Cross Flow Fans

Filter by duty point318 models in this category

Filters use nameplate maximum values (max airflow at zero static pressure, max static pressure at zero airflow). Check the actual operating point on the performance curve of each model.

ModelSizeMax airflowm³/hMax static pressurePaPowerWNoisedB(A)SpeedrpmVoltageV
LWCD-30610MN-06 LWCD-30610MN-06DC Ø30 mm 158 18 3.12 33 2,400 24 Details
LWCD-30650MN-06 LWCD-30650MN-06DC Ø30 mm 168 18 3.12 34 2,400 24 Details
LWCD-30718MN-06 LWCD-30718MN-06DC Ø30 mm 185 19 3.36 35 2,400 24 Details
LWCD-30800MN-06 LWCD-30800MN-06DC Ø30 mm 207 19 1.32 36 2,400 24 Details
LWCD-30854MN-06 LWCD-30854MN-06DC Ø30 mm 221 20 4.56 36 2,400 24 Details
LWCD-3090LN-06 LWCD-3090LN-06DC Ø30 mm 27 12 1.08 26 3,300 12 Details
LWCD-3090MN-07 LWCD-3090MN-07DC Ø30 mm 27 12 0.96 26 3,300 24 Details
LWCD-30920MN-06 LWCD-30920MN-06DC Ø30 mm 238 20 5.04 37 2,400 24 Details
LWCD-30986MN-06 LWCD-30986MN-06DC Ø30 mm 255 21 5.28 37 2,400 24 Details
LWCD-401055MN-06 LWCD-401055MN-06DC Ø40 mm 311 27 8.4 36 2,000 24 Details
LWCD-40150LN-06 LWCD-40150LN-06DC Ø40 mm 55 21 1.68 33 2,400 12 Details
LWCD-40150MN-07 LWCD-40150MN-07DC Ø40 mm 55 21 1.92 33 2,400 24 Details
LWCD-40190LN-06 LWCD-40190LN-06DC Ø40 mm 69 22 1.92 34 2,400 12 Details
LWCD-40190MN-07 LWCD-40190MN-07DC Ø40 mm 69 22 2.16 34 2,400 24 Details
LWCD-40250LN-06 LWCD-40250LN-06DC Ø40 mm 87 23 2.16 35 2,400 12 Details
LWCD-40250MN-07 LWCD-40250MN-07DC Ø40 mm 87 23 2.64 35 2,400 24 Details
LWCD-40290LN-06 LWCD-40290LN-06DC Ø40 mm 104 24 2.4 35 2,400 12 Details
LWCD-40290MN-07 LWCD-40290MN-07DC Ø40 mm 104 24 3.12 35 2,400 24 Details
LWCD-40350LN-06 LWCD-40350LN-06DC Ø40 mm 121 24 2.88 36 2,400 12 Details
LWCD-40350MN-07 LWCD-40350MN-07DC Ø40 mm 121 24 3.6 36 2,400 24 Details
LWCD-40420LN-06 LWCD-40420LN-06DC Ø40 mm 146 25 3.48 37 2,400 12 Details
LWCD-40420MN-07 LWCD-40420MN-07DC Ø40 mm 146 25 4.08 37 2,400 24 Details
LWCD-40530MN-06 LWCD-40530MN-06DC Ø40 mm 176 25 4.56 37 2,400 24 Details
LWCD-40610MN-06 LWCD-40610MN-06DC Ø40 mm 203 26 5.04 37 2,400 24 Details
LWCD-40700MN-06 LWCD-40700MN-06DC Ø40 mm 232 26 5.52 38 2,400 24 Details
LWCD-40800MN-06 LWCD-40800MN-06DC Ø40 mm 236 25 6 35 2,000 24 Details
LWCD-40854MN-06 LWCD-40854MN-06DC Ø40 mm 252 26 6.72 35 2,000 24 Details
LWCD-4090LN-06 LWCD-4090LN-06DC Ø40 mm 34 20 1.44 33 2,400 12 Details
LWCD-4090MN-07 LWCD-4090MN-07DC Ø40 mm 34 20 1.44 33 2,400 24 Details
LWCD-40920MN-06 LWCD-40920MN-06DC Ø40 mm 272 26 7.44 36 2,000 24 Details
LWCD-43150LN-06 LWCD-43150LN-06DC Ø43 mm 73 12 2.2 37 2,400 12 Details
LWCD-43150MN-07 LWCD-43150MN-07DC Ø43 mm 73 12 2.4 37 2,400 24 Details
LWCD-43190LN-06 LWCD-43190LN-06DC Ø43 mm 90 13 2.4 39 2,400 12 Details
LWCD-43190MN-07 LWCD-43190MN-07DC Ø43 mm 90 13 2.88 39 2,400 24 Details
LWCD-43250LN-06 LWCD-43250LN-06DC Ø43 mm 113 14 2.76 40 2,400 12 Details
LWCD-43250MN-07 LWCD-43250MN-07DC Ø43 mm 113 14 3.12 40 2,400 24 Details
LWCD-43290LN-06 LWCD-43290LN-06DC Ø43 mm 136 14 3.12 41 2,400 12 Details
LWCD-43290MN-07 LWCD-43290MN-07DC Ø43 mm 136 14 3.36 41 2,400 24 Details
LWCD-43350LN-06 LWCD-43350LN-06DC Ø43 mm 158 15 3.48 41 2,400 12 Details
LWCD-43350MN-07 LWCD-43350MN-07DC Ø43 mm 158 15 3.84 41 2,400 24 Details
Certifications for this product line
ETL
View certificates →

Cross Flow Fans — selection guide

Cross Flow Fans: 318 models, impellers Ø30–150 mm, maximum airflow 23–4,000 m³/h, static pressure to 320 Pa, DC, AC and EC motors, across 236 series.

Cross flow (tangential) fans are specified by two numbers that both appear in the model code: impeller diameter and impeller length. LWCA-1501200 is a Ø150 mm impeller 1,200 mm long on an AC motor; LWCD is the 12 / 24 V DC line and LWCE the 230 V EC line. Diameters run from Ø30 to Ø150 mm and lengths from about 90 mm to 1,200 mm, all with aluminium-alloy impellers on maintenance-free ball bearings.

The discharge is a flat, even curtain as wide as the impeller, at low static pressure (8–320 Pa across the range). That makes the family the standard fan for indoor air-conditioner units, air curtains, elevator cabins, fireplaces and any appliance that needs a wide, quiet air stream from a slim housing.

How to select from this range

  1. Start from the housing: the impeller length must match the discharge opening, and the diameter is limited by the housing depth.
  2. Airflow scales almost linearly with length at a given diameter and speed, so a longer impeller at lower speed is the quiet way to reach a target airflow.
  3. Keep the air path open — cross flow fans develop little static pressure, so filters and grilles must be coarse.
  4. Pick the motor line by the appliance: LWCA for mains-powered units with two- or three-speed tapping, LWCD for battery or low-voltage designs with voltage / PWM control, LWCE for 230 V units that need stepless control and feedback.
  5. Confirm bearing side, shaft and lead-out position on the drawing; many combinations are made to order.

Where these fans are used

  • Indoor units of split and ducted air conditioners
  • Air curtains and door air barriers
  • Elevator cabin ventilation
  • Fireplaces, ovens and appliances
  • Cabinet and battery-pack cooling

Every figure above is measured on our own test rigs per AMCA 210 / ISO 5801 methods — see the test labs and certificates. Final selection is confirmed at the duty point and by project validation.

FAQ — Cross Flow Fans

How do I read a cross flow fan model number?

LWCA-1501200SN-06: LWCA = AC line (LWCD = DC, LWCE = EC), 150 = impeller diameter in mm, 1200 = impeller length in mm, then the motor / mounting code and version. Compare models within the same diameter to trade length against speed.

What is the longest impeller you make?

Standard lengths in the catalogue reach 1,200 mm at Ø120–150 mm. Longer impellers are made with an intermediate bearing on request.

Can a cross flow fan work against a duct?

Only against very low resistance — typically below 100 Pa. For ducted duties choose an inline duct fan or a centrifugal blower; the selector will offer them if you enter a higher static pressure.

Which cross flow fans are ETL listed?

The DC cross flow line (LWCD, 12 / 24 / 48 V) is ETL listed under Intertek control no. 5022563 to UL 507 / CSA C22.2 No. 113. See the certificate scans on the R&D and certifications page.