• ImpellerØ250 mm9.8 in
  • Max airflow300 m³/h177 CFM
  • Max static pressure102 Pa0.41 in. wg
  • Voltage220-50 V
  • Speed1,140 rpm
  • Input power40 W
  • Noise54 dB(A)

LWDA250S-F02 Rectangular Inline Centrifugal Duct Fan Ø250 mm

Ø250 mm | AC | Max airflow 300 m³/h | Max static pressure 102 Pa | 54 dB(A)

  • Direct from LONGWELL
  • OEM / ODM
  • Samples in 1–3 days
  • Production 15–30 days
  • 12-month warranty
  • CE · RoHS · ETL on request
All files for LWDA250S-F022 files · direct download

CAD models (STEP / DWG) are released on request — see “Engineering files” below. Another format or a non-standard variant? Ask an engineer · download center

View RFQ →

Video LWDA250S-F02

LWDA-250 Fan Test | LWDA-250(10″)S-MWN-06 · open in video library

Dimensional drawing LWDA250S-F02

Dimensional drawingDimensions in mm. Confirm against the final approval drawing before machining cut-outs.
LWDA250S-F02 Dimensional drawing

Files for LWDA250S-F02: datasheet, catalogue and drawing PDFs are listed above ↑ · CAD (STEP / DWG) on request — ask an engineer.

Technical description LWDA250S-F02

LWDA250S-F02 is a LONGWELL Rectangular Inline Centrifugal Duct Fan, impeller Ø250 mm, rated 220-50 V AC, maximum airflow 300 m³/h, maximum static pressure 102 Pa, noise 54 dB(A), input power 40 W.

Technical data

Model LWDA250S-F02
Series LWDA250
Motor type AC
Rated voltage 220-50 V
Current 0.18 A
Input power 40 W
Speed 1,140 rpm
Max. airflow 300 m³/h
Max. static pressure 102 Pa
Noise 54 dB(A)
Impeller diameter Ø250 mm

Nameplate values; final selection is confirmed at the duty point and by project verification.

Company certificates

Scans of original documents held by Ningbo Longwell Electric Technology Co., Ltd.: the company ISO 9001 / 14001 / 45001 management-system certificate. Click a scan to open the original.

ISO 9001 / 14001 / 45001Management systems of Ningbo Longwell Electric Technology Co., Ltd. (company certificate).

ISO 9001 / 14001 / 45001 management system certificate — LONGWELL certificatePDFISO 9001 / 14001 / 45001 management system certificate

Need a Declaration of Conformity for this model and your destination market? Ask us — we arrange additional certification on request.

How to order LWDA250S-F02

Most first orders follow the same eight steps. Quantities, terms and lead times are confirmed in your quotation.

  1. 1SelectFind models by duty point in the selector or by model number, compare on the curve and add them to your RFQ list.
  2. 2Engineering checkWithin 1 business day you receive the duty-point check on the curve, price and lead time.
  3. 3SamplesStock models ship in 1–3 days.
  4. 4Validation supportDatasheets, drawings, wiring diagrams and DoC per model; test reports, CAD and register maps after a short project check or NDA.
  5. 5Order & paymentProforma invoice; first orders on T/T 30 / 70.
  6. 6Production & release15–30 days at the partner factory that builds your model, then inspected and released to LONGWELL standards with outgoing sampling to AQL 2.5.
  7. 7ShippingFOB / CIF / DDP by sea from Ningbo or Shanghai; express and air on EXW / FCA / DAP.
  8. 8After-sales12 months standard, extendable to 18–24 months by project agreement; test records retained for 5 years; 8D closed-loop for any issue; annual technical review for framework customers.

See terms, QC and FAQ →

Test & release at LONGWELL

Specified and drawn by LONGWELL; built to LONGWELL drawings by qualified partner factories; inspected and released to LONGWELL standards before shipment.

See test and release photos (8)
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Semi-anechoic chamber
Semi-anechoic chamber
LONGWELL Test laboratory
Test laboratory
LONGWELL Test laboratory
Test laboratory
LONGWELL Burn-in test
Burn-in test
LONGWELL Burn-in test
Burn-in test
LONGWELL Inspection
Inspection
LONGWELL Warehouse
Warehouse

Test labs and all certificate scans →

Alternatives with the same impeller (Ø250 mm · AC)

Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.

ModelMax airflowMax static pressureSpeedPowerNoiseVoltage
LWDA250S-F02 this model 300 m³/h102 Pa 1,140 rpm40 W54 dB(A)220-50 V
LWDA250S-F01 430 m³/h305 Pa 1,570 rpm85 W64 dB(A)220-50 V View
LWDA250S-B01 500 m³/h330 Pa 2,300 rpm65 W61 dB(A)220-50 V View
LWDA-250S-MBN-11 1,030 m³/h587 Pa 2,600 rpm190 W51 dB(A)230 V View
LWDA-250S-MBN-10 1,034 m³/h515 Pa 2,615 rpm165 W71 dB(A)230 V View
LWDA-250 (10")U-MWN-01 1,219 m³/hsee curve 3,000 rpm228 W69 dB(A)110-120 V View
LWDA-250 (10")U-MWN-03 1,219 m³/hsee curve 3,000 rpm228 W62 dB(A)110-120 V View
LWDA-250(8'')S-PWN-05 1,600 m³/h420 Pa 2,500 rpm175 W50 dB(A)230 V View
LWDA-250(10")S-PBN-002S 1,854 m³/h503 Pa 2,600 rpm245 W50 dB(A)220 V View
LWDA-250(10")S-PBN-002 1,854 m³/h503 Pa 2,600 rpm245 W50 dB(A)220 V View
LWDA-250 (10")S-MWN-02 1,900 m³/hsee curve 2,750 rpm162 W68 dB(A)220-240 V View
LWDA-250 (10")S-MWN-04 1,900 m³/hsee curve 2,750 rpm162 W60 dB(A)220-240 V View
LWDA-250(10")S-MWN-06 2,100 m³/h215 Pa 2,800 rpm100 W65 dB(A)220 V View

Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.

Go deeper on longwellfans.com

Application guides, project stories and engineering calculators for inline duct fans — on our main site.

Ningbo Longwell Electric Technology Co., Ltd. · No. 100 Henan Road, Ditang, Yuyao, Ningbo, Chinasales@longwellfans.com · WhatsApp +86 183 5827 4663 · Mon–Fri 8:30–17:30 (UTC+8), reply within 1 business dayHow to order · Privacy notice
Scroll to Top
WhatsApp Email sales
Get a quote