Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.
- ImpellerØ280 mm11.0 in
- Max airflow4,422 m³/h2,601 CFM
- Max static pressure592 Pa2.38 in. wg
- Voltage230 V
- Speed820 rpm
- Input power750 W1.01 hp
- Noise74 dB(A)
LWFE3G280-138DS-02 EC Dual Inlet Forward Centrifugal Blower Ø280 mm
Ø280 mm | EC | Max airflow 4,422 m³/h | Max static pressure 592 Pa | 74 dB(A)
- Factory direct
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 18-month warranty
- CE · ETL · RoHS



Need a non-standard size or another format? Ask an engineer or search the download center.
LWFE3G280-138DS-02 is a LONGWELL EC Dual Inlet Forward Centrifugal Blower from the Dual Inlet Forward Curved Blowers range, impeller Ø280 mm, rated 230 V EC, maximum airflow 4,422 m³/h, maximum static pressure 592 Pa, noise 74 dB(A), input power 750 W. The EC motor integrates the drive electronics: stepless speed control by 0–10 V or PWM signal, speed feedback and high efficiency at part load.
Technical data
| Model | LWFE3G280-138DS-02 |
|---|---|
| Series | LWFE3G280 |
| Motor type | EC |
| Phase | 1-phase |
| Rated voltage | 230 V |
| Frequency | 50 Hz |
| Current | 3.5 A |
| Input power | 750 W |
| Speed | 820 rpm |
| Max. airflow | 4,422 m³/h |
| Max. airflow (CFM) | 2,601 CFM |
| Max. static pressure | 592 Pa |
| Noise | 74 dB(A) |
| Ambient temperature | -25 ~ 60 °C |
| Storage temperature | -40 ~ 80℃ |
| Humidity | 30 ~ 95 % RH |
| Altitude | < 1000m |
| Impeller diameter | Ø280 mm |
| Rotor diameter | 138 |
| Impeller material | Galvanised sheet steel( Impeller ) |
| Protection class | IP54 |
| Insulation class | F |
| Bearing | Maintenance-free deep groove ball bearings |
| Duty | S1 |
| Balance grade | G6.3 |
| Vibration standard | JB/T 8689 |
| Service life | 40,000Hours(L10), At 40 °Croom, humidity 15%~65%RH |
| Speed control | Control input 0~10VDC / PWM/(RS485 external control box can be connected) |
| Control signal | Control signal VSP voltage range1±0.1VDC~9.5±0.2VDC(During normal operation, when the VSP voltage is below 1.0±0.1VDC, the motor switches from operating mode to standby mode) |
| PWM input | PWM signal: frequency 1K–10KHz, amplitude 10–12V,duty cycle 30%–70% . |
| Speed feedback | Tach output: 12 Pulse/R; FG internal open circuit output, external pull-up resistor 10KΩ, pull-up voltage +10V |
| Auxiliary output | Output 10VDC, Max Current 10 mA |
| Protection functions | Over-temperature protection, Over-current protection, Locked-rotor protection’ |
| Soft start | Delay time <30 seconds to full speed |
Typical applications
- Air handling units (AHU) and rooftop units (RTU)
- Data-center CRAH / CRAC units and fan walls
- Dust extraction and process ventilation
- Fan filter units and air purifiers
Series LWFE3G280: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Alternatives with the same impeller (Ø280 mm · EC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWFE3G280-138DS-02 this model | 4,422 m³/h | 592 Pa | 820 rpm | 750 W | 74 dB(A) | 230 V | |
| LWBE3G280-092PS-14 | 1,743 m³/h | 481 Pa | 2,200 rpm | 105 W | 69 dB(A) | 230 V | View |
| LWBE3G280-092PS-15 | 1,813 m³/h | 680 Pa | 2,600 rpm | 165 W | 74 dB(A) | 230 V | View |
| LWFE3G280-092PS-03 | 2,008.5 m³/h | 803.4 Pa | 2,650 rpm | 225 W | 70 dB(A) | 230 V | View |
| LWBE3G280-092PS-13 | 2,019 m³/h | 546 Pa | 2,200 rpm | 180 W | 72 dB(A) | 230 V | View |
| LWFE3G280-072PS-01 | 2,317.5 m³/h | 556.2 Pa | 1,910 rpm | 170 W | 73 dB(A) | 230 V | View |
| LWBE3G280-102PS-16 | 2,318 m³/h | 824 Pa | 2,760 rpm | 340 W | 78 dB(A) | 230 V | View |
| LWBE3G280-102PS-18 | 2,472 m³/h | 1,051 Pa | 3,100 rpm | 475 W | 82 dB(A) | 230 V | View |
| LWBE3G280-138PT-05 | 3,028 m³/h | 886 Pa | 3,000 rpm | 860 W | 85 dB(A) | 400 V | View |
| LWBE3G280-102PS-19 | 3,039 m³/h | 1,102 Pa | 3,000 rpm | 625 W | 82 dB(A) | 230 V | View |
| LWFE3G280-102PS-07 | 3,193 m³/h | 1,442 Pa | 3,000 rpm | 500 W | 75 dB(A) | 230 V | View |
| LWBE3G280-138PT-06 | 3,790 m³/h | 1,421 Pa | 3,500 rpm | 1,355 W | 89 dB(A) | 400 V | View |
| LWBE3G280-138NT-18 | 3,790 m³/h | 1,421 Pa | 3,500 rpm | 1,355 W | 89 dB(A) | 400 V | View |
| LWFE3G280-102PS-04 | 3,862.5 m³/h | 1,658 Pa | 3,270 rpm | 700 W | 85 dB(A) | 230 V | View |
| LWFE3G280-102PT-08 | 4,377.5 m³/h | 1,751 Pa | 3,370 rpm | 1,100 W | 78 dB(A) | 400 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWFE3G280 seriesSame impeller, different speed grade or wiring
LWFE3G280-138DS-01Ø280 mm · 4,223 m³/h · 917 Pa · ECsame series
LWFE3G280-072PS-01Ø280 mm · 2,317.5 m³/h · 556.2 Pa · ECsame series
LWFE3G280-092PS-03Ø280 mm · 2,008.5 m³/h · 803.4 Pa · ECsame series
LWFE3G280-102PS-04Ø280 mm · 3,862.5 m³/h · 1,658 Pa · ECsame series
LWFE3G280-102PS-07Ø280 mm · 3,193 m³/h · 1,442 Pa · ECsame series
LWFE3G280-102PT-08Ø280 mm · 4,377.5 m³/h · 1,751 Pa · ECsame seriesAdjacent sizesOne size up when airflow is short, one size down when it is too much
LWBE3G270-092NU-01Ø270 mm · 1,545 m³/h · 332 Pa · ECadjacent size
LWBE3G270-092NS-02Ø270 mm · 1,545 m³/h · 332 Pa · ECadjacent size
LWFA6E300-138DS-01Ø300 mm · 1,596 m³/h · 368 Pa · ACadjacent size
LWFE3G310-092PS-08Ø310 mm · 2,523.5 m³/h · 669.5 Pa · ECadjacent size
LWBA2E250-092NS-14Ø250 mm · 1,499 m³/h · 773 Pa · ACadjacent size
LWBA2E250-092NS-13Ø250 mm · 1,421 m³/h · 618 Pa · ACadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
LWAA4D400S-5MKB-19Ø400 mm · 4,429 m³/h · ACsimilar duty
LWAA4E400S-5MEB-13Ø400 mm · 4,429 m³/h · ACsimilar duty
LWAA4E400S-5MEB-15Ø400 mm · 4,429 m³/h · ACsimilar duty
LWAA4E400S-5MKB-17Ø400 mm · 4,429 m³/h · ACsimilar duty
LWAA4D400S-5MEB-15Ø400 mm · 4,429 m³/h · ACsimilar duty
LWFA4E315-188NS-02Ø315 mm · 4,429 m³/h · 618 Pa · ACsimilar dutySee all Centrifugal Fans · select by duty point









