Cross Flow Fans

Filter by duty point318 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCD-43420LN-06 LWCD-43420LN-06DC Ø43 mm 191 16 3.84 43 2,400 12 Details
LWCD-43420MN-07 LWCD-43420MN-07DC Ø43 mm 191 16 4.08 43 2,400 24 Details
LWCD-4390LN-06 LWCD-4390LN-06DC Ø43 mm 44 12 1.44 36 2,400 12 Details
LWCD-4390MN-07 LWCD-4390MN-07DC Ø43 mm 44 12 1.68 36 2,400 24 Details
LWCD-45150MN-06 LWCD-45150MN-06DC Ø45 mm 83 22 5.04 37 2,000 24 Details
LWCD-45190MN-06 LWCD-45190MN-06DC Ø45 mm 105 22 6.48 37 2,000 24 Details
LWCD-45250MN-06 LWCD-45250MN-06DC Ø45 mm 138 23 7.2 38 2,000 24 Details
LWCD-45310MN-06 LWCD-45310MN-06DC Ø45 mm 172 24 8.4 41 2,000 24 Details
LWCD-45350MN-06 LWCD-45350MN-06DC Ø45 mm 194 24 9.12 42 2,000 24 Details
LWCD-45530MN-06 LWCD-45530MN-06DC Ø45 mm 277 28 11.76 44 2,000 24 Details
LWCD-45630MN-06 LWCD-45630MN-06DC Ø45 mm 329 28 16.8 45 2,000 24 Details
LWCD-45700MN-06 LWCD-45700MN-06DC Ø45 mm 365 28 20.4 46 2,000 24 Details
LWCD-45750MN-06 LWCD-45750MN-06DC Ø45 mm 392 28 22.56 46 2,000 24 Details
LWCD-45870MN-06 LWCD-45870MN-06DC Ø45 mm 454 26 19.2 47 2,000 24 Details
LWCD-4590MN-06 LWCD-4590MN-06DC Ø45 mm 50 21 4.08 37 2,000 24 Details
LWCD-50150LN-06 LWCD-50150LN-06DC Ø50 mm 88 38 2.4 37 2,000 12 Details
LWCD-50150MN-07 LWCD-50150MN-07DC Ø50 mm 88 38 2.4 37 2,000 24 Details
LWCD-50190LN-06 LWCD-50190LN-06DC Ø50 mm 110 36 3.36 38 2,000 12 Details
LWCD-50190MN-07 LWCD-50190MN-07DC Ø50 mm 110 36 3.36 38 2,000 24 Details
LWCD-50250LN-06 LWCD-50250LN-06DC Ø50 mm 139 34 4.32 39 2,000 12 Details
LWCD-50250MN-07 LWCD-50250MN-07DC Ø50 mm 139 34 4.32 39 2,000 24 Details
LWCD-50290LN-06 LWCD-50290LN-06DC Ø50 mm 161 30 5.28 40 2,000 12 Details
LWCD-50290MN-07 LWCD-50290MN-07DC Ø50 mm 161 30 5.28 40 2,000 24 Details
LWCD-50350LN-06 LWCD-50350LN-06DC Ø50 mm 198 26 6.24 41 2,000 12 Details
LWCD-50350MN-07 LWCD-50350MN-07DC Ø50 mm 198 26 6.24 41 2,000 24 Details
LWCD-50420LN-06 LWCD-50420LN-06DC Ø50 mm 232 20 7.2 42 2,000 12 Details
LWCD-50420MN-07 LWCD-50420MN-07DC Ø50 mm 232 20 7.2 42 2,000 24 Details
LWCD-50530MN-06 LWCD-50530MN-06DC Ø50 mm 288 21 7.92 43 2,000 24 Details
LWCD-50610MN-06 LWCD-50610MN-06DC Ø50 mm 332 19 8.88 42 2,000 24 Details
LWCD-50700MN-06 LWCD-50700MN-06DC Ø50 mm 381 20 9.84 43 2,000 24 Details
LWCD-5090LN-06 LWCD-5090LN-06DC Ø50 mm 54 40 1.68 37 2,000 12 Details
LWCD-5090MN-07 LWCD-5090MN-07DC Ø50 mm 54 40 1.68 37 2,000 24 Details
LWCD-601100MN-06 LWCD-601100MN-06DC Ø60 mm 857 34 31.2 51 1,800 24 Details
LWCD-60120LN-06 LWCD-60120LN-06DC Ø60 mm 102 27 8.16 38 2,000 12 Details
LWCD-60120MN-07 LWCD-60120MN-07DC Ø60 mm 102 27 8.4 38 2,000 24 Details
LWCD-601300MN-06 LWCD-601300MN-06DC Ø60 mm 1,012 35 32.64 52 1,800 24 Details
LWCD-60180LN-06 LWCD-60180LN-06DC Ø60 mm 152 29 9 38 2,000 12 Details
LWCD-60180MN-07 LWCD-60180MN-07DC Ø60 mm 152 29 9.6 38 2,000 24 Details
LWCD-60240LN-06 LWCD-60240LN-06DC Ø60 mm 203 32 1.32 39 2,000 12 Details
LWCD-60240MN-07 LWCD-60240MN-07DC Ø60 mm 203 32 10.08 39 2,000 24 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

Cross Flow Fans: 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure to 320 Pa, DC, AC and EC motors, across 236 series.

Cross flow (tangential) fans are specified by two numbers that both appear in the model code: impeller diameter and impeller length. LWCA-1501200 is a Ø150 mm impeller 1,200 mm long on an AC motor; LWCD is the 12 / 24 V DC line and LWCE the 230 V EC line. Diameters run from Ø30 to Ø150 mm and lengths from about 90 mm to 1,200 mm, all with aluminium-alloy impellers on maintenance-free ball bearings.

The discharge is a flat, even curtain as wide as the impeller, at low static pressure (8–320 Pa across the range). That makes the family the standard fan for indoor air-conditioner units, air curtains, elevator cabins, fireplaces and any appliance that needs a wide, quiet air stream from a slim housing.

How to select from this range

  1. Start from the housing: the impeller length must match the discharge opening, and the diameter is limited by the housing depth.
  2. Airflow scales almost linearly with length at a given diameter and speed, so a longer impeller at lower speed is the quiet way to reach a target airflow.
  3. Keep the air path open — cross flow fans develop little static pressure, so filters and grilles must be coarse.
  4. Pick the motor line by the appliance: LWCA for mains-powered units with two- or three-speed tapping, LWCD for battery or low-voltage designs with voltage / PWM control, LWCE for 230 V units that need stepless control and feedback.
  5. Confirm bearing side, shaft and lead-out position on the drawing; many combinations are made to order.

Where these fans are used

  • Indoor units of split and ducted air conditioners
  • Air curtains and door air barriers
  • Elevator cabin ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery-pack cooling

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cross Flow Fans

How do I read a cross flow fan model number?

LWCA-1501200SN-06: LWCA = AC line (LWCD = DC, LWCE = EC), 150 = impeller diameter in mm, 1200 = impeller length in mm, then the motor / mounting code and version. Compare models within the same diameter to trade length against speed.

What is the longest impeller you make?

Standard lengths in the catalogue reach 1,200 mm at Ø120–150 mm. Longer impellers are made with an intermediate bearing on request.

Can a cross flow fan work against a duct?

Only against very low resistance — typically below 100 Pa. For ducted duties choose an inline duct fan or a centrifugal blower; the selector will offer them if you enter a higher static pressure.

Which cross flow fans are ETL listed?

The DC cross flow line (LWCD, 12 / 24 / 48 V) is ETL listed under Intertek control no. 5022563 to UL 507 / CSA C22.2 No. 113. See the certificate scans on the R&D and certifications page.

Related selections

Scroll to Top
RFQ list