ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCA-30920SN-06 LWCA-30920SN-06AC Ø30 mm 238 16 16 32 2,200 230 Details
LWCA-30986SN-06 LWCA-30986SN-06AC Ø30 mm 255 17 16 33 2,200 230 Details
LWCA-401055SN-06 LWCA-401055SN-06AC Ø40 mm 311 25 25 38 2,200 230 Details
LWCA-40150SN-07 LWCA-40150SN-07AC Ø40 mm 50 16 11 29 2,400 230 Details
LWCA-40150UN-06 LWCA-40150UN-06AC Ø40 mm 50 16 10 29 2,400 115 Details
LWCA-40190SN-07 LWCA-40190SN-07AC Ø40 mm 61 18 12 30 2,400 230 Details
LWCA-40190UN-06 LWCA-40190UN-06AC Ø40 mm 61 18 11 30 2,400 115 Details
LWCA-40250SN-07 LWCA-40250SN-07AC Ø40 mm 77 19 12 30 2,400 230 Details
LWCA-40250UN-06 LWCA-40250UN-06AC Ø40 mm 77 19 12 30 2,400 115 Details
LWCA-40290SN-07 LWCA-40290SN-07AC Ø40 mm 93 20 12 30 2,400 230 Details
LWCA-40290UN-06 LWCA-40290UN-06AC Ø40 mm 93 20 13 30 2,400 115 Details
LWCA-40350SN-07 LWCA-40350SN-07AC Ø40 mm 108 21 13 31 2,400 230 Details
LWCA-40350UN-06 LWCA-40350UN-06AC Ø40 mm 108 21 16 31 2,400 115 Details
LWCA-40420SN-07 LWCA-40420SN-07AC Ø40 mm 130 22 14 32 2,400 230 Details
LWCA-40420UN-06 LWCA-40420UN-06AC Ø40 mm 130 22 17 32 2,400 115 Details
LWCA-40530SN-06 LWCA-40530SN-06AC Ø40 mm 156 23 17 34 2,200 230 Details
LWCA-40610SN-06 LWCA-40610SN-06AC Ø40 mm 180 23 19 35 2,200 230 Details
LWCA-40700SN-06 LWCA-40700SN-06AC Ø40 mm 207 23 20 37 2,200 230 Details
LWCA-40800SN-06 LWCA-40800SN-06AC Ø40 mm 236 24 22 37 2,200 230 Details
LWCA-40854SN-06 LWCA-40854SN-06AC Ø40 mm 252 24 23 37 2,200 230 Details
LWCA-4090SN-07 LWCA-4090SN-07AC Ø40 mm 30 15 10 29 2,400 230 Details
LWCA-4090UN-06 LWCA-4090UN-06AC Ø40 mm 30 15 9 29 2,400 115 Details
LWCA-40920SN-06 LWCA-40920SN-06AC Ø40 mm 272 24 25 38 2,200 230 Details
LWCA-43150SN-07 LWCA-43150SN-07AC Ø43 mm 61 16 15 38 2,500 230 Details
LWCA-43150UN-06 LWCA-43150UN-06AC Ø43 mm 72 22 17 38 3,000 115 Details
LWCA-43190SN-07 LWCA-43190SN-07AC Ø43 mm 70 14 15 38 2,400 230 Details
LWCA-43190UN-06 LWCA-43190UN-06AC Ø43 mm 86 22 18 39 2,900 115 Details
LWCA-43250SN-07 LWCA-43250SN-07AC Ø43 mm 90 15 19 38 2,500 230 Details
LWCA-43250UN-06 LWCA-43250UN-06AC Ø43 mm 110 21 22 39 2,800 115 Details
LWCA-43290SN-07 LWCA-43290SN-07AC Ø43 mm 115 11 19 37 2,300 230 Details
LWCA-43290UN-06 LWCA-43290UN-06AC Ø43 mm 135 21 23 40 2,800 115 Details
LWCA-43350SN-07 LWCA-43350SN-07AC Ø43 mm 130 15 21 39 2,400 230 Details
LWCA-43350UN-06 LWCA-43350UN-06AC Ø43 mm 150 19 21 41 2,700 115 Details
LWCA-43420SN-07 LWCA-43420SN-07AC Ø43 mm 163 21 21 40 2,300 230 Details
LWCA-43420UN-06 LWCA-43420UN-06AC Ø43 mm 170 20 22 42 2,600 115 Details
LWCA-4390SN-07 LWCA-4390SN-07AC Ø43 mm 41 18 14 37 2,700 230 Details
LWCA-4390UN-06 LWCA-4390UN-06AC Ø43 mm 48 22 17 37 3,000 115 Details
LWCA-45120SN-06 LWCA-45120SN-06AC Ø45 mm 69 22 16 35 1,700 230 Details
LWCA-45120SN-07 LWCA-45120SN-07AC Ø45 mm 123 26 28 39 1,600 230 Details
LWCA-45180SN-06 LWCA-45180SN-06AC Ø45 mm 103 23 18 35 1,700 230 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

The Cross Flow Fans category currently lists 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure up to 320 Pa, on DC / AC / EC motors, across 236 series. Common voltages: 230 V, 24 V, 12 V, 115 V.

Cross flow (tangential) fans use a long cylindrical impeller that draws air in across its length and discharges it as an even, wide air curtain. Low noise, a slim envelope and a discharge that matches the width of the appliance make them the standard fan for indoor air-conditioning units, air curtains, elevators and linear air supply in appliances and electronics.

How to select a Cross Flow Fan

  1. Specify the impeller length and diameter from the housing you have — the discharge width must match the outlet.
  2. Cross flow fans develop low static pressure (typically below 100 Pa); design the air path with minimal resistance.
  3. Motor type follows the appliance: AC for mains-powered units, DC (12 / 24 / 48 V) for appliances and low-voltage equipment, EC where speed control and feedback are needed.
  4. Noise is dominated by tip speed — a longer impeller at lower speed is quieter than a short one at high speed for the same airflow.
  5. Confirm mounting direction and bearing side against the drawing; many lengths are made to order.

Typical applications

  • Indoor AC units and fan coil terminals
  • Air curtains and door air barriers
  • Elevator ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery cooling

Why specify LONGWELL cross flow fans

Every model here is a current production item with structured data — not a catalogue scan. Curves are tested on our own wind-tunnel rigs per AMCA 210 / ISO 5801 methods, drawings and datasheets download directly, CAD is released on request, and a quotation with the duty-point check comes back within one business day. Samples ship in 1–3 days and production batches in 15–30 days from the factory in Ningbo, with ISO 9001 / 14001 / 45001 management systems and ETL, CE and RoHS documentation per product line.

FAQs — Cross Flow Fans

How do I choose the length of a cross flow fan?

Match the impeller length to the discharge opening of your unit; airflow scales almost linearly with length at the same diameter and speed. Use the size buckets in this category or filter by diameter, then compare lengths within the series.

Can cross flow fans work against ducts?

Only against very low resistance. Static pressure capability is typically below 100 Pa, so they are used for free discharge or short, open air paths. For ducted duties choose an inline duct or centrifugal fan.

Are DC and EC cross flow fans speed controllable?

Yes. DC versions are controlled by voltage or PWM, EC versions by 0–10 V / PWM with tacho or fault feedback. AC versions can be supplied with tapped windings for two or three speeds.

What certifications do cross flow fans carry?

The DC cross flow range is ETL listed for North America (control number 5022563, UL 507 / CSA C22.2 No. 113); CE and RoHS documentation is available per model. See the certifications page for the scans.

Can you customise impeller length, shaft or connector?

Yes. Length, bearing side, shaft, lead-out and connector are configured to the appliance; samples ship in 1–3 days for standard lengths, custom lengths on request.