• ImpellerØ300 mm11.8 in
  • Max airflow1,906 m³/h1,122 CFM
  • Max static pressure112 Pa0.45 in. wg
  • Voltage220 V
  • Speed1,350 rpm
  • Input power85 W
  • Noise60 dB(A)

LWAA4E300S-5MEB-15 AC Axial Fan Ø300 mm

Ø300 mm | AC | Max airflow 1,906 m³/h | Max static pressure 112 Pa | 60 dB(A)

SKU: LWAA4E300S-5MEB-15 Categories: , ,
  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWAA4E300S-5MEB-154 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Dimensional drawing LWAA4E300S-5MEB-15

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWAA4E300S-5MEB-15 Dimensional drawing

Files for LWAA4E300S-5MEB-15: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWAA4E300S-5MEB-15

LWAA4E300S-5MEB-15 is a LONGWELL AC Axial Fan, impeller Ø300 mm, rated 220 V AC, maximum airflow 1,906 m³/h, maximum static pressure 112 Pa, noise 60 dB(A), input power 85 W.

Technical data

Model LWAA4E300S-5MEB-15
Series LWAA4E300
Motor type AC
Rated voltage 220 V
Frequency 50 Hz
Current 0.39 A
Input power 85 W
Speed 1,350 rpm
Max. airflow 1,906 m³/h
Max. static pressure 112 Pa
Noise 60 dB(A)
Impeller diameter Ø300 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWAA4E300S-5MEB-15

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same impeller (Ø300 mm · AC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWAA4E300S-5MEB-15 this model 1,906 m³/h112 Pa 1,350 rpm85 W60 dB(A)220 V
LWA-300(12")U(S)M-01 35 m³/hsee curve 1,350 rpm100 W—110-120 V View
LWA-300(12")U(S)M-02 46 m³/hsee curve 1,350 rpm120 W—110-120 V View
LWA-300(12")U(S)M-03 65 m³/hsee curve 2,800 rpm370 W—110-120 V View
LWAA4E300S-5MEW-15 1,906 m³/hsee curve 1,370 rpm85 W—220 V View
LWAA4E300S-5MKB-14 2,060 m³/hsee curve 1,600 rpm115 W55 dB(A)220/230 V View
LWEA300S(T)M-067E 2,280 m³/hsee curve 1,450 rpm180 W—220 V View
LWEAF300-01 2,280 m³/hsee curve 1,450 rpm180 W—220 V View
LWAA2E300S-5MEW-14 2,575 m³/hsee curve 2,300 rpm180 W60 dB(A)220 V View
LWAA2E300S-5MEB-14 2,606 m³/h124 Pa 2,350 rpm180 W69 dB(A)220 V View
LWA-300(12")U(S)M-04 3,000 m³/h230 Pa 2,800 rpm370 W—110-120 V View
LWAA2E300S-5MEW-07 3,090 m³/h391 Pa 2,750 rpm270 W72 dB(A)220 V View
LWAA2D300S-5MEW-05 3,090 m³/hsee curve 2,750 rpm270 W72 dB(A)380/400 V View
LWAA2D300S-5MEW-06 3,296 m³/hsee curve 3,100 rpm400 W73 dB(A)380/400 V View
LWAA2E300S-5MEW-08 3,502 m³/hsee curve 3,000 rpm400 W73 dB(A)220 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for axial fans — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote