWFA2E180-092SS-03 |
|---|---|
| Series | LWFA2E180 |
| Motor type | AC |
| Phase | 1-phase |
| Rated voltage | 230 V |
| Frequency | 50 Hz |
| Current | 1.35 A |
| Input power | 300 W |
| Speed | 2,000 rpm |
| Max. airflow | 742 m³/h |
| Max. static pressure | 670 Pa |
| Noise | 73 dB(A) |
| Ambient temperature | -30 ~ 60 °C |
| Storage temperature | -40 ~ 80℃ |
| Humidity | 0 ~ 95 % RH |
| Altitude | < 1000m |
| Impeller diameter | Ø180 mm |
| Rotor diameter | 92 mm |
| Impeller material | Galvanised sheet steel ( Impeller ) |
| Protection class | IP54 |
| Insulation class | F |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
| Balance grade | G6.3 |
| Vibration standard | JB/T 8689 |
| Service life | 30,000Hours(L10), At 40 °Croom, humidity 15%~65%RH |
Typical applications
- Air handling units (AHU) and rooftop units (RTU)
- Data-center CRAH / CRAC units and fan walls
- Dust extraction and process ventilation
- Fan filter units and air purifiers
Series LWFA2E180: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Company certificates
Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.
ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).
PDFISO 9001 / 14001 / 45001 management system certificateNeed a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.
How to order LWFA2E180-092SS-03
Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.
- 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
- 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
- 3SamplesStock models ship in 1–3 days.
- 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
- 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
- 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
- 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
- 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.
Test & release at LONGWELL
Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.
See test and release photos (8)








Alternatives with the same impeller (Ø180 mm · AC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWFA2E180-092SS-03 this model | 742 m³/h | 670 Pa | 2,000 rpm | 300 W | 73 dB(A) | 230 V | |
| LWBA2E180-092NS-03 | 443 m³/h | 335 Pa | 2,560 rpm | 52 W | 63 dB(A) | 230 V | View |
| LWBA2E180-092NS-01 | 443 m³/h | 335 Pa | 2,550 rpm | 52 W | 63 dB(A) | 230 V | View |
| LWBA2E180-092NS-02 | 494 m³/h | 371 Pa | 2,850 rpm | 66 W | 66 dB(A) | 230 V | View |
| LWFA4E180-092SS-02 | 772.5 m³/h | 200.85 Pa | 1,330 rpm | 135 W | 63 dB(A) | 230 V | View |
| LWFA4E180-092NS-01 | 773 m³/h | 195.7 Pa | 1,450 rpm | 85 W | 69 dB(A) | 230 V | View |
| LWFA4E180-092SS-01 | 787.5 m³/h | 315 Pa | 1,335 rpm | 137 W | 63 dB(A) | 230 V | View |
| LWFA4E180-092DS-01 | 1,205.1 m³/h | 247.2 Pa | 1,250 rpm | 200 W | 63 dB(A) | 230 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWBD3G175-072NH-03Ø175 mm · 618 m³/h · 515 Pa · DCadjacent size
LWBE3G175-072NU-17Ø175 mm · 741.6 m³/h · 535.6 Pa · ECadjacent size
LWBE3G175-072NU-18Ø175 mm · 700.4 m³/h · 803.4 Pa · ECadjacent size
LWBE3G175-072NS-06Ø175 mm · 535.6 m³/h · 453.2 Pa · ECadjacent size
LWBD3G175-072NM-02Ø175 mm · 618 m³/h · 515 Pa · DCadjacent size
LWBE3G175-072PS-10Ø175 mm · 924 m³/h · 893 Pa · ECadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
See all Centrifugal Fans · select by duty point
Go deeper on longwellfans.com
Application guides, project stories and engineering calculators for centrifugal fans — on our main site.
Solutions
- Commercial HVACAHU, rooftop, fan coil, air curtain
- FanGridsN+1 fan arrays for AHU retrofit
- Data center coolingCRAH, FanGrid, server rooms