Digitised from the catalogue curve at standard air (20 °C, 101.3 kPa, 1.2 kg/m³); one curve per voltage / speed grade. The system resistance curve depends on the actual ductwork — confirm the operating point on site. Need an engineer to verify the duty point? Contact us or add the model to your RFQ and note the duty point.
- ImpellerØ500 mm19.7 in
- Max airflow11,000 m³/h6,474 CFM
- Max static pressure910 Pa3.65 in. wg
- Noise82 dB(A)
LWFA-E-500-02 LWFA Series Direct Drive Centrifugal Blower Ø500 mm
Ø500 mm | AC | Max airflow 11,000 m³/h | Max static pressure 910 Pa | 82 dB(A)
- Factory direct
- OEM / ODM
- Samples in 1–3 days
- Production 15–30 days
- 18-month warranty
- CE · ETL · RoHS

Series catalogue
PDFLWFA LWFA Series Direct Driven centrifugal blower · 1.4 MBCovers the whole series, not only this model.
Need a non-standard size or another format? Ask an engineer or search the download center.
LWFA-E-500-02 is a LONGWELL LWFA Series Direct Drive Centrifugal Blower from the Impeller Ø280–500 mm range, impeller Ø500 mm, maximum airflow 11,000 m³/h, maximum static pressure 910 Pa, noise 82 dB(A). The fixed-speed AC external-rotor motor is simple, robust and cost-effective for constant-duty applications.
Technical data
| Model | LWFA-E-500-02 |
|---|---|
| Motor type | AC |
| Max. airflow | 11,000 m³/h |
| Max. static pressure | 910 Pa |
| Noise | 82 dB(A) |
| Impeller diameter | Ø500 mm |
| Blade diameter | 500mm |
Typical applications
- Commercial kitchen extraction
- Ventilation units and AHUs
- Process and fume extraction
Nameplate values: maximum airflow is measured at zero static pressure and maximum static pressure at zero airflow; the two never occur together. Confirm the operating point on the performance curve. Final selection is subject to the duty point (airflow / static pressure / voltage / control mode) and project verification.
Alternatives with the same impeller (Ø500 mm · AC)
Same impeller, different speed grade, power or wiring. Step up for more airflow, step down for lower noise.
| Model | Max airflow | Max static pressure | Speed | Power | Noise | Voltage | |
|---|---|---|---|---|---|---|---|
| LWFA-E-500-02 this model | 11,000 m³/h | 910 Pa | — | — | 82 dB(A) | — | |
| LWA-500(20")U(S)M-01 | 150 m³/h | see curve | 1,350 rpm | 200 W | — | 110-120 V | View |
| LWA-500(20")U(S)M-02 | 165 m³/h | see curve | 1,350 rpm | 250 W | — | 110-120 V | View |
| LWBA6D500-138NT-03 | 5,356 m³/h | 361 Pa | 950 rpm | 450 W | 63 dB(A) | 380 V | View |
| LWEA500S(T)M-069E | 5,700 m³/h | see curve | 1,450 rpm | 550 W | — | 220 V | View |
| LWEAF500-01 | 5,700 m³/h | see curve | 1,450 rpm | 550 W | — | 220 V | View |
| LWBA6D500-138NT-04 | 5,817 m³/h | 412 Pa | 1,050 rpm | 550 W | 65 dB(A) | 380 V | View |
| LWMFAF500-01 | 7,800 m³/h | 2,250 Pa | — | — | 91 dB(A) | 380 V | View |
| LWBA4D500-188NT-01 | 8,034 m³/h | 618 Pa | 1,350 rpm | 1,000 W | 79 dB(A) | 380 V | View |
| LWFA-E-500-01 | 8,380 m³/h | 850 Pa | — | — | 75 dB(A) | — | View |
| LWFA6D500-188NT-01 | 9,064 m³/h | 916.7 Pa | 900 rpm | 4,400 W | 75 dB(A) | 380 V | View |
| LWEA500TM-164E | 9,133 m³/h | 185 Pa | 1,450 rpm | 750 W | — | 380 V | View |
| LWAA4D500S-7MKB-11 | 9,270 m³/h | see curve | 1,350 rpm | 800 W | 80 dB(A) | 380/400 V | View |
| LWBA4D500-188NT-05 | 9,377 m³/h | 872 Pa | 1,350 rpm | 1,300 W | 81.9 dB(A) | 380 V | View |
| LWBA4D500-188NT-02 | 9,785 m³/h | 773 Pa | 1,400 rpm | 1,500 W | 80 dB(A) | 380 V | View |
Not sure which one? Send us the duty point (airflow / static pressure / noise limit) — use the selector or ask an engineer.
Adjacent sizesOne size up when airflow is short, one size down when it is too much
LWFA-E-450-02Ø450 mm · 10,500 m³/h · 750 Pa · ACadjacent size
LWFA-E-450-01Ø450 mm · 6,230 m³/h · 710 Pa · ACadjacent size
LWFA-E-400-01Ø400 mm · 4,500 m³/h · 612 Pa · ACadjacent size
LWFA-E-400-02Ø400 mm · 5,100 m³/h · 610 Pa · ACadjacent size
LWFA-E-350-01Ø350 mm · 2,950 m³/h · 370 Pa · ACadjacent size
LWDD12-12-ECØ305 mm · 1,489 m³/h · 437 Pa · ECadjacent sizeAlternatives at a similar dutySimilar airflow, different construction or motor platform
See all Commercial Centrifugal Blowers · select by duty point