EC Axial Fans

EC axial fans integrate an electronically commutated motor and drive: stepless 0–10 V / PWM speed control, speed feedback and high part-load efficiency, ready for BMS / SCADA integration. Ø200–900 mm. Final selection is confirmed at the duty point (airflow / static pressure / voltage / control mode) and by project verification.

Filter by duty point116 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

Certifications for this product line
RoHS
View certificates →

EC Axial Fans — selection guide

EC Axial Fans: 116 models, impellers Ø200–900 mm, maximum airflow 886–32,313 m³/h, static pressure to 1,140 Pa, EC motors, across 13 series. 73 of them carry a measured P-Q curve and 116 a dimensional drawing.

LWAE3G EC axial fans are the third-generation platform with a bionic blade profile and integrated EC motor: 0–10 V / PWM speed control, speed or fault feedback and high part-load efficiency, Ø200 to Ø900 mm. Sizes Ø200–450 mm run on 220 / 230 V single-phase (Ø200 alone has 20 variants), sizes Ø500–900 mm on 380 / 400 V three-phase. IP54 is standard, IP55 available, ambient −25 to +60 °C.

The EC line shares mounting dimensions with the AC line, so it is the usual upgrade for condenser pressure control, night set-back and BMS integration, with about 30% lower consumption at part load — more where the duty varies strongly, confirmed against the load profile.

How to select from this range

  1. Select at the maximum duty and let the controller pull speed down: an EC fan sized with 10–25% margin spends most of its life at 60–80% speed where efficiency is highest.
  2. Choose 0–10 V for BMS and condenser-pressure controllers, PWM for equipment controllers; both are on board.
  3. For redundancy in fan arrays use several smaller EC fans rather than one large one; each has its own fault output.
  4. Three-phase 380 / 400 V from Ø500 mm upward; single-phase 230 V below.

Where these fans are used

  • Condenser pressure control on chillers and heat pumps
  • Dry coolers and adiabatic coolers
  • Data-center outdoor units
  • Demand-controlled ventilation

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — EC Axial Fans

What control signals do LWAE3G fans accept?

0–10 V and PWM speed input, with tacho or alarm output; Modbus RTU is available on request. The wiring diagram on each model page shows the terminals.

How much energy does an EC axial fan save against AC?

About 30% at part load in typical condenser duty, more where the duty varies strongly; the saving depends on the load profile, so we confirm it against your operating hours.

Which EC axial sizes are three-phase?

Ø500, 550, 630, 710, 800 and 900 mm run on 380 / 400 V three-phase; Ø200–450 mm are 220 / 230 V single-phase.