Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.
- ImpellerØ450 mm17.7 in
- Max airflow6,386 m³/h3,759 CFM
- Max static pressure232 Pa0.93 in. wg
- Voltage220/230 V
- Speed1,600 rpm
- Input power445 W
- Noise68 dB(A)
LWAE3G450ST-5MEW-08 EC Axial Fan Ø450 mm
Ø450 mm | EC | Max airflow 6,386 m³/h | Max static pressure 232 Pa | 68 dB(A)
- Factory direct
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 18-month warranty
- CE · ETL · RoHS



Downloads for LWAE3G450ST-5MEW-08
PDFDatasheetNeed a non-standard size or another format? Ask an engineer or search the download center.
LWAE3G450ST-5MEW-08 is a LONGWELL EC Axial Fan from the EC Axial Fans range, impeller Ø450 mm, rated 220/230 V EC, maximum airflow 6,386 m³/h, maximum static pressure 232 Pa, noise 68 dB(A), input power 445 W. The EC motor integrates the drive electronics: stepless speed control by 0–10 V or PWM signal, speed feedback and high efficiency at part load.
Technical data
| Model | LWAE3G450ST-5MEW-08 |
|---|---|
| Series | LWAE3G450 |
| Motor type | EC |
| Phase | 1-phase |
| Rated voltage | 220/230 V |
| Voltage range | 176 ~ 264 V |
| Frequency | 50 Hz |
| Current | 2.15 A |
| Input power | 445 W |
| Speed | 1,600 rpm |
| Max. airflow | 6,386 m³/h |
| Max. static pressure | 232 Pa |
| Noise | 68 dB(A) |
| Ambient temperature | -25 ~ +60 ℃ |
| Storage temperature | -25 ~ 70℃ |
| Humidity | 0 ~ 85 % RH |
| Altitude | < 1000m |
| Impeller diameter | Ø450 mm |
| Impeller material | Sheet steel ( Impeller ) |
| Protection class | IP54 |
| Insulation class | B |
| Bearing | Maintenance-free ball bearings |
| Duty | S1 |
| Balance grade | G6.3 |
| Vibration standard | JB/T8689 |
| Service life | 40,000Hours(L10), At 40 °Croom, humidity 15%~65%RH |
Typical applications
- Condensers, evaporators and dry coolers
- Heat-pump and chiller outdoor units
- Building and workshop ventilation
- Cooling towers and transformer cooling
Series LWAE3G450: models in the same series share the impeller and motor platform and differ in speed grade, voltage or lead-out / terminal-box configuration — compare them in the table below or ask for the best fit at your duty point.
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Alternatives with the same impeller (Ø450 mm · EC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWAE3G450ST-5MEW-08 this model | 6,386 m³/h | 232 Pa | 1,600 rpm | 445 W | 68 dB(A) | 220/230 V | |
| LWBE3G450-138PT-12 | 5,329 m³/h | 452 Pa | 1,200 rpm | 386 W | — | 400 V | View |
| LWBE3G450-138PT-13 | 7,182 m³/h | 730 Pa | 1,610 rpm | 900 W | — | 400 V | View |
| LWBE3G450-188PT-07 | 7,425 m³/h | 1,568 Pa | 2,400 rpm | 1,590 W | — | 400 V | View |
| LWBE3G450-188NT-15 | 7,425 m³/h | 1,568 Pa | 2,400 rpm | 1,590 W | 70 dB(A) | 400 V | View |
| LWFE3G450-102PS-11 | 7,467.5 m³/h | 1,030 Pa | 1,450 rpm | 700 W | 70 dB(A) | 230 V | View |
| LWBE3G450-138PT-04 | 7,828 m³/h | 824 Pa | 1,720 rpm | 910 W | 79 dB(A) | 400 V | View |
| LWBE3G450-188PT-08 | 8,019 m³/h | 1,802 Pa | 2,600 rpm | 2,060 W | — | 400 V | View |
| LWBE3G450-188NT-16 | 8,019 m³/h | 1,802 Pa | 2,600 rpm | 2,060 W | 74 dB(A) | 400 V | View |
| LWFE3G450-102PT-06 | 8,652 m³/h | 1,390.5 Pa | 1,500 rpm | 1,100 W | 85 dB(A) | 400 V | View |
| LWBE3G450-188PT-09 | 8,661 m³/h | 2,114 Pa | 2,800 rpm | 2,595 W | — | 400 V | View |
| LWBE3G450-188NT-17 | 8,661 m³/h | 2,114 Pa | 2,800 rpm | 2,595 W | 85 dB(A) | 400 V | View |
| LWBE3G450-188PT-16 | 8,985 m³/h | 840 Pa | 2,600 rpm | 2,400 W | — | 400 V | View |
| LWBE3G450-188NT-22 | 10,752 m³/h | 1,669 Pa | 2,400 rpm | 2,400 W | 92 dB(A) | 380 V | View |
| LWBE3G450-188NT-21 | 12,647 m³/h | 2,342 Pa | 2,800 rpm | 4,600 W | 96 dB(A) | 380 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Other models in the LWAE3G450 seriesSame impeller, different speed grade or wiring
LWAE3G450SS-5MEW-03Ø450 mm · 6,695 m³/h · 242 Pa · ECsame series
LWAE3G450SS-5MEW-07Ø450 mm · 6,386 m³/h · 232 Pa · ECsame series
LWAE3G450SS-5MEW-09Ø450 mm · 5,871 m³/h · 163 Pa · ECsame series
LWAE3G450SS-5MGW-05Ø450 mm · 6,695 m³/h · 242 Pa · ECsame series
LWAE3G450SS-5MNW-01Ø450 mm · 6,695 m³/h · 242 Pa · ECsame series
LWAE3G450ST-5MEW-04Ø450 mm · 6,695 m³/h · 242 Pa · ECsame seriesAdjacent sizesOne size up when airflow is short, one size down when it is too much
LWAA4D420S-5MEB-03Ø420 mm · 5,459 m³/h · ACadjacent size
LWAA4E420S-5MEB-02Ø420 mm · 5,974 m³/h · ACadjacent size
LWAA4D420S-5MEB-04Ø420 mm · 5,974 m³/h · ACadjacent size
LWAA4E420S-5MEB-01Ø420 mm · 5,459 m³/h · ACadjacent size
LWA-500S(T)M-03EØ490 mm · 6,800 m³/h · 185 Pa · ACadjacent size
LWAE3G400SS-5MEW-03Ø400 mm · 4,944 m³/h · 208 Pa · ECadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
See all Axial Fans · select by duty point
























